Interpretation of Positive Flow Cytometric Crossmatch in the Era of the Single-Antigen Bead Assay

被引:78
|
作者
Couzi, Lionel [1 ,2 ,3 ]
Araujo, Caroline [1 ]
Guidicelli, Gwendaline [1 ]
Bachelet, Thomas [1 ]
Moreau, Karine [1 ]
Morel, Delphine [1 ]
Robert, Gregoire [1 ,3 ]
Wallerand, Herve [1 ,3 ]
Moreau, Jean-Francois [1 ,2 ,3 ]
Taupin, Jean-Luc [1 ,2 ,3 ]
Merville, Pierre [1 ,2 ,3 ]
机构
[1] Hop Pellegrin, CHU Bordeaux, F-33076 Bordeaux, France
[2] CNRS, UMR 5164, Bordeaux, France
[3] Univ Bordeaux 2, F-33076 Bordeaux, France
关键词
DSA; Crossmatch; Acute rejection; Kidney transplantation; DONOR-SPECIFIC ANTIBODIES; KIDNEY-TRANSPLANT PATIENTS; HIGHLY SENSITIZED PATIENTS; RENAL-TRANSPLANTATION; CLINICAL-RELEVANCE; MEDIATED REJECTION; HLA ANTIBODIES; DESENSITIZATION; ALLOANTIBODIES; IMMUNOGLOBULIN;
D O I
10.1097/TP.0b013e31820794bb
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Prognosis of renal transplants with positive flow cytometric crossmatch (FCXM) remains controversial. Methods. We analyzed the outcome of these kidney transplant recipients by human leukocyte antigen (HLA) donor-specific antibodies (HLA-DSA) using single-antigen bead (SAB) assays in major histocompatibility complex classes I and II. We compared them with controls with a negative FCXM. Results. Forty-five patients consecutively transplanted with a positive FCXM had significantly more acute rejection episodes than the control patients (33.3% vs. 8.9%, P = 0.002). Risk of acute rejection was increased with day 0 (D0) positive T-cell FCXM (odds ratio [OR] = 9.04, P = 0.002), D0 positive B-cell FCXM (OR = 7.43, P = 0.02), and D0 HLA-DSA identified by SAB assay (OR = 6.5, P = 0.03). The 21 patients with D0 positive FCXM and D0 HLA-DSA had more acute rejection (62%, P = 0.0001) and a lower estimated glomerular filtration rate 1-year posttransplantation (P = 0.0001), when compared with controls. Mainly anti-Cw and anti-DP HLA-DSA were found in patients displaying acute rejection. The remaining FCXM-positive patients displayed short-term outcomes similar to controls. The presence of HLA-DSA detected only by the SAB assay in the context of a negative FCXM crossmatch was not associated with increased risk of acute rejection. Conclusion. Identification of HLA-DSA in D0 sera by the two sensitive techniques FCXM and SAB assay indicates which patients are at highest risk of subsequent acute allograft rejection and chronic allograft dysfunction.
引用
收藏
页码:527 / 535
页数:9
相关论文
共 50 条
  • [1] Interpretation of Positive Flow Cytometric Crossmatch in the Era of Single Antigen Flow Bead Analysis.
    Couzi, Lionel
    Araujo, Caroline
    Guidicelli, Gwendaline
    Bachelet, Thomas
    Moreau, Jean-Francois
    Taupin, Jean-Luc
    Merville, Pierre
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2010, 10 : 238 - 238
  • [2] Interpretation of positive flow cytometric crossmatch in the era of HLA-donor specific antibodies by single antigen flow bead analysis
    Couzi, Lionel
    Araujo, Caroline
    Guidicelli, Line-Gwenda
    Bachelet, Thomas
    Moreau, Karine
    Morel, Delphine
    Robert, Gregoire
    Wallerand, Herve
    Moreau, Jean-Francois
    Merville, Pierre
    Taupin, Jean-Luc
    [J]. TISSUE ANTIGENS, 2010, 75 (05): : 587 - 587
  • [3] Positive single-antigen bead assay with negative flow crossmatch in a renal transplant-A case report
    Mishra, Vikash Chandra
    Chandra, Dinesh
    Anthwal, Archana
    Bhardwaj, Amit Kr
    Raina, Vimarsh
    [J]. INDIAN JOURNAL OF TRANSPLANTATION, 2022, 16 (04) : 425 - 427
  • [4] SINGLE-ANTIGEN BEAD ANALYSIS: A HIGHLY ACCURATE PREDICTOR OF THE OUTCOME & STRENGTH OF THE FLOW CYTOMETRIC CROSSMATCH
    Jaramillo, Andres
    Labuda, Bozena
    Turon, John
    Freedom, David
    Magas, Daniel
    [J]. HUMAN IMMUNOLOGY, 2009, 70 : S27 - S27
  • [5] The CDC crossmatch in the era of flow cytometric crossmatch and single antigen beads
    Mahowald, Grace Kao
    [J]. JORNAL BRASILEIRO DE NEFROLOGIA, 2021, 43 (03): : 299 - 300
  • [6] Predicting flow cytometry crossmatch results from single-antigen bead testing
    Flynn, Patrick A.
    Fernando, Sebastian
    Worthington, Judith E.
    Poulton, Kay V.
    [J]. INTERNATIONAL JOURNAL OF IMMUNOGENETICS, 2024, 51 (02) : 93 - 99
  • [7] Luminex single-antigen beads: a highly accurate tool to predict the outcome & strength of the flow cytometric crossmatch (virtual crossmatch)
    Jaramillo, Andres
    Labuda, Bozena
    Turon, John
    Freedom, David
    Magas, Daniel
    [J]. TISSUE ANTIGENS, 2010, 75 (05): : 572 - 572
  • [8] The virtual crossmatch: Prediction of the results of the flow cytometry crossmatch from the single antigen bead assay
    Spells, Kim
    Rogers, James
    Nottingham, Kelly
    Stastny, Peter
    [J]. HUMAN IMMUNOLOGY, 2006, 67 (10) : S71 - S71
  • [9] PREDICATION OF POSITIVE FLOW CROSSMATCH BY USING MEAN FLUORESCENCE INTENSITY OF LUMINEX SINGLE ANTIGEN BEAD ASSAY
    Wan, Liang
    Wegner, Wendy E.
    Chen, Dong-Feng
    [J]. HUMAN IMMUNOLOGY, 2013, 74 (05) : 495 - 495
  • [10] Platelet Crossmatch and Single-Antigen Bead Results Correlate: Support for Antigen-Negative Platelet Selection
    Kreuter, J.
    Duellman, P.
    DeGoey, S.
    Stubbs, J. R.
    Gandhi, M. J.
    [J]. TRANSFUSION, 2014, 54 : 222A - 222A