Dynamics of single cell property distributions in Chinese hamster ovary cell cultures monitored and controlled with automated flow cytometry

被引:24
|
作者
Kacmar, J
Srienc, F
机构
[1] Univ Minnesota, Dept Chem Engn & Mat Sci, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Biotechnol Inst, Gortner Lab 240, St Paul, MN 55108 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
automated flow cytometry; bioreactor controls; bioreactor monitoring; cytostat; mammalian cell culture; single cell heterogeneity;
D O I
10.1016/j.jbiotec.2005.06.031
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Two important variables that are often not measured online in Chinese hamster ovary (CHO) cell cultures are cell number concentration and culture viability. We have developed an automated flow cytometry system that measured the cell number concentration, single cell viability based on propidium iodide (PI) exclusion, and single cell light scattering from bioreactor samples every 30 min. The bioreactor was monitored during batch growth, and then the cell number concentration was controlled at a set point during cytostat operation. NH4Cl was added during steady state operation in cytostat mode to monitor the transient cell population response to adverse growth conditions. The automated measurements correlated well to cell concentration and viability determined manually using a hemacytometer. The described system provides a method to study mammalian cell culture physiology and dynamics in great detail. It presents a new method for the monitoring and control of animal cell culture. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:410 / 420
页数:11
相关论文
共 50 条
  • [1] Application of Imaging Flow Cytometry for the Characterization of Intracellular Attributes in Chinese Hamster Ovary Cell Lines at the Single-Cell Level
    Pekle, Eva
    Smith, Andrew
    Rosignoli, Guglielmo
    Sellick, Christopher
    Smales, C. M.
    Pearce, Claire
    BIOTECHNOLOGY JOURNAL, 2019, 14 (07)
  • [2] Growth dynamics of mammalian cells monitored with automated cell cycle staining and flow cytometry
    Sitton, Greg
    Srienc, Friedrich
    CYTOMETRY PART A, 2008, 73A (06) : 538 - 545
  • [3] Characterization of cell cycle and apoptosis in Chinese hamster ovary cell culture using flow cytometry for bioprocess monitoring
    Ji, Xiaodan
    Lee, Young Je
    Eyster, Tom
    Parrillo, Alexis
    Galosy, Sybille
    Ao, Zhaohui
    Patel, Pramthesh
    Zhu, Yuan
    BIOTECHNOLOGY PROGRESS, 2022, 38 (01)
  • [4] Calibration of the single cell gel electrophoresis assay, flow cytometry analysis and forward mutation in Chinese hamster ovary cells
    Wagner, ED
    Rayburn, AL
    Anderson, D
    Plewa, MJ
    MUTAGENESIS, 1998, 13 (01) : 81 - 84
  • [5] Automated flow cytometry for monitoring CHO cell cultures
    Kuystermans, Darrin
    Mohd, Avesh
    Al-Rubeai, Mohamed
    METHODS, 2012, 56 (03) : 358 - 365
  • [7] Analysis of mutagens with single cell gel electrophoresis, flow cytometry, and forward mutation assays in an isolated clone of Chinese hamster ovary cells
    Wagner, ED
    Rayburn, AL
    Anderson, D
    Plewa, MJ
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 1998, 32 (04) : 360 - 368
  • [8] BIOT 153-Scale-up of mammalian cell cultures controlled by automated flow cytometry
    Sitton, Greg
    Srienc, F.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [9] A mechanistic study on the effect of dexamethasone in moderating cell death in Chinese Hamster Ovary cell cultures
    Jing, Ying
    Qian, Yueming
    Ghandi, Mahmoud
    He, Aiqing
    Borys, Michael C.
    Pan, Shih-Hsie
    Li, Zheng Jian
    BIOTECHNOLOGY PROGRESS, 2012, 28 (02) : 490 - 496
  • [10] Solvation Dynamics and Intermittent Oscillation of Cell Membrane: Live Chinese Hamster Ovary Cell
    Ghosh, Shirsendu
    Chattoraj, Shyamtanu
    Bhattacharyya, Kankan
    JOURNAL OF PHYSICAL CHEMISTRY B, 2014, 118 (11): : 2949 - 2956