Investigation of an efficient source design for Cobalt-60-based tomotherapy using EGSnrc Monte Carlo simulations

被引:16
|
作者
Joshi, Chandra P. [1 ,2 ,3 ]
Darko, Johnson [1 ,2 ]
Vidyasagar, P. B. [3 ]
Schreiner, L. John [1 ,2 ]
机构
[1] Kingston Gen Hosp, Canc Ctr S Eastern Ontario, Kingston, ON K7L 5P9, Canada
[2] Queens Univ, Kingston, ON, Canada
[3] Univ Poona, Dept Phys, Pune 411007, Maharashtra, India
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 03期
关键词
D O I
10.1088/0031-9155/53/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent investigations demonstrate a strong potential for Cobalt-60 (Co-60)-based tomotherapy. Reported work suggests that Co-60-based tomotherapy offers a clinically and commercially viable alternative to megavoltage x-ray-based tomotherapy. Tomotherapy applications use a combination of intensity-modulated fan beams to deliver highly conformal radiotherapy. However, conventional Co-60 units are designed to give large uniform rectangular fields using an isotropic radioactive source in a cylindrical geometry. Such cylindrical source geometry likely provides a sub-optimal use of the radioactivity within the source volume for tomotherapy applications due to a significant loss of radiated energy outside the fan beam collimation system. To investigate a more efficient source geometry suitable for Co-60 tomotherapy applications, a computer code was written tomodel an isotropic source in a 6-faced polyhedron geometry such as cube, parallelepiped, prism and truncated pyramid. This code was integrated with the existing EGSnrc/BEAMnrc Monte Carlo (MC) code. The integrated source code was thoroughly tested, validated and used to investigate the energy spectra, radiation output and self-shielding properties of various rectangular-shaped (RS) Co-60 sources. Fan beam dose profiles were calculated for various cylindrical and RS Co-60 sources for a range of source-to-axis distances (SAD), multi-leaf collimator-to-isocentre distances (CID) and modified collimator systems. Fringe and penumbra distances were analysed for the simulated dose profiles. Our results demonstrate that clinically acceptable fringe and penumbra distances can be achieved by a careful selection of SAD, CID, source shape and dimensions and modified collimator system. Significant overall gain in radiation output of the 20 x 1 cm(2) fan beams can be achieved by an optimal selection of the source geometry for a given active volume of Co-60. The overall gain includes the effects of change in packing density (accounting for self-absorption) and change in source shape.
引用
收藏
页码:575 / 592
页数:18
相关论文
共 50 条
  • [1] Monte Carlo Simulation for the Radixact™ Tomotherapy Linac Using EGSnrc
    Makrani, Danial Seifi
    Nedaei, Hassan Ali
    Geraily, Ghazale
    Khorami-Moghaddam, Alireza
    Banaee, Nooshin
    Jassim, Hussam
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 379 - 386
  • [2] Validation of a Virtual Source Model for Monte Carlo Simulations of Tomotherapy
    Yuan, J.
    Chen, Q.
    Yao, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S688 - S688
  • [3] Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations
    Cecen, Yigit
    Yazgan, Cagri
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [4] Monte Carlo simulations of complex geometries and an optimal 60cobalt source design using the integrated TIGER series (ITS 3.0)
    Mohamed, AB
    Silverman, J
    Weiss, DE
    Al-Sheikhly, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 243 (02): : 359 - 370
  • [5] Experimental Validation of Monte Carlo Simulations Based on a Virtual Source Model for Tomotherapy in a Rando Phantom
    Yuan, J.
    Albani, D.
    Zheng, Y.
    Wessels, B. W.
    Lo, S. S.
    Yao, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E608 - E608
  • [6] Experimental Validation of Monte Carlo Simulations Based on a Virtual Source Model for TomoTherapy in a RANDO Phantom
    Yuan, Jiankui
    Zheng, Yiran
    Wessels, Barry
    Lo, Simon S.
    Ellis, Rodney
    Machtay, Mitchell
    Yao, Min
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : 796 - 804
  • [7] A method of CBCT imaging scatter correction based on the EGSnrc monte carlo simulations
    Meng, H. P.
    Dong, H. J.
    Wang, K. Q.
    Feng, Y. M.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 21 - 22
  • [8] Dose Perturbations at Heterogeneous Interfaces in Radiotherapy - an EGSnrc based Monte Carlo Investigation
    Ahmad, Muhammad Adeel
    Ahmed, Shahbaz
    Kakakhel, Muhammad Basim
    Rehman, Shakeel Ur
    Mirza, Sikander M.
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [9] Monte Carlo study of an electronic brachytherapy source using MCNP5 and EGSnrc
    Davis, S.
    DeWerd, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2472 - 2473
  • [10] 4D Monte Carlo Simulations of Beam and Patient Motion Using EGSnrc/BEAMnrc
    Heath, E.
    Badragan, I.
    Popescu, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3921 - 3921