Test-retest reliability of 24 hours of activity monitoring in individuals with Parkinson's disease in home and community

被引:29
|
作者
White, Daniel K.
Wagenaar, Robert C.
Del Olmo, Mary E.
Ellis, Terry D.
机构
[1] Boston Univ, Sargent Coll Hlth & Rehabil Sci, Dept Phys Therapy & Athlet Training, Ctr Neurorehabil, Boston, MA 02215 USA
[2] Boston Univ, Sargent Coll Hlth & Rehabil Sci, Program Rehabil Sci ScD, Boston, MA 02215 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
activity monitoring; Parkinson's disease; physical activities; accelerometry;
D O I
10.1177/1545968306297867
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background/Objective. This study examined the test-retest reliability of an activity monitor (AM) in home and community settings in individuals with Parkinson's disease (PD). Methods. Nine independent community dwellers with idiopathic PD were recruited (8 males and 1 female; median age = 66 years, range 46-71; Hoehn & Yahr score 2). Patients wore the AM for 3 separate sessions in the home and community with 7 days between each session. The first 2 sessions lasted 24 hours each, and the third session lasted 48 hours. Reliability indices and measures of variability were obtained by using intraclass correlation coefficients (ICC) and generalizability coefficients. The functional activity measures included the percentage of time spent in sleeping positions, sitting, standing, and walking; the number of transitions between sit and stand; the total number of transitions; the number of walking periods lasting 5 and 10 seconds; and stride frequency. Results. The ICCs for functional activities between the first and second consecutive days for the 48-hour session (third session) ranged from .76 to .92. The ICCs for the 7- and 14-day intervals ranged from .45 to .96, with walking-related measures showing the highest ICCs (range = .81 to.96). Across the three 24-hour periods (sessions 1 and 2, and the First 24 hours of session 3), the ICCs for walking-related measures were again high ranging from.87 to.92. Walking-related measures demonstrated the highest generalizability coefficients, indicating these measures have the highest test-retest reliability in comparison to other functional activity measures. Conclusions. The present study shows that 24 hours of recording with an AM is a sufficient duration of time to reliably record patients' functional activity in the home and community settings. In addition, the highest test-retest reliability for activities across 7- and 14-day intervals were found for walking-related measures in individuals with PD, indicating these measures have the highest stability compared to the other measures of functional activity.
引用
收藏
页码:327 / 340
页数:14
相关论文
共 50 条
  • [1] Test-retest reliability of a Parkinson's disease monitoring system
    Heldman, D. A.
    Espay, A. J.
    LeWitt, P. A.
    Giuffrida, J. P.
    MOVEMENT DISORDERS, 2013, 28 : S108 - S109
  • [2] Test-Retest Reliability of a Parkinson's Disease Monitoring System
    Heldman, Dustin
    Espay, Alberto
    LeWitt, Peter
    Giuffrida, Joseph
    NEUROLOGY, 2013, 80
  • [3] Test-retest reliability of physical activity questionnaires in Parkinson’s disease
    Samuel Ånfors
    Ann-Sofi Kammerlind
    Maria H. Nilsson
    BMC Neurology, 21
  • [4] Test-retest reliability of physical activity questionnaires in Parkinson's disease
    Anfors, Samuel
    Kammerlind, Ann-Sofi
    Nilsson, Maria H.
    BMC NEUROLOGY, 2021, 21 (01)
  • [5] Test-retest reliability of an epidemiological instrument for Parkinson's disease
    Reider, CR
    Hubble, JP
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2000, 53 (08) : 863 - 865
  • [6] Preliminary Investigation of Test-retest Reliability of a Robotic Assessment for Parkinson's Disease
    Brewer, B. R.
    Pradhan, S.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5863 - 5866
  • [7] Abnormal metabolic network activity in Parkinson's disease: test-retest reproducibility
    Ma, Yilong
    Tang, Chengke
    Spetsieris, Phoebe G.
    Dhawan, Vijay
    Eidelberg, David
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2007, 27 (03): : 597 - 605
  • [8] The Test-Retest Reliability of the Peyronie's Disease Questionnaire
    Coyne, Karin S.
    Currie, Brooke M.
    Thompson, Christine L.
    Smith, Ted M.
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 (02): : 543 - 548
  • [9] Test-retest and inter-rater reliability and construct validity of the 2-minute step test in individuals with Parkinson's disease
    dos Santos, Marina Genari Murad Carolino
    Benazzi, Fabiana Acorse Francischetti
    Uhdre, Andre Luis
    Dibai-Filho, Almir Vieira
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 40 : 2033 - 2041
  • [10] Test-retest reliability of the seated functional rotation test in people with Parkinson's disease: A preliminary study'
    Batavia, M
    Gianutsos, JG
    PERCEPTUAL AND MOTOR SKILLS, 2004, 99 (01) : 259 - 270