Evaluation of Deformable Image Registration Methods for Dose Monitoring in Head and Neck Radiotherapy

被引:54
|
作者
Rigaud, Bastien [1 ,2 ]
Simon, Antoine [1 ,2 ]
Castelli, Joel [1 ,2 ,3 ]
Gobeli, Maxime [3 ]
Arango, Juan-David Ospina [1 ,2 ]
Cazoulat, Guillaume [1 ,2 ]
Henry, Olivier [3 ]
Haigron, Pascal [1 ,2 ]
De Crevoisier, Renaud [1 ,2 ,3 ]
机构
[1] Univ Rennes 1, LTSI, F-35000 Rennes, France
[2] INSERM, U1099, F-35000 Rennes, France
[3] Ctr Eugene Marquis, Dept Radiotherapy, F-35000 Rennes, France
关键词
INTENSITY-MODULATED RADIOTHERAPY; ADAPTIVE RADIATION-THERAPY; STAGE NASOPHARYNGEAL CARCINOMA; NONRIGID REGISTRATION; STRATEGIES; XEROSTOMIA; TISSUE; VOLUME; IMRT;
D O I
10.1155/2015/726268
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44mm (1.30 mm) and 2.54mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85Gy (0.93Gy) and 0.88Gy (0.95Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03Gy (SD=2.27Gy, range: 1.06-8.91Gy).
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Evaluation of deformable image registration methods for dose monitoring in head and neck adaptive radiotherapy
    Rigaud, B.
    Simon, A.
    Castelli, J.
    Gobeli, M.
    Arango, J. D. Ospina
    Cazoulat, G.
    Henry, O.
    Haigron, P.
    De Crevoisier, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S488 - S489
  • [2] Deformable Image Registration Based Delivered Dose Estimation for Head and Neck Radiotherapy
    Kumarasiri, A.
    Liu, C.
    Chetvertkov, M.
    Gordon, J.
    Siddiqui, F.
    Chetty, I.
    Kim, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 191 - 192
  • [3] A QA method for evaluation of deformable image registration in head and neck adaptive radiotherapy
    Cagni, E.
    Botti, A.
    Orlandi, M.
    Galaverni, M.
    Sghedoni, R.
    Iotti, C.
    Spezi, E.
    Iori, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1101 - S1101
  • [4] Quantifying the dose accumulation uncertainty after deformable image registration in head-and-neck radiotherapy
    Lowther, Nicholas J.
    Marsh, Steven H.
    Louwe, Robert J. W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 143 : 117 - 125
  • [5] The Role of Regularization in Deformable Image Registration for Head and Neck Adaptive Radiotherapy
    Ciardo, D.
    Peroni, M.
    Riboldi, M.
    Alterio, D.
    Baroni, G.
    Orecchia, R.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (04) : 323 - 331
  • [6] The impact of robustness of deformable image registration on contour propagation and dose accumulation for head and neck adaptive radiotherapy
    Zhang, Lian
    Wang, Zhi
    Shi, Chengyu
    Long, Tengfei
    Xu, X. George
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 185 - 194
  • [7] Assessment of Dose Accumulation with Different Deformable Image Registration Algorithms for Image-Guided Radiotherapy of Head and Neck Cancer
    Dogan, N.
    Sleeman, W.
    Asher, D.
    Fatyga, M.
    Schutzer, M.
    Song, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Deformable image registration and replanning in head and neck radiotherapy for optimization of parotid sparing
    Meeks, S. L.
    Manon, R. R.
    Kupelian, P. A.
    Lu, W.
    Chen, Q.
    Langen, K. M.
    Ruchala, K. J.
    Haimerl, J.
    Olivera, G. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S99 - S100
  • [9] Uncertainty estimation of dose accumulation with deformable image registration in head and neck region
    Kanehira, T.
    Kranen, S.
    Sonke, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S546 - S547
  • [10] Online Assessment of Dose Changes in Head and Neck Radiotherapy Without Dose Re-Computation Using Deformable Image Registration
    Vickress, J.
    Battista, J.
    Barnett, R.
    Yartsev, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E601 - E601