Comparing Adherence of Continuous and Automatic Positive Airway Pressure (CPAP and APAP) in Obstructive Sleep Apnea (OSA) Children

被引:3
|
作者
Tovichien, Prakarn [1 ]
Kulbun, Aunya [1 ]
Udomittipong, Kanokporn [1 ]
机构
[1] Mahidol Univ, Fac Med Siriraj Hosp, Div Pulmonol, Dept Pediat, Bangkok, Thailand
来源
FRONTIERS IN PEDIATRICS | 2022年 / 10卷
关键词
CPAP; APAP; CPAP adherence; CPAP tolerance; consistency of CPAP use; OSA (obstructive sleep apnoea); children; BARRIERS; THERAPY;
D O I
10.3389/fped.2022.841705
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
ObjectivesThe treatment outcomes of pediatric obstructive sleep apnea (OSA) are affected by positive airway pressure (PAP) therapy adherence, which may be affected by the type of device used. Continuous PAP (CPAP) devices deliver a continuous and fixed air pressure level, whereas automatic PAP (APAP) devices automatically adjust the pressure to meet changing needs during sleep. The adherence, tolerance and consistency of OSA-children's use of CPAP and APAP devices were compared. Study designOne-year, observational cohort study. MethodsTwenty-seven OSA-children were enrolled. Fourteen (52%) used CPAP, and 13 (48%) used APAP. The adherence, tolerance, and consistency of the PAP usage by the two groups were compared. ResultsOverall, 11 of the 27 children (41%) showed good PAP adherence. The CPAP patients averaged 4.9 h of device usage on the days used, for 60% of days, with 6 of 14 (43%) demonstrating good adherence. In comparison, the APAP patients averaged 3.2 h for 55% of days, with 5 of 13 (38%) exhibiting good adherence. The 2 groups showed no differences in their adherence, tolerance, or consistency of device usage (P values, 0.816, 0.609, and 0.720, respectively). Although the adherence of both groups improved in the second 6 months, it was without statistical significance (P values, 0.400 and 0.724). Age, sex, baseline apnea-hypopnea index, comorbidities, prescribed period, device type, mask type, and caregiver education-level were not risk factors for poor PAP adherence. ConclusionsNo differences in the adherence, tolerance, or consistency of the children's use of CPAP and APAP were revealed in this small inhomogeneous cohort study with limited resources.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Positional obstructive sleep apnea (OSA) and automatic positive airway pressure (APAP) therapy
    Dias, Ana Rita
    Martinho, Cristina
    Silva, Ana Marta
    Leitao, Catarina
    Almeida, Liliana
    Escaleira, Marta
    Cardoso, Vanessa
    Basto, Rita Pinto
    Pinto, Paula
    Barbara, Cristina
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [2] Factors determining adherence to continuous positive airway pressure (CPAP) therapy in veterans with obstructive sleep apnea (OSA)
    Budhiraja, R.
    Zeater, M.
    Parthasarathy, S.
    Quan, S.
    [J]. SLEEP, 2007, 30 : A166 - A166
  • [3] Continuous Positive Airway Pressure (cpap) Adherence Following Bariatric Surgery In Patients With Obstructive Sleep Apnea (osa)
    Vipul, K.
    Raju, S.
    Raju, N.
    Jaffe, F.
    Chatila, W.
    Shariff, T.
    Ciccolella, D. E.
    Krachman, S.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [4] Machine learning-based prediction of adherence to continuous positive airway pressure (CPAP) in obstructive sleep apnea (OSA)
    Scioscia, Giulia
    Tondo, Pasquale
    Barbaro, Maria Pia Foschino
    Sabato, Roberto
    Gallo, Crescenzio
    Maci, Federica
    Lacedonia, Donato
    [J]. INFORMATICS FOR HEALTH & SOCIAL CARE, 2022, 47 (03): : 274 - 282
  • [5] High adherence to continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) in Belgium: a narrative review
    Buyse, Bertien
    Bruyneel, Marie
    Verbraecken, Johan
    Testelmans, Dries
    [J]. ACTA CLINICA BELGICA, 2022, 77 (03) : 710 - 720
  • [6] Factors determining continuous positive airway pressure (CPAP) compliance in obstructive sleep apnea (OSA)
    Riachy, Moussa
    Najem, Samer
    Iskandar, Mirella
    Choucair, Jad
    Ibrahim, Ihab
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [7] Determinants of the effective level of continuous positive airway pressure (CPAP) in obstructive sleep apnea (OSA)
    Ioachimescu, OC
    Lamont, J
    Bae, C
    Foldvary-Schaefer, N
    Golish, J
    [J]. CHEST, 2005, 128 (04) : 233S - 233S
  • [8] Nasal Breathing and Continuous Positive Airway Pressure (CPAP) in Patients with Obstructive Sleep Apnea (OSA)
    Jan H. Hollandt
    Malte Mahlerwein
    [J]. Sleep and Breathing, 2003, 7 (2) : 87 - 93
  • [9] Long term compliance with Continuous Positive Airway Pressure (CPAP) for Obstructive Sleep Apnea (OSA)
    Gulati, A.
    Morrish, E.
    Pilsworth, S.
    Quinnell, T.
    Shneerson, J. M.
    Smith, I. E.
    [J]. JOURNAL OF SLEEP RESEARCH, 2008, 17 : 44 - 44
  • [10] The Use of Automatic Continuous Positive Airway Pressure (APAP) Therapy in Severe Obstructive Sleep Apnoea (OSA)
    Sivaramakrishnan, H.
    Chung, Y.
    Cossa, G.
    Laks, L.
    Brillante, R.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197