Analysis of different containment models for IRIS small break LOCA, using GOTHIC and RELAP5 codes

被引:46
|
作者
Papini, Davide [1 ]
Grgic, Davor [2 ]
Cammi, Antonio [1 ]
Ricotti, Marco E. [1 ]
机构
[1] Politecn Milan, Dept Energy, CeSNEF Nucl Engn Div, I-20156 Milan, Italy
[2] Univ Zagreb, Dept Power Syst, FER, Zagreb 10000, Croatia
关键词
CONDENSATION HEAT-TRANSFER; NONCONDENSABLE GASES; AP600; CONTAINMENT; VERTICAL TUBE; REACTOR; STEAM;
D O I
10.1016/j.nucengdes.2010.06.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Advanced nuclear water reactors rely on containment behaviour in realization of some of their passive safety functions. Steam condensation on containment walls, where non-condensable gas effects are significant, is an important feature of the new passive containment concepts, like the AP600/1000 ones. In this work the international reactor innovative and secure (IRIS) was taken as reference, and the relevant condensation phenomena involved within its containment were investigated with different computational tools. In particular, IRIS containment response to a small break LOCA (SBLOCA) was calculated with GOTHIC and RELAP5 codes. A simplified model of IRIS containment drywell was implemented with RELAP5 according to a sliced approach, based on the two-pipe-with-junction concept, while it was addressed with GOTHIC using several modelling options, regarding both heat transfer correlations and volume and thermal structure nodalization. The influence on containment behaviour prediction was investigated in terms of drywell temperature and pressure response, heat transfer coefficient (HTC) and steam volume fraction distribution, and internal recirculating mass flow rate. The objective of the paper is to preliminarily compare the capability of the two codes in modelling of the same postulated accident, thus to check the results obtained with RELAP5, when applied in a situation not covered by its validation matrix (comprising SBLOCA and to some extent LBLOCA transients, but not explicitly the modelling of large dry containment volumes). The option to include or not droplets in fluid mass flow discharged to the containment was the most influencing parameter for GOTHIC simulations. Despite some drawbacks, due, e.g. to a marked overestimation of internal natural recirculation, RELAP5 confirmed its capability to satisfactorily model the basic processes in IRIS containment following SBLOCA. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1152 / 1164
页数:13
相关论文
共 50 条
  • [1] THE EFFECT OF IRWST SIMULATION METHOD ON THE ANALYSIS OF SMALL BREAK LOCA USING RELAP5
    Xu, Caihong
    Shi, Guobao
    Cao, Kemei
    Cai, Xiaoyu
    Qi, Zhanfe
    [J]. PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [2] ANALYSIS OF SMALL-BREAK LOCA AT ACME TEST FACILITY USING RELAP5/MOD3
    Xu Caihong
    Shi Guobao
    Fan Pu
    [J]. PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 3, 2016,
  • [3] Analysis of the IAEA SPE-4 small-break LOCA experiment with RELAP5, TRACE and APROS system codes
    Varju, Tamas
    Aranyosy, Adam
    Orosz, Robert
    Holl, Viktor
    Hajas, Tamas
    Aszodi, Attila
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2021, 377
  • [4] Analysis of depressurization ability for IRIS containment during SBLOCAs using RELAP5 and CONTEMPT
    Huang, Mengqi
    Peng, Changhong
    Liu, Zihan
    [J]. ANNALS OF NUCLEAR ENERGY, 2023, 180
  • [5] RELAP5 ASSESSMENT WITH LOBI SMALL-BREAK LOCA TEST-RESULTS
    STADTKE, H
    WORTH, B
    KOLAR, W
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1987, 102 (02) : 183 - 190
  • [6] Sensitivity analysis of the IAEA SPE-2 small-break LOCA experiment with RELAP5, TRACE and APROS system codes
    Varju, Tamas
    Orosz, Robert
    Aranyosy, Adam
    Holl, Viktor
    Hajas, Tamas
    Aszodi, Attila
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2022, 388
  • [7] Coupling Gothic and RELAP5 for Passive Containment Cooling Modeling
    Kang, J. C.
    Jeong, J. S.
    Lee, D. H.
    George, T. L.
    Lane, J. W.
    Thomasson, S. G.
    [J]. NUCLEAR TECHNOLOGY, 2021, 207 (12) : 1851 - 1864
  • [8] Small break LOCA analysis without emergency core cooling systems using the RELAP5/SCDAP code in VVER-1000 reactor
    Salehi, Mohsen
    Jahanfarnia, Gholamreza
    [J]. ANNALS OF NUCLEAR ENERGY, 2016, 87 : 299 - 307
  • [9] The Behavior of ANGRA 2 Nuclear Power Plant Core for a Small Break LOCA Simulated with RELAP5 Code
    Sabundjian, Gaiane
    Andrade, Delvonei A.
    Belchior, Antonio, Jr.
    Rocha, Marcelo da Silva
    Conti, Thadeu N.
    Torres, Walmir M.
    Macedo, Luiz A.
    Umbehaun, Pedro E.
    Mesquita, Roberto N.
    Masotti, Paulo H. F.
    de Souza Lima, Ana Cecilia
    [J]. XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 : 151 - 154
  • [10] Best Estimate Plus Uncertainty analysis of a large break LOCA on Generation III reactor with RELAP5
    Yang, Jun
    Yang, Ye
    Deng, Chengcheng
    Ishii, Mamaru
    [J]. ANNALS OF NUCLEAR ENERGY, 2019, 127 : 326 - 340