Assessment of left atrial pressure and volume changes during atrial systole with transesophageal pulsed Doppler echocardiography of transmitral and pulmonary venous flow velocities

被引:0
|
作者
Oki, T
Kageji, Y
Fukuda, N
Iuchi, A
Tabata, T
Manabe, K
Yamada, H
Fukuda, K
Ito, S
机构
来源
JAPANESE HEART JOURNAL | 1996年 / 37卷 / 03期
关键词
transmitral flow velocity; pulmonary venous flow velocity; atrial systolic wave; LA hemodynamics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine whether transmitral and pulmonary venous flow velocity patterns can be used to evaluate left atrial pressure and volume changes during atrial systole, we performed transesophageal pulsed Doppler echocardiography and right heart catheterization in 85 patients (20 with hypertrophic cardiomyopathy, 20 with dilated cardiomyopathy, 30 with prior myocardial infarction, and 15 with mitral regurgitation), and 35 normal subjects. Pulsed Doppler variables from transmitral and pulmonary venous flow velocities during atrial systole were compared with mean pulmonary capillary wedge pressure (mean PCWP), pressure rise during atrial systole (PCWP-A), and left atrial volume change during atrial systole (Delta LAV). The mean PCWP correlated sig significantly with the peak atrial systolic transmitral flow (r = -0.38, p < 0.05) and pulmonary venous flow (r = 0.40, p < 0.05) velocities in all patients. The PCWP-A correlated significantly with the peak atrial systolic transmitral flow (r = -0.39, p < 0.05) and pulmonary venous flow (r = 0.68, P < 0.0001) velocities in all patients. There was a particularly close correlation between the PCWP-A and the peak atrial systolic pulmonary venous flow velocities. The sum of the time-velocity integral of the atrial systolic transmitral and pulmonary venous flow velocities (TAI) correlated closely with the Delta LAV (r = 0.70, P < 0.0001) in all patients. Thus, the peak atrial systolic pulmonary venous flow velocity correlated well with left atrial pressure changes during atrial systole. Furthermore, the sum of the time-velocity integral of the atrial systolic transmitral and pulmonary venous flow velocities correlated well with left atrial volume changes during atrial systole. Therefore, transesophageal echocardiographic measurements of atrial systolic transmitral and pulmonary venous flow velocities are reasonable indicators of left atrial pressure and volume changes during atrial systole.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 50 条
  • [1] ESTIMATION OF MEAN LEFT ATRIAL PRESSURE FROM TRANSESOPHAGEAL PULSED DOPPLER ECHOCARDIOGRAPHY OF PULMONARY VENOUS FLOW
    KUECHERER, HF
    MUHIUDEEN, IA
    KUSUMOTO, FM
    LEE, E
    MOULINIER, LE
    CAHALAN, MK
    SCHILLER, NB
    CIRCULATION, 1990, 82 (04) : 1127 - 1139
  • [2] Assessment of abnormal left atrial relaxation by transesophageal pulsed Doppler echocardiography of pulmonary venous flow velocity
    Oki, T
    Tabata, T
    Yamada, H
    Fukuda, K
    Abe, M
    Onose, Y
    Wakatsuki, T
    Iuchi, A
    Ito, S
    CLINICAL CARDIOLOGY, 1998, 21 (10) : 753 - 758
  • [3] Transesophageal pulsed Doppler echocardiographic, evaluation of left atrial systolic performance in hypertrophic cardiomyopathy: Combined analysis of transmitral and pulmonary venous flow velocities
    Oki, T
    Iuchi, A
    Tabata, T
    Yamada, H
    Manabe, K
    Kageji, Y
    Abe, M
    Fukuda, N
    Ito, S
    CLINICAL CARDIOLOGY, 1997, 20 (01) : 47 - 54
  • [4] Influence of left atrial function on Doppler transmitral and pulmonary venous flow patterns in dilated and hypertrophic cardiomyopathy: Evaluation of left atrial appendage function by transesophageal echocardiography
    Ito, T
    Suwa, M
    Hirota, Y
    Otake, Y
    Moriguchi, A
    Kawamura, K
    AMERICAN HEART JOURNAL, 1996, 131 (01) : 122 - 130
  • [5] PULMONARY VENOUS FLOW PATTERNS ASSESSED BY TRANSESOPHAGEAL PULSED DOPPLER-ECHOCARDIOGRAPHY IN LEFT ATRIAL-MYXOMA
    KISANUKI, A
    SHIBATA, K
    OTSUJI, Y
    KUROIWA, R
    MURAYAMA, T
    MATSUSHITA, R
    NAKAO, S
    NOMOTO, K
    TAIRA, A
    TANAKA, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (14): : 1089 - 1093
  • [6] Left atrial systolic performance in the presence of elevated left ventricular end-diastolic pressure: Evaluation by transesophageal pulsed Doppler echocardiography of left ventricular inflow and pulmonary venous flow velocities
    Oki, T
    Fukuda, N
    Iuchi, A
    Tabata, T
    Tanimoto, M
    Manabe, K
    Kageji, Y
    Sasaki, M
    Yamada, H
    Ito, S
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (01): : 23 - 32
  • [7] PULMONARY VENOUS FLOW PATTERN STUDIED BY TRANSESOPHAGEAL PULSED DOPPLER-ECHOCARDIOGRAPHY IN MITRAL-STENOSIS IN SINUS RHYTHM - EFFECT OF ATRIAL SYSTOLE
    STOJNIC, BB
    RADJEN, GS
    PERISIC, NJ
    PAVLOVIC, PB
    STOSIC, JJ
    PRCOVIC, M
    EUROPEAN HEART JOURNAL, 1993, 14 (12) : 1597 - 1601
  • [8] PULMONARY VENOUS FLOW ASSESSMENT OF MITRAL REGURGITATION - A SIMULTANEOUS LEFT ATRIAL PRESSURE AND TRANSESOPHAGEAL ECHO DOPPLER STUDY
    KLEIN, AL
    STEWART, WJ
    LITOWITZ, H
    PEARCE, GL
    LYTLE, BW
    COSGROVE, DM
    SALCEDO, EE
    CIRCULATION, 1990, 82 (04) : 552 - 552
  • [9] SIMULTANEOUS MEASUREMENT OF PULMONARY VENOUS FLOW BY INTRAVASCULAR CATHETER DOPPLER VELOCIMETRY AND TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHY - RELATION TO LEFT ATRIAL PRESSURE AND LEFT ATRIAL AND LEFT-VENTRICULAR FUNCTION
    HOFMANN, T
    KECK, A
    VANINGEN, G
    SIMIC, O
    OSTERMEYER, J
    MEINERTZ, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (01) : 239 - 249
  • [10] Effect of atrial fibrillation on pulmonary venous flow patterns assessed by Doppler transesophageal echocardiography
    Chao, TS
    Tsai, LM
    Tsai, WC
    Li, YH
    Lin, LJ
    Chen, JH
    CHEST, 2000, 117 (06) : 1546 - 1550