Application of contrast-enhanced ultrasound in the diagnosis of small breast lesions

被引:32
|
作者
Du, Yan-Ran [1 ]
Wu, Yang [1 ]
Chen, Man [2 ]
Gu, Xin-Gang [1 ]
机构
[1] Shanghai Putuo Dist Cent Hosp, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Tong Ren Hosp, Sch Med, Dept Diagnost Ultrasound, 1111 Xian Xia Rd, Shanghai 200336, Peoples R China
基金
中国国家自然科学基金;
关键词
Small breast lesions; contrast-enhanced ultrasound; peak intensity; breast imaging-reporting and data system; SHEAR-WAVE ELASTOGRAPHY; DATA SYSTEM; CANCER; BENIGN; COMBINATION; CARCINOMA; FEATURES; TUMORS;
D O I
10.3233/CH-170368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Breast cancer is the most common cancer in women worldwide. The purpose of the study was to observe the features of contrast-enhanced ultrasound (CEUS) and the combination with Breast Imaging-Reporting and Data System (BI-RADS) of conventional ultrasound for assessing small breast lesions. OBJECTIVES: The study was to explore the small breast lesions' features of contrast-enhanced ultrasound (CEUS) and the combination with Breast Imaging-Reporting and Data System (BI-RADS) of conventional ultrasound, in order to improve the diagnostic accuracy of early breast cancer. METHODS: 105 lesions were subject to conventional US (ultrasound) and CEUS before operations or biopsies. Among 105 breast lesions, six patient diagnoses were established by thick core-needle biopsy, while the rest were all confirmed by surgery and pathology. RESULTS: Significant differences were found between benign and malignant lesions in qualitative and quantitative indexes (peak) of CEUS (P < 0.05). The qualitative features of malignant small breast lesions were as follows: (1) enhanced intensity within the lesion was not uniform (61/61,100%); (2) the speed of wash-in was earlier than the surrounding tissue (58/61, 95.1%); (3) lesion interior and the surrounding tissues had contrast vessel performance (61/61,100%). Peak of malignant lesions (35.77 +/- 11.45) was higher than that of benign lesions (31.96 +/- 10.76) (P < 0.05). The diagnostic performance of BI-RADS-US plus qualitative indexes (method one) in terms of area under receiver operating characteristic curve (AUROC) were the highest (i.e., AUROC = 0.817), in comparison with other combined diagnostic methods. The associated sensitivity, specificity and accuracy were 78.69%, 84.09% and 80.95%, respectively. With method one, however, was similar with USBI-RADS in specificity, 11 malignant breast lesions were regarded as a higher classification of BI-RADS and classified into malignant group, which were identified as benign on US-BI-RADS originally. CONCLUSIONS: CEUS was useful to differentiate benign from malignant small breast lesions, and the combination of CEUS and BI-RADS-US can improve the early diagnosis of breast cancers.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [1] Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions-A comparison of conventional ultrasound and contrast-enhanced CT
    Fan, Zhihui
    Li, Ying
    Yan, Kun
    Wu, Wei
    Yin, Shanshan
    Yang, Wei
    Xing, Baocai
    Li, Xiaoting
    Zhang, Xiaopeng
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : 1385 - 1390
  • [2] Clinical value and application of contrast-enhanced ultrasound in the differential diagnosis of malignant and benign breast lesions
    Zhang, Yan
    Zhang, Bmeiwu
    Fan, Xiaoxiang
    Mao, Dafeng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (03) : 2063 - 2069
  • [3] Current status and future perspectives of contrast-enhanced ultrasound diagnosis of breast lesions
    Ito, Toshikazu
    Manabe, Hironobu
    Kubota, Michiyo
    Komoike, Yoshifumi
    JOURNAL OF MEDICAL ULTRASONICS, 2024, : 611 - 625
  • [4] Contrast-Enhanced Ultrasound in the Diagnosis of Solid Renal Lesions
    Zbroja, Monika
    Kuczynska, Maryla
    Drelich, Katarzyna
    Mikos, Eryk
    Zarajczyk, Agata
    Cheda, Mateusz
    Dabrowska, Izabela
    Drelich-Zbroja, Anna
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [5] Application value of contrast-enhanced ultrasound in the diagnosis of peripheral pulmonary focal lesions
    Bai, Zina
    Liu, Tong
    Liu, Wei
    Li, Zhensheng
    Zheng, Hao
    Li, Xingbin
    MEDICINE, 2022, 101 (29) : E29605
  • [6] Value of an expanded range of lesions on contrast-enhanced ultrasound for the diagnosis of hypervascular breast masses
    Jia, Chao
    Niu, Qinghua
    Liu, Long
    Li, Gang
    Jin, Lifang
    Du, Lianfang
    Shi, Qiusheng
    Li, Fan
    GLAND SURGERY, 2023, 12 (06) : 824 - 833
  • [7] Application of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Subpleural Pulmonary Lesions
    Shen, MengJun
    Bi, Ke
    Cong, Yang
    Chen, HongWei
    Zhang, Yi
    Zhu, HuiMing
    Wang, Yin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1147 - 1157
  • [8] ROLE OF CONTRAST-ENHANCED ULTRASOUND IN DIAGNOSIS OF RAISED GALLBLADDER LESIONS
    Terracciano, F.
    Varvara, D.
    Oliva, G.
    Scalisi, G.
    Scimeca, D.
    Biscaglia, G.
    Bossa, F.
    Andriulli, A.
    DIGESTIVE AND LIVER DISEASE, 2015, 47 : E200 - E201
  • [10] Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions
    Gomez Molins, Ines
    Fernandez Font, Juan Manuel
    Carrero Alvaro, Juan
    Lledo Navarro, Jose Luis
    Fernandez Gil, Marta
    Fernandez Rodriguez, Conrado M.
    WORLD JOURNAL OF RADIOLOGY, 2010, 2 (12): : 455 - 462