A method for determination of the absorption and scattering properties interstitially in turbid media

被引:87
|
作者
Dimofte, A [1 ]
Finlay, JC [1 ]
Zhu, TC [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 10期
关键词
D O I
10.1088/0031-9155/50/10/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a method to quickly determine tissue optical properties (absorption coefficient mu(a) and transport scattering coefficient mu(s)') by measuring the ratio of light fluence rate to source power along a linear channel at a fixed distance (5 mm) from an isotropic point source. Diffuse light is collected by an isotropic detector whose position is determined by a computer-controlled step motor, with a positioning accuracy of better than 0.1 mm. The system automatically records and plots the light fluence rate per unit source power as a function of position. The result is fitted with a diffusion equation to determine it, and mu(s)'. We use an integrating sphere to calibrate each source-detector pair, thus reducing uncertainty of individual calibrations. To test the ability of this algorithm to accurately recover the optical properties of the tissue, we made measurements in tissue simulating phantoms consisting of Liposyn at concentrations of 0.23, 0.53 and 1.14% (mu(s)' = 1.7-9.1 cm(-1)) in the presence of Higgins black India ink at concentrations of 0.002, 0.012 and 0.023% (mu(a) = 0.1-1 cm(-1)). For comparison, the optical properties of each phantom are determined independently using broad-beam illumination. We find that mu(a) and mu(s)' can be determined by this method with a standard (maximum) deviation of 8% (15%) and 18% (32%) for A. and mu(s)' respectively. The current method S is effective for samples whose optical properties satisfy the requirement of the diffusion approximation. The error caused by the air cavity introduced by the catheter is small, except when mu(a) is large (mu(a) > 1 cm(-1)). We presented in vivo data measured in human prostate using this method.
引用
收藏
页码:2291 / 2311
页数:21
相关论文
共 50 条
  • [1] ON SEPARATE DETERMINATION OF COEFFICIENTS OF ABSORPTION AND SCATTERING OF TURBID MEDIA
    LEVIN, IM
    IVANOV, AP
    OPTICS AND SPECTROSCOPY-USSR, 1965, 18 (05): : 520 - &
  • [2] A simple method for determination of optical properties of turbid media
    Xu, KX
    Han, YH
    Ni, Y
    Hu, YZ
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 186 - 194
  • [3] Simultaneous determination of the scattering and absorption coefficients of turbid media based on Mueller matrix
    Ren, Yuhu
    Kong, Delai
    Tan, Wenjiang
    Wang, Jing
    Chen, Tao
    Zhang, Qingyue
    Zhang, Haikun
    Xia, Wei
    Journal of Modern Optics, 2024, 71 (10-12) : 354 - 363
  • [5] Fully automated spatially resolved reflectance spectrometer for the determination of the absorption and scattering in turbid media
    Foschum, F.
    Jaeger, M.
    Kienle, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (10):
  • [6] Determination of optical scattering properties in turbid media using Mueller matrix imaging
    Cameron, Brent D.
    Li, Yanfang
    Nezhuvingal, Ajaina
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (05)
  • [7] Imaging of highly turbid media by the absorption method
    Contini, D
    Liszka, H
    Sassaroli, A
    Zaccanti, G
    APPLIED OPTICS, 1996, 35 (13): : 2315 - 2324
  • [8] Theory of light propagation incorporating scattering and absorption in turbid media
    Yang, L
    Miklavcic, SJ
    OPTICS LETTERS, 2005, 30 (07) : 792 - 794
  • [9] A Photoacoustic Method for Optical Scattering Measurements in Turbid Media
    Zemp, Roger J.
    Ranasinghesagara, Janaka
    Jiang, Yan
    Chen, Xuhui
    Mathewson, Kory
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2009, 2009, 7177
  • [10] DETERMINATION OF SINGLE-SCATTERING ALBEDO IN HIGHLY TURBID MEDIA
    GORYACHEV, BV
    LARIONOV, VV
    MOGILNITSKII, SB
    SAVELEV, BA
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1988, 55 (10): : 636 - 638