An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry

被引:40
|
作者
Flores, Erick [1 ]
Pizarro, Jaime [1 ]
Godoy, Fernando [1 ]
Segura, Rodrigo [1 ]
Gomez, Alejandra [1 ]
Agurto, Nicolas [1 ]
Sepulveda, Pamela [2 ]
机构
[1] Univ Santiago Chile USACH, Dept Quim Mat, Fac Quim & Biol, Santiago 3363, Chile
[2] Univ Santiago Chile USACH, Fac Quim & Biol, CEDENNA, Santiago 3363, Chile
关键词
Macrocylic fragment; Ferrocenyl imine; Electrochemical sensor; Square wave anodic stripping voltammetry; Copper; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; COPPER DETERMINATION; WATER SAMPLES; CADMIUM; LEAD; COMPLEXES; ZINC; CONTAMINATION; CHEMOSENSORS;
D O I
10.1016/j.snb.2017.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor based on a glassy carbon electrode modified with ferrocenyl imine [(eta(5)-C5H4CH=N-4'-benzo-15-crown-5)Fe(eta(5)-C5H5)] (FcIB15C5) has been developed for the determination of Cu(II) using square wave anodic stripping voltammetry (SWASV). The metalloligand was synthesized from ferrocene-carboxaldehyde and 4'-aminobenzo-15-crown-5. The metalloligand FcIB15C5 was characterized by FT-IR, H-1 - C-13 NMR spectroscopies and mass spectrometry and was obtained as a single isolated isomer (E-configuration). The optimum conditions for the prepared electrode were as follows: BrittonRobinson buffer with pH = 6.0, FcIB15C5 concentration = 0.3 mM, accumulation potential (E-acc) = -0.8 V and accumulation time (t(acc)) = 90 s. A linear range was observed from 10 to 70 mu g L-1 with a limit of detection (LOD) of 0.11 mu g L-1. The proposed procedure was validated with TMDA-64.2 and CRM-TMDW certified reference materials, and it showed good accuracy and precision. The methodology was applied to a mining effluent and urine samples with satisfactory results. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [21] Simultaneous quantification of Hg(II) and Pb(II) by square wave anodic stripping voltammetry using Bi/graphite electrode
    Clavijo, Juan A. M.
    Zea, Hugo R. R.
    HELIYON, 2024, 10 (14)
  • [22] Analysis of Cu in Mezcal Commercial Samples using Square Wave Anodic Stripping Voltammetry
    Salinas, Gerardo
    Ibanez, Jorge G.
    Vasquez-Medrano, Ruben
    Frontana-Uribe, Bernardo A.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2018, 9 (04) : 276 - 281
  • [23] Simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry at a gold nanoparticle-graphene-cysteine composite modified bismuth film electrode
    Zhu, Lian
    Xu, Lili
    Huang, Baozhen
    Jia, Ningming
    Tan, Liang
    Yao, Shouzhuo
    ELECTROCHIMICA ACTA, 2014, 115 : 471 - 477
  • [24] Simultaneous determination of Cd(II), Pb(II), Cu(II) and Bi(III)by square wave anodic stripping voltammetry and multivariate calibration
    Fan, Qingjie
    Du, Guorong
    Tu, Jiarun
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2013, 46 (02): : 145 - 149
  • [25] Electrodeposition of zinc hydroxide on carbon graphite electrode for electrochemical determination of trace copper in water samples using square wave anodic stripping voltammetry
    Berrabah, Salah Eddine
    Benchettara, Abdelkader
    Smaili, Fatiha
    Tabti, Sabrina
    Benchettara, Abdelhakim
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 278
  • [26] Determination of trace lead by square-wave anodic stripping voltammetry
    Wang, Mingliang
    Li, Minjing
    Yejin Fenxi/Metallurgical Analysis, 2000, 20 (01): : 42 - 44
  • [27] Determination of copper ion by square wave anodic stripping voltammetry at antimony trioxide-modified carbon nanotube paste electrode
    Mahsa Majidian
    Jahan Bakhsh Raoof
    Sayed Reza Hosseini
    Reza Ojani
    Journal of the Iranian Chemical Society, 2017, 14 : 1263 - 1270
  • [28] Determination of copper ion by square wave anodic stripping voltammetry at antimony trioxide-modified carbon nanotube paste electrode
    Majidian, Mahsa
    Raoof, Jahan Bakhsh
    Hosseini, Sayed Reza
    Ojani, Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1263 - 1270
  • [29] Fabrication of carbon nanotube and synthesized Octadentate ligand modified electrode for determination of Hg (II) in Sea water and Lake water using square wave anodic stripping voltammetry
    Gayathri, Jayagopi
    Selvan, Kumar Sangeetha
    Narayanan, Sangilimuthu Sriman
    SENSING AND BIO-SENSING RESEARCH, 2018, 19 : 1 - 6
  • [30] Determination of Copper in Water by Anodic Stripping Voltammetry Using Cu-DPABA-NA/GCE Modified Electrode
    Stankovic, Dalibor
    Roglic, Goran
    Mutic, Jelena
    Andjelkovic, Ivan
    Markovic, Marijana
    Manojlovic, Dragan