Development of an analytical method for the determination of β2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5--luminol chemiluminescence detection

被引:51
|
作者
Zhang, Yantu
Zhang, Zhujun [1 ]
Sun, Yonghua
Wei, Yue
机构
[1] Shaanxi Normal Univ, Coll Chem & Mat Sci, Xian 710062, Peoples R China
[2] Yanan Univ, Coll Chem & Chem Engn, Yanan 716000, Peoples R China
关键词
beta(2)-agonists; chemiluminescence detector; on-line electrogenerated [Cu(HIO6)(2)](5-); high-performance; liquid chromatography; pig liver;
D O I
10.1021/jf070144y
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A novel method was developed for the simultaneous determination of beta(2)-agonist residues such as terbutaline, salbutamol, and clenbuterol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection. The procedure was based on the enhancement effect of beta(2)-agonists on the CL reaction between luminol and the complex of trivalent copper and periodate ([Cu(HIO6)(2)](5-)), which was on-line electrogenerated by constant current electrolysis. The HPLC separation used a Nucleosil RP-C-18 column (250 mm x 4.6 mm i.d., 5 mu m; pore size, 100 A) with a mobile phase consisting of 90% acetonitrile and 10% aqueous ammonium acetate (20 mmol L-1, pH 4.0) at a flow rate of 1.0 mL min(-1). The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Liver samples were hydrolyzed with beta-glucuronidase followed by a solid-phase extraction procedure using Waters OasisMCX cartridges. Under optimum conditions, the limits of detection at a signal-to-noise ratio of 3 ranged from 0.007 to 0.01 ng g(-1) and the limits of quantification at a signal-to-noise ratio of 10 ranged from 0.023 to 0.033 ng g(-1) for three beta(2)-agonists. The relative standard deviations (RSDs) of intra- and interday precision were below 4.5%. The average recoveries for beta(2)-agonists (spiked at the levels of 0.05-5.0 ng g(-1)) in pig liver ranged from 84 to 110%, and the RSDs of the quantitative results were from 1.6 to 7.2%. The proposed method was successfully applied to the determination of beta(2)-agonist residues in pig liver samples.
引用
收藏
页码:4949 / 4956
页数:8
相关论文
共 35 条
  • [1] Detection of glucocorticoid residues in pig liver by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5--luminol chemiluminescence detection
    Zhang, Yantu
    Zhang, Zhujun
    Song, Yonghua
    Wei, Yue
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 260 - 268
  • [2] Determination of sugars by LC with on-line electrogenerated Cu(HIO6)2]5--luminol chemiluminescence detection
    Sun, Yonghua
    Zhang, Zhujun
    Zhang, Yantu
    Wei, Yue
    CHROMATOGRAPHIA, 2008, 67 (9-10) : 825 - 827
  • [3] Determination of Sugars by LC with On-Line Electrogenerated Cu(HIO6)2]5−–Luminol Chemiluminescence Detection
    Yonghua Sun
    Zhujun Zhang
    Yantu Zhang
    Yue Wei
    Chromatographia, 2008, 67 : 825 - 827
  • [4] The Determination Method of Total Polyphenol in Tea and Substitute Tea Based on [Ag(HIO6)2]5--Luminol Chemiluminescence System
    Su, Fang
    Yang, Hui
    Ma, Tian
    Chen, Meifang
    Liu, Shipeng
    Ma, Li
    JOURNAL OF AOAC INTERNATIONAL, 2022, 106 (01) : 205 - 211
  • [5] Flow-injection chemiluminescence determination of chlortetracycline using on-line electrogenerated [Cu(HIO6)2]5- as the oxidant
    Li, BX
    Zhang, ZJ
    Liu, W
    TALANTA, 2001, 55 (06) : 1097 - 1102
  • [6] Sensitive determination of norepinephrine, epinephrine, dopamine and 5-hydroxytryptamine by coupling HPLC with [Ag(HIO6)2]5--luminol chemiluminescence detection
    Wu, Dong
    Xie, He
    Lu, Haifeng
    Li, Wei
    Zhang, Qunlin
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (09) : 1458 - 1466
  • [7] Development and optimization of an analytical method for the determination of Sudan dyes in hot chilli pepper by high-performance liquid chromatography with on-line electrogenerated BrO--luminol chemiluminescence detection
    Zhang, Yantu
    Zhang, Zhujun
    Sun, Yonghua
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1129 (01) : 34 - 40
  • [8] Development of chemiluminescence method for determination of 10-hydroxycamptothecin based on luminol-[Ag(HIO6)2]5- reaction in alkaline solution
    Sun, Hanwen
    Chen, Peiyun
    Shi, Shasha
    Li, Liqing
    LUMINESCENCE, 2011, 26 (05) : 356 - 362
  • [9] Rapid method for the determination of ampicillin residues in animal muscle tissues by high-performance liquid chromatography with fluorescence detection
    Luo, WH
    Ang, CYW
    Thompson, HC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 694 (02): : 401 - 407
  • [10] Sensitive determination of domoic acid using high-performance liquid chromatography with electrogenerated tris(2,2′-bipyridine)ruthenium(III) chemiluminescence detection
    Kodamatani, H
    Saito, K
    Niina, N
    Yamazaki, S
    Muromatsu, A
    Sakurada, I
    ANALYTICAL SCIENCES, 2004, 20 (07) : 1065 - 1068