Scatter-to-primary based scatter fractions for transmission-dependent convolution subtraction of SPECT images

被引:6
|
作者
Larsson, A [1 ]
Johansson, L [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, SE-90187 Umea, Sweden
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 22期
关键词
D O I
10.1088/0031-9155/48/22/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In single photon emission computed tomography (SPECT), transmission-dependent convolution subtraction has been shown to be useful when correcting for scattered events. The method is based on convolution subtraction, but includes a matrix of scatter fractions instead of a global scatter fraction. The method can be extended to iteratively improve the scatter estimate, but in this note we show that this requires a modification of the theory to use scatter-to-total scatter fractions for the first iteration only and scatter-to-primary fractions thereafter. To demonstrate this, scatter correction is performed on a Monte Carlo simulated image of a point source of activity in water. The modification of the theory is compared to corrections where the scatter fractions are based on the scatter-to-total ratio, using one and ten iterations. The resulting ratios of subtracted to original counts are compared to the true scatter-to-total ratio of the simulation and the most accurate result is found for our modification of the theory.
引用
收藏
页码:N323 / N328
页数:6
相关论文
共 21 条
  • [1] A TRANSMISSION-DEPENDENT METHOD FOR SCATTER CORRECTION IN SPECT
    MEIKLE, SR
    HUTTON, BF
    BAILEY, DL
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (02) : 360 - 367
  • [2] SPECT collimator dependency of scatter and validation of transmission-dependent scatter compensation methodologies
    Kim, KM
    Watabe, H
    Shidahara, M
    Ishida, Y
    Iida, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 689 - 696
  • [3] Three-dimensional SPECT reconstruction with transmission-dependent scatter correction
    Antti Sohlberg
    Hiroshi Watabe
    Hidehiro Iida
    Annals of Nuclear Medicine, 2008, 22 : 549 - 556
  • [4] Three-dimensional SPECT reconstruction with transmission-dependent scatter correction
    Sohlberg, Antti
    Watabe, Hiroshi
    Iida, Hidehiro
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (07) : 549 - 556
  • [5] Transmission-dependent convolution subtraction of 99mTc-HMPAO rCBF SPECT -: A Monte Carlo study
    Larsson, A
    Johansson, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 231 - 237
  • [6] Comparison of transmission-dependent and energy-window based scatter correction methods for quantitative SPECT imaging for 225Ac
    Liubchenko, G.
    Rumiantcev, M.
    Resch, S.
    Zacherl, M.
    Gildehaus, F.
    Bartenstein, P.
    Ziegler, S.
    Boening, G.
    Delker, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S374 - S374
  • [7] SEGMENTATION OF THE BODY, LUNGS, AND PATIENT TABLE FROM SCATTER AND PRIMARY WINDOW IMAGES IN SPECT
    PAN, TS
    KING, MA
    PENNEY, BC
    RAJEEVAN, N
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P195 - P195
  • [8] Impact of CT-based attenuation and scatter correction on myocardial SPECT images
    van Dalen, J. A.
    Sellis, M.
    de Bruin, W. I.
    Wyndaele, D. N. J.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S286 - S286
  • [9] A method for attenuation and scatter correction of brain SPECT based on computed tomography images
    Larsson, A
    Johansson, L
    Sundström, T
    Åhlström, KR
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) : 411 - 420
  • [10] A transmission-map-based scatter correction technique for SPECT in inhomogeneous media
    University of Utah, Salt Lake City, UT 84132, United States
    MED. PHYS., 10 (1627-1635):