Development and evaluation of a liquid chromatography-mass spectrometry method for rapid, accurate quantitation of malondialdehyde in human plasma

被引:23
|
作者
Sobsey, Constance A. [1 ,2 ]
Han, Jun [1 ]
Lin, Karen [1 ]
Swardfager, Walter [3 ]
Levitt, Anthony [4 ]
Borchers, Christoph H. [1 ,2 ,5 ]
机构
[1] Univ Victoria, Genome BC Prote Ctr, Vancouver Isl Technol Pk,3101-4464 Markham St, Victoria, BC V8Z 7X8, Canada
[2] Univ Victoria, Dept Biochem & Microbiol, Petch Bldg Room 207,3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[3] Sunnybrook Hlth Sci Ctr, Dept Pharmacol & Toxicol, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[4] Sunnybrook Hlth Sci Ctr, Dept Psychiat, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[5] McGill Univ, Jewish Gen Hosp, Segal Canc Ctr, 3755 Cote Ste Catherine Rd, Montreal, PQ H3T 1E2, Canada
关键词
Malondialdehyde; Plasma; 3-Nitrophenylhydrazine; Derivatization; LC/MRM-MS; Isotope-labeling; OXIDATIVE STRESS; LIPID-PEROXIDATION; PERFORMANCE; ALDEHYDES; DERIVATIZATION; HOMOCYSTEINE; PATHOGENESIS; SYMPTOMS; DISEASE; ACID;
D O I
10.1016/j.jchromb.2016.07.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Malondialdhyde (MDA) is a commonly used marker of lipid peroxidation in oxidative stress. To provide a sensitive analytical method that is compatible with high throughput, we developed a multiple reaction monitoring-mass spectrometry (MRM-MS) approach using 3-nitrophenylhydrazine chemical derivatization, isotope-labeling, and liquid chromatography (LC) with electrospray ionization (ESI)-tandem mass spectrometry assay to accurately quantify MDA in human plasma. A stable isotope-labeled internal standard was used to compensate for ESI matrix effects. The assay is linear (R-2=0.9999) over a 20,000-fold concentration range with a lower limit of quantitation of 30 fmol (on-column). Intra- and inter-run coefficients of variation (CVs) were <2% and similar to 10% respectively. The derivative was stable for >36 h at 5 degrees C. Standards spiked into plasma had recoveries of 92-98%. When compared to a common LC-UV method, the LC-MS method found near-identical MDA concentrations. A pilot project to quantify MDA in patient plasma samples (n = 26) in a study of major depressive disorder with winter-type seasonal pattern (MDD-s) confirmed known associations between MDA concentrations and obesity (p < 0.02). The LC-MS method provides high sensitivity and high reproducibility for quantifying MDA in human plasma. The simple sample preparation and rapid analysis time (5x faster than LC-UV) offers high throughput for large-scale clinical applications. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 50 条
  • [1] Rapid quantitation of cyclophosphamide metabolites in plasma by liquid chromatography-mass spectrometry
    Kalhorn, TF
    Howald, WN
    Cole, S
    Phillips, B
    Wang, J
    Slattery, JT
    McCune, JS
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2): : 105 - 113
  • [2] Selective and rapid liquid chromatography-mass spectrometry method for the determination of lercanidipine in human plasma
    Salem, II
    Idrees, J
    Al Tamimi, JI
    Farina, P
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 803 (02): : 201 - 207
  • [3] Rapid and sensitive liquid chromatography-mass spectrometry method for determination of ropinirole in human plasma
    Bhatt, J
    Jangid, A
    Shetty, R
    Shah, B
    Kambli, S
    Subbaiah, G
    Singh, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (05) : 1202 - 1208
  • [4] Development and validation of liquid chromatography-mass spectrometry method for the determination of telmisartan in human plasma
    Chen, BM
    Liang, YZ
    Wang, YL
    Deng, FL
    Zhou, P
    Guo, FQ
    Huang, LF
    [J]. ANALYTICA CHIMICA ACTA, 2005, 540 (02) : 367 - 373
  • [5] Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry
    Bansal, Sukhvinder S.
    Halket, John M.
    Bomford, Adrian
    Simpson, Robert J.
    Vasavda, Nisha
    Thein, Swee Lay
    Hider, Robert C.
    [J]. ANALYTICAL BIOCHEMISTRY, 2009, 384 (02) : 245 - 253
  • [6] A liquid chromatography-mass spectrometry method for the quantitation of aristololactam-I in rat plasma
    Ling, Zhen
    Jiang, Zhen-zhou
    Huang, Xin
    Zhang, Lu-yong
    Xu, Xiao-yue
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) : 10 - 14
  • [7] Sensitive liquid chromatography-mass spectrometry assay for quantitation of docetaxel and paclitaxel in human plasma
    Parise, RA
    Ramanathan, RK
    Zamboni, WC
    Egorin, MJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01): : 231 - 236
  • [8] Quantitation of paracetamol by liquid chromatography-mass spectrometry in human plasma in support of clinical trial
    Kam, Richard Kin-Ting
    Chan, Michael Ho-Ming
    Wong, Hiu-Ting
    Ghose, Aniruddha
    Dondorp, Arjen M.
    Plewes, Katherine
    Tarning, Joel
    [J]. FUTURE SCIENCE OA, 2018, 4 (08):
  • [9] Liquid chromatography-mass spectrometry method for the determination of nicardipine in human plasma
    Qi, ML
    Wang, P
    Xin, J
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 81 - 85
  • [10] A RAPID AND SENSITIVE METHOD FOR THE QUANTITATION OF MONTELUKAST IN HUMAN PLASMA USING LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY
    Gunasakaran, S.
    Rao, Nageshwara
    Arunkumar, S.
    Olaganathan, A.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2010, 1 (10): : 65 - 72