In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques

被引:0
|
作者
Ural, Cagri [1 ]
Burgaz, Yavuz [2 ]
Sarac, Duygu [1 ]
机构
[1] Ondokuz Mayis Univ, Fac Dent, Dept Prosthodont, Samsun, Turkey
[2] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
来源
QUINTESSENCE INTERNATIONAL | 2010年 / 41卷 / 07期
关键词
all-ceramic; CAD/CAM; marginal discrepancy; marginal fit; PROCERA ALLCERAM CROWNS; FINISH LINES; CAD-CAM; FIT; SYSTEMS; DISCREPANCIES; MICROLEAKAGE; ACCURACY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare in vitro the marginal adaptation of crowns manufactured using ceramic restoration fabricating techniques. Method and Materials: Fifty standardized master steel dies simulating molars were produced and divided into five groups, each containing 10 specimens. Test specimens were fabricated with CAD/CAM, heat-press, glass-infiltration, and conventional lost-wax techniques according to manufacturer instructions. Marginal adaptation of the test specimens was measured vertically before and after cementation using SEM. Data were statistically analyzed by one-way ANOVA with Tukey HSD tests (alpha = .05). Results: Marginal adaptation of ceramic crowns was affected by fabrication technique and cementation process (P < .001). The lowest marginal opening values were obtained with Cerec-3 crowns before and after cementation (P < .001). The highest marginal discrepancy values were obtained with PFM crowns before and after cementation. Conclusion: Marginal adaptation values obtained in the compared systems were within clinically acceptable limits. Cementation causes a significant increase in the vertical marginal discrepancies of the test specimens. (Quintessence Int 2010;41:585-590)
引用
收藏
页码:585 / 590
页数:6
相关论文
共 50 条
  • [1] Marginal adaptation of ceramic overlays in vitro.
    Peikert, A
    Schuckar, M
    Geurtsen, W
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 128 - 128
  • [2] Marginal adaptation and fit of ceramic overlays in vitro.
    Munack, J
    Schuckar, M
    Geurtsen, W
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1428 - 1428
  • [3] Marginal adaptation of ceramic veneers to dentin in vitro.
    Christgau, M
    Friedl, KH
    Schmalz, G
    Hiller, KA
    Resch, U
    Bader, N
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1429 - 1429
  • [4] Evaluation of marginal adaptation of ceramic crowns depending on the marginal design and the addition of ceramic.
    Hilgert, E.
    Neisser, M. P.
    Vasquez, V. Z. C.
    Costa, E. M. V.
    Giannini, V.
    Bondioli, I. R.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B329 - B329
  • [5] MARGINAL ADAPTATION EVALUATION OF GLASS CERAMIC CAST CROWNS
    KNELLESEN, C
    FLEITER, B
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 552 - 552
  • [6] IN-VITRO MARGINAL ADAPTATION OF ALUMINA PORCELAIN CERAMIC CROWNS
    PERA, P
    GILODI, S
    BASSI, F
    CAROSSA, S
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (06): : 585 - 590
  • [7] Determination of the fabricating conditions for the preferable marginal and internal adaptation of the mica crystal castable ceramic crown
    Ukon, S
    Ishikawa, M
    Tohyama, M
    Sato, H
    DENTAL MATERIALS JOURNAL, 2004, 23 (01) : 53 - 62
  • [8] EVALUATION OF MARGINAL ADAPTATION OF ALL-CERAMIC CROWNS AND METAL CERAMIC CROWNS
    VAHIDI, F
    EGLOFF, ET
    PANNO, FV
    JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (04): : 426 - 431
  • [9] COMPARISON OF TECHNIQUES FOR THE EVALUATION OF MARGINAL ADAPTATION OF AMALGAM RESTORATIONS
    MJOR, IA
    RYGE, G
    INTERNATIONAL DENTAL JOURNAL, 1981, 31 (01) : 1 - 5
  • [10] In vitro evaluation of marginal microleakage and adaptation of metal-ceramic crowns luted with three types of cements.
    Motta, B
    Pegoraro, LF
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B183 - B183