Vent pipe emissions from storage tanks at gas stations: Implications for setback distances

被引:16
|
作者
Hilpert, Markus [1 ]
Rule, Ana Maria [2 ]
Adria-Mora, Bernat [1 ]
Tiberi, Tedmund [3 ]
机构
[1] Columbia Univ, Mailman Sch Publ Hlth, Dept Environm Hlth Sci, 722 West 168th St, New York, NY 10032 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Environm Hlth & Engn, Baltimore, MD 21205 USA
[3] ARID Technol Inc, Wheaton, IL 60187 USA
关键词
Gas stations; Benzene emissions; Setback distances; Air pollution modeling; Measurements; ACUTE CHILDHOOD LEUKEMIA; HEALTH-RISK ASSESSMENT; IN-SERVICE STATIONS; PETROL STATIONS; VAPOR RECOVERY; AMBIENT AIR; EXPOSURE; BENZENE; PROXIMITY; BTEX;
D O I
10.1016/j.scitotenv.2018.09.303
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At gas stations, fuel vapors are released into the atmosphere from storage tanks through vent pipes. Little is known about when releases occur, their magnitude, and their potential health consequences. Our goals were to quantify vent pipe releases and examine exceedance of short-term exposure limits to benzene around gas stations. At two US gas stations, we measured volumetric vent pipe flow rates and pressure in the storage tank head-space at high temporal resolution for approximately three weeks. Based on the measured vent emission and meteorological data, we performed air dispersion modeling to obtain hourly atmospheric benzene levels. For the two gas stations, average vent emission factors were 0.17 and 0.21 kg of gasoline per 1000 L dispensed. Modeling suggests that at one gas station, a 1-hour Reference Exposure Level (REL) for benzene for the general population (8 ppb) was exceeded only closer than 50 m from the station's center. At the other gas station, the REL was exceeded on two different days and up to 160 m from the center, likely due to non-compliant bulk fuel deliveries. A minimum risk level for intermediate duration (> 14-364 days) benzene exposure (6 ppb) was exceeded at the elevation of the vent pipe opening up to 7 and 8 m from the two gas stations. Recorded vent emission factors were >10 times higher than estimates used to derive setback distances for gas stations. Setback distances should be revisited to address temporal variability and pollution controls in vent emissions. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:2239 / 2250
页数:12
相关论文
共 50 条
  • [1] EMISSIONS FROM STORAGE TANKS
    NITSCHE, M
    ERDOL & KOHLE ERDGAS PETROCHEMIE, 1981, 34 (04): : 167 - 171
  • [2] Estimation of Benzene from Storage Tanks and Determination of the Permissible Distance from Gas Stations
    Chehrehei, Maryam
    MirzaHosseini, Seyed Alireza Haji Seyed
    Mansouri, Nabiollah
    Behzadi, Mohammad Hassan
    Rashidi, Yousef
    POLLUTION, 2023, 9 (02): : 745 - 755
  • [3] Control emissions from aboveground storage tanks
    Brown, C
    Dixon, P
    CHEMICAL ENGINEERING PROGRESS, 1996, 92 (05) : 42 - 47
  • [4] The dispersion of fugitive emissions from storage tanks
    Hort, MC
    Robbins, AG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2002, 90 (11) : 1321 - 1348
  • [5] Performance analysis of liquefied natural gas storage tanks in refueling stations
    Sharafian, Amir
    Herrera, Omar E.
    Merida, Walter
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 36 : 496 - 509
  • [6] Methane emissions from oil and gas production sites and their storage tanks in West Virginia
    Johnson, Derek
    Clark, Nigel
    Heltzel, Robert
    Darzi, Mahdi
    Footer, Tracey L.
    Herndon, Scott
    Thoma, Eben D.
    ATMOSPHERIC ENVIRONMENT-X, 2022, 16
  • [7] Fugitive gas emissions from fuel tanks
    Cisse, P
    Karim, GA
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2006, 3 (01) : 91 - 100
  • [8] Volatile Emissions from Hot Bitumen Storage Tanks
    Deygout, Francois
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2011, 30 (01) : 102 - 112
  • [9] CONTROL OF ATMOSPHERIC EMISSIONS FROM PETROLEUM STORAGE TANKS
    不详
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1971, 21 (05): : 260 - &
  • [10] Fugitive emissions estimation from petroleum storage tanks
    Chakradhar, Bandari