摘要
A mixed-signal ASIC for timing and energy measurements with radiation detectors is described. The chip embeds 64 channels, each of which features a charge-sensitive amplifier followed by a dual-shaper coupled to low-offset discriminators. A versatile back-end, incorporating low-power Time to Digital Converters and Wilkinson Analog to Digital Converters with derandomizing buffers allows to encode both the time of arrival and the charge of the input signal. The ASIC is designed for a maximum detector capacitance of 100 pF and an event rate in excess of 60 kHz per channel. A peak detector samples the input signal with an excellent linearity in the range 5 divided by 55 fC. Charge digitization with Time-over-Threshold is also supported to extend the dynamic range. Fabricated in a 110 nm CMOS process, the chip dissipates 10 mW/channel. The ASIC was primarily developed to readout the cylindrical GEM detector of the BESIII experiment. For its characteristics it can serve however a broad class of radiation sensors, including silicon microstrip detectors.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [1] Design and Test Results of a Front-end ASIC for Radiation Detectors
    Zhang Yacong
    Chen Zhongjian
    Lu Wengao
    Ji Lijiu
    Zhao Baoying
    [J]. 2008 9TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED-CIRCUIT TECHNOLOGY, VOLS 1-4, 2008, : 1709 - 1712
  • [2] Front-end electronics for energy and position measurements with semiconductor radiation detectors
    Re, V
    [J]. INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 1999, 29 (01): : 20 - 25
  • [3] Front-end ASIC for germanium strip detectors
    Wulf, E. A.
    Hou, W.
    De Geronimo, G.
    Roberts, J. M.
    Boggs, S. E.
    Phlips, B. F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [4] A Multi-Channel Front-End ASIC for Pixellated Detectors
    Deng, Zhi
    Liu, Yinong
    Zhang, Lan
    Li, Yulan
    Li, Yuanjing
    Li, Jin
    Lan, Allan Kejian
    Hungerford, Ed
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 337 - 340
  • [5] The RatCAP Front-End ASIC
    Pratte, Jean-Francois
    Junnarkar, Sachin
    Deptuch, Grzegorz
    Fried, Jack
    O'Connor, Paul
    Radeka, Veljko
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    Stoll, Sean
    Maramraju, Sri Harsha
    Krishnamoorthy, Srilalan
    Lecomte, Roger
    Fontaine, Rejean
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2727 - 2735
  • [6] The RatCAP front-end ASIC
    Pratte, Jean-Francois
    Junnarkar, Sachin
    Deptuch, Grzegorz
    Fried, Jack
    O'Connor, Paul
    Radeka, Veljko
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    Stoll, Sean
    Maramraju, Sri Harsha
    Krishnamoorthy, Srilalan
    Lecomte, Roger
    Fontaine, Rejean
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 19 - 25
  • [7] A front-end ASIC for use with large-pixel array detectors
    Jagadish, U
    Britton, CL
    Bryan, WL
    Garber, FW
    Walter, J
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 576 - 579
  • [8] Characterization of an ASIC Front-End electronics dedicated to the Silicon Drift Detectors
    Labanti, C.
    Baldazzi, G.
    Malcovati, P.
    Bertuccio, G.
    Feroci, M.
    Zampa, G.
    Grassi, M.
    Picolli, L.
    Evangelista, Y.
    Fuschino, F.
    Marisaldi, M.
    Morelli, E.
    Campana, R.
    Del Monte, E.
    Pacciani, L.
    Muleri, F.
    Costa, E.
    Donnarumma, I.
    Lazzarotto, F.
    Rapisarda, M.
    Rubini, A.
    Soffitta, P.
    Zampa, N.
    Rashevsky, A.
    Vacchi, A.
    Cappelli, S.
    Navarria, F.
    Rossi, P.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 648 - 652
  • [9] Development of a low-noise front-end ASIC for CdTe detectors
    Kawamura, Tenyo
    Orita, Tadashi
    Takeda, Shin'ichiro
    Watanabe, Shin
    Ikeda, Hirokazu
    Takahashi, Tadayuki
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982
  • [10] BASIC32_ADC, a Front-end ASIC for SiPM Detectors
    Ciciriello, F.
    Corsi, F.
    Licciulli, F.
    Marzocca, C.
    Matarrese, G.
    Chesi, E.
    Nappi, E.
    Rudge, A.
    Seguinot, J.
    Del Guerra, A.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,