Inter-observer and Intra-observer Variability in Volume Measurements of the Lower Extremity Using Perometer

被引:8
|
作者
Reza, Carni [1 ]
Norregaard, Susan [1 ]
Moffatt, Christine [1 ]
Karlsmark, Tonny [1 ]
机构
[1] Bispebjerg Hosp, Copenhagen Wound Healing Ctr, Dept Dermatovenerol, Bispebjerg Bakke 24, DK-2400 Copenhagen, Denmark
关键词
lymphedema; volume measurements; lower extremities; Perometer; CANCER-RELATED LYMPHEDEMA; LIMB; RELIABILITY; AGREEMENT;
D O I
10.1089/lrb.2019.0063
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The swelling of the extremities seen in lymphedema can be measured with many different volumetric devices; however, many methods lack important characteristics including reproducibility and independence from the subjectivity and skill of the operator. The aim of this study was to validate the use of the Perometer(R) as a possible standard for volumetric measurement methods based on the inter-observer and intra-observer variability when using a standard method of Perometry(R). Methods and Results: Volumetric measurements were performed on 10 healthy test subjects by 5 individuals (the observers) who had been instructed in the measurement techniques to be used. The inter-observer variability was assessed by having the five observers measure all the test subjects both in the morning and in the early afternoon. The intra-observer variability was examined by having each observer measure all the 10 test subjects 4 times in a row in the aforementioned time frames. A data set was created using the measurements, allowing for the assessment of other parameters including variation of volume between the right and left leg and daily variation in swelling. Statistical measurements were performed using the Statistical Package for the Social Sciences (SPSS), from which it was determined that there was no statistically significant inter-observer (p-value 0.997) and intra-observer variation (p-value 0.995) based on a significance level of >5%. Furthermore, it was observed that a statistically significant difference in volume occurred in the leg volume during the day. Conclusion: It was concluded that the use of the Perometer provides consistent measurements of volume independent of the observer and therefore appears to provide a candidate standard for volumetric measurements.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 50 条
  • [1] Inter-observer and intra-observer variability in hepatology
    Winkfield, B
    Aubé, C
    Burtin, P
    Calès, P
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2003, 15 (09) : 959 - 966
  • [2] Intra-Observer and Inter-Observer Variability of Intraocular Lens Measurements Using an Interferometry Metrology Device
    Stern, Benjamin
    Saad, Alain
    Flamant, Roxane
    Joannes, Luc
    Gatinel, Damien
    [J]. DIAGNOSTICS, 2024, 14 (02)
  • [3] Intra-observer and inter-observer variability of clinical annotations of monitoring data
    M Imhoff
    R Fried
    U Gather
    S Siebig
    C Wrede
    [J]. Critical Care, 11 (Suppl 2):
  • [4] INTER-OBSERVER AND INTRA-OBSERVER VARIABILITY IN THE INTERPRETATION OF THE DISCRETE CHARACTERS OF THE SKULL
    DESTEFANO, GF
    AUEHAUSER, G
    GUIDOTTI, A
    ROSSI, S
    GUALANDI, PB
    [J]. JOURNAL OF HUMAN EVOLUTION, 1983, 12 (08) : 690 - 690
  • [5] Assessment of inter-observer and intra-observer variability in the measurement of QT dispersion
    Bhullar, HK
    Chia, P
    Ong, K
    Ng, WL
    [J]. COMPUTERS IN CARDIOLOGY 1996, 1996, : 297 - 300
  • [6] Inter-observer and Intra-observer Reliability of Measurements of the Obliquity of Palpebral Fissures
    Davis, Amy Livingston
    Twelker, John Daniel
    Miller, Joseph M.
    Harvey, Erin M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Intra-observer, inter-observer and inter-scanner variations in brain MRI volume measurements in multiple sclerosis
    Gasperini, C
    Rovaris, M
    Sormani, MP
    Bastianello, S
    Pozzilli, C
    Comi, G
    Filippi, M
    [J]. MULTIPLE SCLEROSIS, 2001, 7 (01): : 27 - 31
  • [8] An evaluation of the inter-observer and intra-observer variability of the ultrasound diagnosis of polycystic ovaries
    Amer, SAKS
    Li, TC
    Bygrave, C
    Sprigg, A
    Saravelos, H
    Cooke, ID
    [J]. HUMAN REPRODUCTION, 2002, 17 (06) : 1616 - 1622
  • [9] Intra-observer and inter-observer variation of Hertel exophthalmometry
    Lam, Andrew K. C.
    Lam, Chun-fai
    Leung, Wai-kit
    Hung, Pui-kwan
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (04) : 472 - 476
  • [10] INTRA-OBSERVER AND INTER-OBSERVER VARIABILITY OF ECHO-DOPPLER MEASUREMENTS OF PORTAL FLOW IN NORMAL VOLUNTEERS
    SABBA, C
    NAKAMURA, T
    WELTIN, GC
    CICCHETTI, DR
    MORIYASU, F
    TAYLOR, KJW
    GROSZMANN, RJ
    [J]. HEPATOLOGY, 1988, 8 (05) : 1244 - 1244