A 3D positioning method for radiotherapy treatment

被引:0
|
作者
Su, L [1 ]
Liu, XL [1 ]
机构
[1] Beijing Inst Technol, Dept Electroopt Engn, Beijing 100081, Peoples R China
关键词
3D positioning; range image; radiotherapy treatment; correspondence problem;
D O I
10.1117/12.317874
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new method of 3D multi-spot surface profiling for patient's positioning is presented In this paper. In the approach, an encoded pattern structured light is used to project onto the target to be positioned, which is typically part of the patient surface. A single camera is used to image the projected light beams and the range data from camera to the target points can be extracted from the image of the deformed pattern. Because the light pattern is encoded, the correspondence between the projected beams and imaged beams is easily determined and, hence, the range data can be calculated quickly The 3D sensing method here is based on the active light illumination triangulation. A detail description of the method is given, including system configuration, algorithms for solving the correspondence problem, reconstruction of the paint's 3D position, calibration and experimental results, etc. One of the features of the system is extremely simplicity in hardware. And there is no movement part in the system. The encoded grid beam pattern makes it possible to solve the problem of the correspondence between the illuminated spots on the patient and their image points on the image plane. Also, the 3D reconstructed coordinates can be obtained from only one picture frame captured and the time consuming for computer is reasonably reduced.
引用
收藏
页码:224 / 233
页数:10
相关论文
共 50 条
  • [1] 3D Ultrasound-based patient positioning for radiotherapy
    Wang, Michael H.
    Rohling, Robert N.
    Archip, Neculai
    Clark, Brenda G.
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [2] A method of 3D target reconstruction in stereotactic radiotherapy
    Petrascu, O
    Theodorou, K
    Kappas, K
    Mazal, DA
    [J]. BALKAN CONGRESS OF ONCOLOGY, 1996, : 333 - 337
  • [3] COMPUTER PROCEDURES IN 3D RADIOTHERAPY TREATMENT PLANNING
    HOSS, A
    DUBUS, J
    BENDL, R
    ENGENHARTCABILLIC, R
    SCHLEGEL, W
    [J]. RADIOLOGE, 1995, 35 (09): : 583 - 586
  • [4] A 3D Fingerprinting Positioning Method Based on Cellular Networks
    Wang, Yao-hui
    Li, Hu
    Luo, Xin-long
    Sun, Qi-ming
    Liu, Jin-nan
    [J]. INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2014,
  • [5] INFLUENCE OF THE POSITIONING ERROR ON 3D CONFORMAL DOSE DISTRIBUTIONS DURING FRACTIONATED RADIOTHERAPY
    RUDAT, V
    FLENTJE, M
    OETZEL, D
    MENKE, M
    SCHLEGEL, W
    WANNENMACHER, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 33 (01) : 56 - 63
  • [6] 3D CT simulation and treatment planning system for radiotherapy
    Yang, YL
    Liu, Q
    [J]. ICIA 2004: PROCEEDINGS OF 2004 INTERNATIONAL CONFERENCE ON INFORMATION ACQUISITION, 2004, : 436 - 439
  • [7] qDose, a 3D Treatment Planning System for Molecular Radiotherapy
    Bacelar, A. M. Denis
    Chittenden, S.
    Divoli, A.
    Gear, J.
    Flux, G.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S351 - S351
  • [8] Method for error compensation of time reference in ultrasonic 3D positioning
    Yan X.-Z.
    Wang H.-Y.
    Wang X.
    [J]. Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2019, 49 (02): : 640 - 646
  • [9] Positioning Method of Tomato Pollination Flowers Based on 3D Vision
    Wen C.
    Long J.
    Zhang Y.
    Guo W.
    Lin S.
    Liang X.
    [J]. Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2022, 53 (08): : 320 - 328
  • [10] An Indoor UWB 3D Positioning Method for Coplanar Base Stations
    Zhou, Ning
    Si, Minghao
    Li, Dehai
    Seow, Chee Kiat
    Mi, Jinzhong
    [J]. SENSORS, 2022, 22 (24)