Factory-calibrated continuous glucose monitoring and capillary blood glucose monitoring in a case with insulinoma: usefulness and possible pitfall under chronic hyperinsulinemic hypoglycemia

被引:4
|
作者
Suminaga, Keiichiro [1 ]
Murakami, Takaaki [1 ]
Yabe, Daisuke [1 ,2 ]
Sone, Masakatsu [1 ]
Sugawa, Taku [3 ]
Masui, Toshihiko [4 ]
Uza, Norimitsu [5 ]
Yoshizawa, Akihiko [6 ]
Ogura, Masahito [1 ]
Yasoda, Akihiro [1 ,3 ]
Inagaki, Nobuya [1 ]
机构
[1] Kyoto Univ, Dept Diabet Endocrinol & Nutr, Grad Sch Med, Kyoto, Japan
[2] Gifu Univ, Dept Diabet & Endocrinol, Grad Sch Med, Gifu, Japan
[3] Natl Hosp Org Kyoto Med Ctr, Dept Endocrinol & Metab, Kyoto, Japan
[4] Kyoto Univ, Dept Hepatobiliary Pancreat Surg & Transplantat, Grad Sch Med, Kyoto, Japan
[5] Kyoto Univ, Dept Gastroenterol & Hepatol, Grad Sch Med, Kyoto, Japan
[6] Kyoto Univ, Dept Diagnost Pathol, Grad Sch Med, Kyoto, Japan
关键词
Insulinoma; Flash glucose monitoring; Continuous glucose monitoring; Hypoglycemia; Hypoglycemia unawareness; DIAGNOSIS;
D O I
10.1507/endocrj.EJ19-0339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of factory-calibrated continuous glucose monitoring (fCGM) within hypoglycemic ranges, especially under the status of chronic hyperinsulinemic hypoglycemia like insulinomas, remains an issue. Even so, fCGM is known to be useful for detecting hypoglycemia unawareness in insulinoma cases. A 25-year-old woman presenting with sudden unconsciousness was diagnosed with insulinoma; ICGM facilitated diagnosis by continuous monitoring for hypoglycemia. Before surgery, she was treated with continuous and frequent bolus infusions of 50% glucose via central venous catheter. To evaluate the accuracy of fCGM values in this case, a comparison between fCGM and capillary blood glucose (CBG) values was also performed. According to the simultaneously measured values, those of ICGM were largely in accordance with those of CBG. Moreover, compared with the previously reported case not having glucose infusions via central venous catheter, both the mean absolute relative differences (MARDs) and the absolute differences (Delta glucose) between MGM and CBG values were larger in the present case, although no significant differences of MARDs and Delta glucose between the two cases were observed in several different conditions including fasting, post-meal, hypoglycemia, and others. Therefore, we should note possible increased differences between fCGM and CBG values in cases using frequent intravenous glucose infusions as well as case-dependent differing levels of consistency between them.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 50 条
  • [1] Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
    Aida, Azusa
    Noto, Hiroshi
    AMERICAN JOURNAL OF CASE REPORTS, 2022, 23
  • [2] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [3] Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia
    Nishimura, Eri
    Oka, Shuntaro
    Ozawa, Junichi
    Tanaka, Kosuke
    Momose, Taichi
    Kabe, Kazuhiko
    Namba, Fumihiko
    TURKISH ARCHIVES OF PEDIATRICS, 2021, 56 (02): : 115 - 120
  • [4] Continuous Glucose Monitoring in Subcutaneous Tissue Using Factory-Calibrated Sensors: A Pilot Study
    Hoss, Udo
    Jeddi, Iman
    Schulz, Mark
    Budiman, Erwin
    Bhogal, Claire
    McGarraugh, Geoffrey
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (08) : 591 - 597
  • [5] Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes
    Frank, Spencer
    Hames, Kazanna C.
    Jbaily, Abdulrahman
    Park, Jee Hye
    Stroyeck, Chuck
    Price, David
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (12) : 907 - 914
  • [6] Consistent Accuracy over 10 Days with a Factory-Calibrated Continuous Glucose Monitoring System in Children and Adults
    Zhang, Xiaohe
    Johnson, Terri
    Price, David A.
    Balo, Andrew
    DIABETES, 2018, 67
  • [7] Development of an Error Model for a Factory-Calibrated Continuous Glucose Monitoring Sensor with 10-Day Lifetime
    Vettoretti, Martina
    Battocchio, Cristina
    Sparacino, Giovanni
    Facchinetti, Andrea
    SENSORS, 2019, 19 (23)
  • [8] Performance of a factory-calibrated, real-time continuous glucose monitoring system during elective abdominal surgery
    Tripyla, Afroditi
    Herzig, David
    Joachim, Dehais
    Nakas, Christos T.
    Amiet, Franziska
    Andreou, Andreas
    Gloor, Beat
    Vogt, Andreas
    Bally, Lia
    DIABETES OBESITY & METABOLISM, 2020, 22 (09): : 1678 - 1682
  • [9] Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System
    Ji, Linong
    Guo, Lixin
    Zhang, Junqing
    Li, Yufeng
    Chen, Zhiyan
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 208 - 213
  • [10] CLINICAL USEFULNESS OF CONTINUOUS GLUCOSE MONITORING IN HYPOGLYCEMIA DETECTION
    Moreno-Fernandez, J.
    Garcia-Seco, J. A.
    Garcia-Seco, F.
    Lozano-Serrano, M.
    Seco, A. M.
    Lozano, C.
    Aguirre, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A82 - A82