The microbiological quality of seven large commercial private water supplies in the United Kingdom

被引:19
|
作者
Kay, D. [1 ]
Watkins, J.
Francis, C. A.
Wyn-Jones, A. P.
Stapleton, C. M.
Fewtrell, L.
Wyer, M. D.
Drury, D.
机构
[1] Univ Wales, River basin Dynam & Hydrol Res Grp, Aberystwyth SY23 3DB, Dyfed, Wales
[2] CREH Analyt, Leeds LS18 4RS, W Yorkshire, England
[3] Drinking Water Inspectorate, London SW1A 2EY, England
关键词
faecal indicators; large private water supplies; pathogen; rainfall; waterborne disease; water quality;
D O I
10.2166/wh.2007.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Some 1% of the UK population derives their potable water from 140,000 private water supplies (PWSs) regulated by Local Authorities. The overwhelming majority of these are very small domestic supplies serving a single property or a small number of properties. Treatment for such supplies is rudimentary or non-existent and their microbiological quality has been shown to be poor in every published study to date. Private water supplies serving commercial enterprises such as hotels, restaurants, food production premises and factories are more frequently treated and subject to closer regulation in the United Kingdom. As a result, it has been assumed that these larger commercial supplies are less likely to experience elevated faecal indicator and pathogen concentrations at the consumer tap which have been observed at small domestic supplies. This paper reports on intensive monitoring at seven commercial private water supplies (six of which were treated) spread throughout the UK serving hotels, holiday parks and food production enterprises. Daily sampling of 'potable' water, both at the consumer tap and using large volume filtration for Giardia and Cryptosporidium spp. was conducted over two six week periods in the spring and autumn of 2000. This allowed the effects of short term episodic peaks in faecal indicator and pathogen concentration to be quantified. All the supplies experienced intermittent pathogen presence and only one, a chlorinated deep borehole supply, fully complied with UK water quality regulations during both periods of sampling. Poor microbiological water quality typically followed periods of heavy rainfall. This suggests that the design and installation of such systems should be undertaken only after the likely range of raw water quality has been characterised, which requires a thorough understanding of the effects of flow and seasonality on raw water quality. There is no reason to suspect that the monitored sites are uncharacteristic of other commercial supplies and the results reinforce public health concerns related to domestic supplies. Furthermore, the pattern of contamination is highly episodic, commonly lasting only a few days. Thus, the relatively infrequent regulatory monitoring of such supplies would be unlikely to identify the poor water quality episodes and does not provide the data necessary for public health protection. Although some statistical relationship was found between faecal indicator organisms and the presence of pathogens, the use of FIOs in assessments of regulatory compliance may not always provide a reliable measure of public health risk, i.e. indicator absence does not preclude pathogen presence. The results of this study suggest that a risk assessment system similar to the WHO 'Water Safety Planning' approach might offer a more appropriate regulatory paradigm for private water supplies.
引用
收藏
页码:523 / 538
页数:16
相关论文
共 50 条
  • [1] The microbiological quality of private water supplies
    Fewtrell, L
    Kay, D
    Godfree, A
    [J]. JOURNAL OF THE CHARTERED INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1998, 12 (02): : 98 - 100
  • [2] The microbiological quality of private water supplies
    Fewtrell, L
    Kay, D
    Godfree, A
    [J]. JOURNAL OF THE CHARTERED INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1998, 12 (01): : 45 - 47
  • [3] A survey of the microbiological quality of private water supplies in England
    Rutter, M
    Nichols, GL
    Swan, A
    De Louvois, J
    [J]. EPIDEMIOLOGY AND INFECTION, 2000, 124 (03): : 417 - 425
  • [4] Chemical contamination of private drinking water supplies in the West Midlands, United Kingdom
    Harrison, WN
    Bradberry, SM
    Vale, JA
    [J]. JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2000, 38 (02): : 137 - 144
  • [5] Microbiological water quality requirements for salad irrigation in the United Kingdom
    Tyrrel, S. F.
    Knox, J. W.
    Weatherhead, E. K.
    [J]. JOURNAL OF FOOD PROTECTION, 2006, 69 (08) : 2029 - 2035
  • [6] Microbiological surveillance of private water supplies in England - The impact of environmental and climate factors on water quality
    Richardson, Hopi Yip
    Nichols, Gordon
    Lane, Chris
    Lake, Iain R.
    Hunter, Paul R.
    [J]. WATER RESEARCH, 2009, 43 (08) : 2159 - 2168
  • [7] MICROBIOLOGICAL QUALITY OF PUBLIC WATER-SUPPLIES
    COLBOURNE, JS
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1983, 55 (03): : R7 - R7
  • [8] NITRATE AND WATER-SUPPLIES IN THE UNITED-KINGDOM
    CROLL, BT
    HAYES, CR
    [J]. ENVIRONMENTAL POLLUTION, 1988, 50 (1-2) : 163 - 187
  • [9] Microbiological assessment of private drinking water supplies in Co. Cork, Ireland
    Bacci, Fabio
    Chapman, Deborah V.
    [J]. JOURNAL OF WATER AND HEALTH, 2011, 9 (04) : 738 - 751
  • [10] THE UNITED-KINGDOM NATIONAL MICROBIOLOGICAL QUALITY ASSESSMENT SCHEME
    SNELL, JJS
    DEMELLO, JV
    GARDNER, PS
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1982, 35 (01) : 82 - 93