Electrochemical properties of a tetrabromo-p-benzoquinone modified carbon paste electrode.: Application to the simultaneous determination of ascorbic acid, dopamine and uric acid

被引:258
|
作者
Zare, HR [1 ]
Nasirizadeh, N [1 ]
Mazloum-Ardakani, M [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
tetrabromo-p-benzoquinone; carbon paste electrode; ascorbic acid; dopamine; uric acid; electrocatalytic oxidation;
D O I
10.1016/j.jelechem.2004.11.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical study of a tetra bromo-p-benzoquinone modified carbon paste electrode (TBQ-MCPE), as well as its efficiency for electrocatalytic oxidation of ascorbic acid, dopamine and uric acid, is described. Cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution pH values and at various scan rates. Three linear segments were found with slope values of -58.4 mV/pH, -28.1 mV/pH and 0.0 mV/pH in the pH range 2.0-7.1, pH 7.1-9.0 and pH 9.0-11.0, respectively. The apparent charge transfer rate constant, k(s), and transfer coefficient, a, for electron transfer between TBQ and CPE were calculated as 3.79 +/- 0.10 s(-1) and 0.55, respectively. The electrode was also employed to study the electrocatalytic oxidation of AA, using cyclic voltammetry, chronoamperometry and differential pulse voltammetry as diagnostic techniques. It has been found that the oxidation of AA at the surface of TBQ-MCPE occurs at a potential of about 430 mV less positive than that of an unmodified CPE. The diffusion coefficient of AA was also estimated using chronoamperometry. The kinetic parameters such as the electron transfer coefficient, alpha, and heterogeneous rate constant, k(h)', for oxidation of AA at the TBQ-MCPE surface was determined using cyclic voltammetry. Differential pulse voltammetry (DPV) exhibits two linear dynamic ranges and a detection limit of 0.62 mu M for AA. In DPV, the TBQ-MCPE could separate the oxidation peak potentials of AA, DA and UA present in the same solution, though at the unmodified CPE the peak potentials were indistinguishable. This modified electrode was quite effective not only to detect AA, DA and UA, but also in simultaneous determination of each component concentration in the mixture. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
  • [1] Simultaneous Determination of Dopamine, Uric Acid and Ascorbic Acid with CTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, B. E. Kumara
    Chandra, Umesh
    Manjunatha, J. G.
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (04): : 592 - 601
  • [2] SIMULTANEOUS DETERMINATION OF ASCORBIC ACID, URIC ACID, AND DOPAMINE ON CARBON NANOTUBE PASTE ELECTRODE
    Juliao, Murilo Sergio da Silva
    Maciel, Danielle Rodrigues
    Paulino, Felipe Wesley de Vasconcelos
    Moreira, Fabriciany Lourenco
    Andrade, Lucia Betania da Silva
    dos Santos, Helcio Silva
    PERIODICO TCHE QUIMICA, 2024, 21 (47):
  • [3] Electrocatalytic oxidation and voltammetric determination of hydrazine on the tetrabromo-p-benzoquinone modified carbon paste electrode
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Ramine, Maryam
    ELECTROANALYSIS, 2007, 19 (05) : 597 - 603
  • [4] Simultaneous Determination of Dopamine, Ascorbic Acid and Uric Acid at Poly (Crystal Violet) Modified Carbon Paste Electrode
    Shankar, Sharath S.
    Swamy, Bahaddurghatta E. Kumara
    Chandra, Umesh
    Sherigara, Bailure S.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (05): : 462 - 477
  • [5] Simultaneous Determination of Dopamine, Ascorbic Acid and Uric Acid at Poly(Patton and Reeder's) Modified Carbon Paste Electrode
    Pandurangachar, M.
    Swamy, B. E. Kumara
    Chandra, Umesh
    Gilbert, Ongera
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (05): : 672 - 683
  • [6] Electrochemical behavior of chloranil chemically modified carbon paste electrode. Application to the electrocatalytic determination of ascorbic acid
    Ojani, R
    Raoof, JB
    Zamani, S
    ELECTROANALYSIS, 2005, 17 (19) : 1740 - 1745
  • [7] Simultaneous determination of dopamine, ascorbic acid and uric acid with electrospun carbon nanofibers modified electrode
    Liu, Yang
    Huang, Jianshe
    Hou, Haoqing
    You, Tianyan
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1431 - 1434
  • [8] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573
  • [9] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid, at a Graphene Paste Electrode Modified with Functionalized Graphene Sheets
    Parvin, Mohammad Hadi
    ELECTROANALYSIS, 2015, 27 (06) : 1394 - 1402
  • [10] Electrochemical determination of tryptophan, uric acid and ascorbic acid at a gold nanoparticles modified carbon paste electrode
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Saeidinejad, Faezeh
    ANALYTICAL METHODS, 2012, 4 (08) : 2447 - 2453