Simultaneous determination of inulin and p-aminohippuric acid in plasma and urine by reversed-phase high-performance liquid chromatography

被引:25
|
作者
Pastore, A
Bernardini, S
Dello Strologo, L
Rizzoni, G
Cortese, C
Federici, G
机构
[1] Childrens Hosp & Res Inst Bambino Gesu, Lab Clin Biochem, I-00165 Rome, Italy
[2] Childrens Hosp & Res Inst Bambino Gesu, Dept Nephrol & Dialysis, I-00165 Rome, Italy
[3] Univ Roma Tor Vergata, Dept Internal Med, I-00133 Rome, Italy
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 751卷 / 01期
关键词
inulin; p-Aminohippuric acid;
D O I
10.1016/S0378-4347(00)00444-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure simultaneously plasma and urine concentrations of both p-aminohippuric acid and inulin. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a C-18 reversed-phase column with a flow-rate of 1 ml/min, and monitoring the absorbance at 280 nm. Within the investigated concentration ranges of inulin (0.1-3.2 mg/ml) and p-aminohippuric acid (0.0097-0.3 mg/ml), good linearity (r>0.99) was obtained. Within-run RSD ranged from 2.9 to 6.1% and between-run RSD ranged from 6.4 to 10%. Analytical recoveries were 101-112%, with little differences between plasma and urine samples. The detection limit was 1 mug/ml for all the analytes studied. This method might be ideal for renal function studies where a rapid and reproducible assessment of both renal glomerular filtration rate and blood flow-rate is required. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [1] Simultaneous determination of inulin and p-aminohippuric acid (PAH) in human plasma and urine by high-performance liquid chromatography
    Baccard, N
    Hoizey, G
    Frances, C
    Lamiable, D
    Trenque, T
    Millart, H
    ANALYST, 1999, 124 (06) : 833 - 836
  • [2] Simultaneous determination of p-aminohippuric acid, acetyl-p-aminohippuric acid and iothalamate in human plasma and urine by high-performance liquid chromatography
    Dowling, TC
    Frye, RF
    Zemaitis, MA
    JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2): : 305 - 313
  • [3] DETERMINATION OF INULIN IN PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DALLAMICO, R
    MONTINI, G
    PISANELLO, L
    PIOVESAN, G
    BOTTARO, S
    CRACCO, AT
    ZACCHELLO, G
    ZACCHELLO, F
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (01): : 155 - 159
  • [5] Rapid determination of p-aminohippuric acid in serum and urine by high-performance liquid chromatography
    Marsilio, R
    Dall'Amico, R
    Montini, G
    Murer, L
    Ros, M
    Zacchello, G
    Zacchello, F
    JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2): : 359 - 364
  • [6] Determination of clonixin in plasma and urine by reversed-phase high-performance liquid chromatography
    Bica, A
    Farinha, A
    Blume, H
    Barbosa, CM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) : 135 - 141
  • [7] DETERMINATION OF CODEINE IN PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STUBBS, RJ
    CHIOU, R
    BAYNE, WF
    JOURNAL OF CHROMATOGRAPHY, 1986, 377 : 447 - 453
  • [8] A SEMIAUTOMATED METHOD FOR SIMULTANEOUS COLORIMETRIC DETERMINATION OF INULIN AND P-AMINOHIPPURIC ACID IN BLOOD AND URINE
    KREES, SV
    BAUKAL, AJ
    WOLFF, FW
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1967, 48 (01) : 95 - &
  • [9] EVALUATION OF SEMIAUTOMATED METHODS FOR SIMULTANEOUS DETERMINATION OF INULIN AND P-AMINOHIPPURIC ACID IN BLOOD AND URINE
    COOPER, JR
    DALE, NE
    PATHOLOGY, 1975, 7 (03) : 256 - 256
  • [10] DETERMINATION OF PEMOLINE IN PLASMA, URINE AND TISSUES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    AOYAMA, T
    KOTAKI, H
    SAITOH, Y
    NAKAGAWA, F
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (02): : 351 - 360