Functionalized screen-printed PZT cantilevers for room temperature benzene detection

被引:2
|
作者
Vazquez, R. [1 ]
Lakhmi, R. [2 ]
Debeda, H. [2 ]
Arregui, F. J. [3 ]
Zamarreno, C. R. [3 ]
Delgado, M. [4 ]
Lucat, C. [2 ]
Llobet, E. [1 ]
机构
[1] Univ Rovira & Virgili, MINOS EMaS, Tarragona, Spain
[2] Univ Bordeaux 1, Lab IMS, F-33405 Talence, France
[3] Univ Publ Navarra, IEE Dept, E-31006 Pamplona, Spain
[4] Sensotran, E-08820 Lhospitalet De Llobregat, Spain
来源
EUROSENSORS XXV | 2011年 / 25卷
关键词
microcantilever; PZT; benzene; active carbon; tin oxide; SENSORS; FILMS;
D O I
10.1016/j.proeng.2011.12.265
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Here we study the performance of screen-printed PZT cantilevers coated with either active carbon or tin oxide for room temperature detection of benzene traces. It is found that the first longitudinal mode of active carbon coated cantilevers is extremely sensitive to benzene. Shifts of -13 and -144 Hz are respectively recorded for 1 and 10 ppm of benzene. These negative shifts indicate that the response mechanism is driven by a mass absorption effect. The sensors regain the baseline values of their characteristic resonance frequencies by cleaning in air and without heating. These results are promising for the development of a hand-held benzene detector. (C) 2011 Published by Elsevier Ltd.
引用
下载
收藏
页数:4
相关论文
共 50 条
  • [1] Force Sensors Based on Screen-Printed Cantilevers
    Lakhmi, Riadh
    Debeda, Helene
    Dufour, Isabelle
    Lucat, Claude
    IEEE SENSORS JOURNAL, 2010, 10 (06) : 1133 - 1137
  • [2] Study of Screen-Printed PZT Cantilevers Both Self-Actuated and Self-Read-Out
    Lakhmi, Riadh
    Debeda, Helene
    Dufour, Isabelle
    Lucat, Claude
    Maglione, Mario
    INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2014, 11 (02) : 311 - 320
  • [3] PZT and PT screen-printed thick films
    Simon, L
    Le Dren, S
    Gonnard, P
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2001, 21 (10-11) : 1441 - 1444
  • [4] Use of the longitudinal mode of screen-printed piezoelectric cantilevers coated with PEUT for toluene detection: Comparison with silicon cantilevers
    Debeda, H.
    Lakhmi, R.
    Lucat, C.
    Dufour, I.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 187 : 198 - 203
  • [5] Electromechanical characterization of screen-printed PZT thick films
    Walter, V
    Le Moal, P
    Delobelle, P
    Joseph, E
    FIFTH EUROPEAN CONFERENCE ON SMART STRUCTURES AND MATERIALS, 2000, 4073 : 121 - 128
  • [6] Screen-Printed Gold Electrode Functionalized with Deferoxamine for Iron(III) Detection
    Alberti, Giancarla
    Zanoni, Camilla
    Rovertoni, Sara
    Magnaghi, Lisa Rita
    Biesuz, Raffaela
    CHEMOSENSORS, 2022, 10 (06)
  • [7] Direct Electrochemical Detection of Glucose on PEDOT Functionalized Screen-Printed Electrodes
    Chen, Junhao
    Nilghaz, Azadeh
    Chen, Xinyu
    Liu, Shan
    Tian, Junfei
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (08)
  • [8] An amperometric bacterial biosensor based on gold screen-printed electrodes for the detection of benzene
    Lanyon, Yvonne H.
    Tothill, Ibtisam E.
    Mascini, Marco
    ANALYTICAL LETTERS, 2006, 39 (08) : 1669 - 1681
  • [9] Flexible Screen-Printed Temperature Sensor for Active Regulation onto Screen-printed Heater
    Wawrzyniak, Maxime
    El Bourkadi, Lamiae
    Peyrard, Marion
    Rezig, Aziz
    2024 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS, FLEPS 2024, 2024,
  • [10] Electrochemical Detection of Tributyrin using Gold Nanoparticle Functionalized Screen-Printed Electrode
    Aidil, A.
    Balakrishnan, S. R.
    Zanariah, C. W.
    Ismail, W. Z. Wan
    Sahrim, M.
    Ismail, I.
    Jamaludin, J.
    19TH IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2021), 2021, : 47 - 51