The Underlying Mechanism of Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users Assessed With Objective Measure

被引:25
|
作者
Bahmer, Andreas [1 ]
Baumann, Uwe [2 ]
机构
[1] Univ Wurzburg, Comprehens Hearing Ctr, Clin Otolaryngol, Wurzburg, Germany
[2] Univ Frankfurt Main, Clin Otolaryngol, Audiol Acoust, Frankfurt, Germany
关键词
Artifact; Cochlear implant; Costimulation; Electromyography; Facial nerve stimulation; Symmetric triphasic pulses; BRAIN-STEM RESPONSES; AMPLITUDE RATIO PAR; OTOSCLEROSIS; PHASE;
D O I
10.1097/MAO.0000000000001156
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis:Triphasic pulse stimulation prevents from facial nerve stimulation (FNS) because of a different electromyographic input-output function compared with biphasic pulse stimulation.Background:FNS is sometimes observed in cochlear implant users as an unwanted side effect of electrical stimulation of the auditory nerve. The common stimulation applied in current cochlear implant consists of biphasic pulse patterns. Two common clinical remedies to prevent unpleasant FNS caused by activation of certain electrodes are to expand their pulse phase duration or simply deactivate them. Unfortunately, in some patients these methods do not provide sufficient FNS prevention. In these patients triphasic pulse can prevent from FNS. The underlying mechanism is yet unclear.Methods:Electromyographic (EMG) recordings of muscles innervated by the facial nerve (musculi orbicularis ori and oculi) were applied to quantitatively assess the effects on FNS. Triphasic and biphasic fitting maps were compared in four subjects with severe FNS. Based on the recordings, a model is presented which intends to explain the beneficial effects of triphasic pulse application.Results:Triphasic stimulation provided by fitting of an OPUS 2 speech processor device. For three patients, EMG was successfully recorded depending on stimulation level up to uncomfortable and intolerable FNS stimulation as upper boarder. The obtained EMG recordings demonstrated high individual variability. However, a difference between the input-output function for biphasic and triphasic pulse stimulation was visually observable. Compared with standard biphasic stimulation, triphasic pulses require higher stimulation levels to elicit an equal amount of FNS, as reflected by EMG amplitudes. In addition, we assume a steeper slope of the input-output function for biphasic pulse stimulation compared with triphasic pulse stimulation.Conclusion:Triphasic pulse stimulation prevents from FNS because of a smaller gradient of EMG input-output function compared with biphasic pulse stimulation. The underlying mechanism can be modeled by differences in spatiotemporal spread of the electrical field.
引用
收藏
页码:1231 / 1237
页数:7
相关论文
共 30 条
  • [1] Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users: Intraoperative Recordings
    Bahmer, Andreas
    Adel, Youssef
    Baumann, Uwe
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : E438 - E444
  • [2] Triphasic Pulses in Cochlear Implant Patients With Facial Nerve Stimulation
    Braun, Katharina
    Walker, Kevin
    Suerth, Werner
    Loewenheim, Hubert
    Tropitzsch, Anke
    OTOLOGY & NEUROTOLOGY, 2019, 40 (10) : 1268 - 1277
  • [3] Facial nerve stimulation in cochlear implant users - a matter of stimulus parameters?
    Gaertner, Lutz
    Lenarz, Thomas
    Ivanauskaite, Jurgita
    Buchner, Andreas
    COCHLEAR IMPLANTS INTERNATIONAL, 2022, 23 (03) : 165 - 172
  • [4] Hearing Performance in Cochlear Implant Users Who Have Facial Nerve Stimulation
    Rocha, Larissa Veloso
    Goffi-Gomez, Maria Valeria Schmidt
    Hoshino, Ana Cristina
    Tsuji, Robinson Koji
    Bento, Ricardo Ferreira
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2024, 28 (02) : e301 - e306
  • [5] Elimination of facial nerve stimulation by reimplantation in cochlear implant subjects
    Battmer, Rolf
    Pesch, Joerg
    Stoever, Timo
    Lesinski-Schiedat, Anke
    Lenarz, Minoo
    Lenarz, Thomas
    OTOLOGY & NEUROTOLOGY, 2006, 27 (07) : 918 - 922
  • [6] Cochlear Implant Stimulation Parameters Play a Key Role in Reducing Facial Nerve Stimulation
    Gaertner, Lutz
    Backus, Bradford C.
    Le Goff, Nicolas
    Morgenstern, Anika
    Lenarz, Thomas
    Buechner, Andreas
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
  • [7] Numerical Study of Facial Nerve Stimulation After Cochlear Implant Surgery
    Sadrach, Junaid
    van Rienen, Ursula
    PROCEEDINGS OF THE 2021 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC 2021), 2021,
  • [8] Facial nerve stimulation in adult cochlear implant recipients with far advanced otosclerosis
    Tuset, Maria-Pia
    Baptiste, Amandine
    Cyna Gorse, Francoise
    Sterkers, Olivier
    Nguyen, Yann
    Lahlou, Ghizlene
    Ferrary, Evelyne
    Mosnier, Isabelle
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (01): : 220 - 229
  • [9] Facial nerve stimulation associated with cochlear implant use following temporal bone fractures
    Espahbodi, Mana
    Sweeney, Alex D.
    Lennon, Kristen J.
    Wanna, George B.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2015, 36 (04) : 578 - 582
  • [10] Facial nerve stimulation by a cochlear implant in a hemodialysis patient with bone of low mineral density
    S. Iwasaki
    K. Atsumi
    S. Ocho
    K. Mizuta
    European Archives of Oto-Rhino-Laryngology, 1998, 255 : 352 - 354