Experimental investigation of wavelength dependence of penetration depth and imaging contrast for ultrahigh-resolution optical coherence tomography

被引:1
|
作者
Ishida, S. [1 ]
Nishizawa, N. [1 ]
Itoh, K. [2 ]
机构
[1] Nagoya Univ, Dept Elect Engn & Comp Sci, Nagoya, Aichi 4648603, Japan
[2] Osaka Univ, Div Adv Sci & Biotechnol, Suita, Osaka 5650871, Japan
关键词
optical coherence tomography; supercontinuum; optical fibers; ultrafast process in fibers; nonlinear phenomena; fiber lasers; ultrahigh resolution;
D O I
10.1117/12.874635
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical coherence tomography (OCT) is a non invasive optical imaging technology for micron-scale cross-sectional imaging of biological tissue and materials. Although OCT has many advantages in medical equipments, low penetration depth is a serious limitation for other applications. To realize the ultrahigh resolution and the high penetration depth at the same time, it is effective to choose the proper wavelength to maximize the light penetration and enhance the image contrast at deeper depths. Recently, we have demonstrated ultrahigh resolution and high penetration depth OCT by use of all-fiber based Gaussian shaped supercontinuum source at 1.7 mu m center wavelength. Gaussian-like supercontinuum with 360 nm bandwidth at center wavelength of 1.7 mu m was generated by ultrashort pulse Er doped fiber laser based system. In this paper, using 0.8 mu m and 1.3 mu m SC sources in addition to the 1.7 mu m SC source, we have investigated the wavelength dependence of ultrahigh resolution OCT in terms of penetration depth. Longitudinal resolutions at each wavelength region are almost 4.6 mu m in air. The obtained sensitivity was 95 dB for all wavelength regions. We confirmed the difference of imaging contrast and penetration depth with hamster's cheek pouch and so on. As the wavelength was increased, the magnitude of penetration depth was increased for these samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Quantitative comparison of wavelength dependence on penetration depth and imaging contrast for ultrahigh-resolution optical coherence tomography using supercontinuum sources at five wavelength regions
    Ishida, S.
    Nishizawa, N.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [2] Wavelength Dependence of Ultrahigh-Resolution Optical Coherence Tomography Using Supercontinuum for Biomedical Imaging
    Nishizawa, Norihiko
    Kawagoe, Hiroyuki
    Yamanaka, Masahito
    Matsushima, Miyoko
    Mori, Kensaku
    Kawabe, Tsutomu
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2019, 25 (01)
  • [3] Optimal wavelength for ultrahigh-resolution optical coherence tomography
    Wang, YM
    Nelson, JS
    Chen, ZP
    Reiser, BJ
    Chuck, RS
    Windeler, RS
    OPTICS EXPRESS, 2003, 11 (12): : 1411 - 1417
  • [4] Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800-1700 nm wavelength region
    Ishida, Shutaro
    Nishizawa, Norihiko
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (02): : 282 - 294
  • [5] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [6] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [7] Ultrahigh-resolution optical coherence tomography in glaucoma
    Wollstein, G
    Paunescu, LA
    Ko, TH
    Fujimoto, JG
    Kowalevicz, A
    Hartl, I
    Beaton, S
    Ishikawa, H
    Mattox, C
    Singh, O
    Duker, J
    Drexler, W
    Schuman, JS
    OPHTHALMOLOGY, 2005, 112 (02) : 229 - 237
  • [8] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [9] Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler
    Uwe Morgner
    Ravi K. Ghanta
    Franz X. Kärtner
    Joel S. Schuman
    James G. Fujimoto
    Nature Medicine, 2001, 7 : 502 - 507
  • [10] Wavelength dependence of ultrahigh resolution optical coherence tomography using supercontinuum for deep imaging
    Nishizawa, Norihiko
    Yamanaka, Masahito
    BIOMEDICAL IMAGING AND SENSING CONFERENCE 2020, 2020, 11521