Practical application issues of superconducting fault current limiters for electric power systems

被引:68
|
作者
Lee, B. W. [1 ]
Sim, J. [2 ]
Park, K. B. [2 ]
Oh, I. S. [2 ]
机构
[1] Hanyang Univ, Div Elect Engn & Comp Sci, Ansan, South Korea
[2] Electrotechnol R&D Ctr LS Ind Syst, Cheongju, South Korea
关键词
fault current; high-temperature superconductors; hybrid fault current limiters; superconducting fault current limiters;
D O I
10.1109/TASC.2008.920784
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The discovery of high-temperature superconductors were the great opportunity for developing fault current limiters using quenching phenomena. Superconducting fault current limiters is highly effective solutions to reduce and control excessive fault current which is inevitable to electric power systems. So, many companies and national research institutes were trying to develop this novel electric equipment under the assistance of national government. Due to their efforts, various types of superconducting fault current limiters were designed and tested. But, unfortunately, the practical applications and commercialization of superconducting fault current limiters are pending due to many unsolved problems. This paper discusses the current issues and commercialization problems of superconducting fault current limiters considering various aspects such as coordination with conventional relay, high voltage and high current issues, performance, cost, size, and life and maintenance issues. Then, emerging solutions for fault current limiters using hybrid method were introduced and analyzed. Finally, the viable method and our newly developed hybrid superconducting fault current limiters in order to solve the practical problems of conventional superconducting fault current limiters was briefly introduced.
引用
收藏
页码:620 / 623
页数:4
相关论文
共 50 条
  • [1] Application studies of superconducting fault current limiters in electric power systems
    Ye, L
    Lin, L
    Juengst, KP
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 900 - 903
  • [2] Applications of superconducting fault current limiters in electric power transmission systems
    Kovalsky, L
    Yuan, X
    Tekletsadik, K
    Keri, A
    Bock, J
    Breuer, F
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 2130 - 2133
  • [3] State of the art of superconducting fault current limiters and their application to the electric power system
    Morandi, Antonio
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2013, 484 : 242 - 247
  • [4] Impacts of Superconducting Fault Current Limiters on the Recloser Operation in Distribution Electric Power Systems
    Rhee, S. B.
    Lee, J. K.
    Lee, B. W.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2197 - 2200
  • [5] Fault Current Limitation Coordination in Electric Power Grid With Superconducting Fault Current Limiters
    Hayakawa, Naoki
    Maeno, Yuya
    Kojima, Hiroki
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [6] Behavior investigations of superconducting fault current limiters in power systems
    Ye, Lin
    Campbell, Archie
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 662 - 665
  • [7] Integration of Fault Current Limiters in Electric Power Systems: A Review
    Ouali, Saad
    Cherkaoui, Abdeljabbar
    IEEE SYSTEMS JOURNAL, 2021, 15 (03): : 4470 - 4479
  • [8] Behaviors and Application Prospects of Superconducting Fault Current Limiters in Power Grids
    Shu, Bin
    Li, Xue N.
    Zhang, Kai
    Sun, Xin
    Li, Wei
    Liu, Zhao Y.
    Lou, Q. H.
    Liu, Yu
    Yao, Bao Q.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (05)
  • [9] Technical and economical benefits of superconducting fault current limiters in power systems
    Universitaet Hannover, Hannover, Germany
    IEEE Trans Appl Supercond, 2 I (1347-1350):
  • [10] Technical and economical benefits of superconducting fault current limiters in power systems
    Noe, M
    Oswald, BR
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 1347 - 1350