Sinus Elevation with a Cortical Bone Graft Block: A Patient-Specific Three-Dimensional Finite Element Study

被引:1
|
作者
Schuller-Goetzburg, Peter [1 ]
Entacher, Karl [2 ]
Petutschnigg, Alexander [3 ]
Pomwenger, Werner [2 ]
Watzinger, Franz
机构
[1] Paracelsus Med Univ, A-5020 Salzburg, Austria
[2] Salzburg Univ Appl Sci, Dept Informat Technol & Syst Management, Salzburg, Austria
[3] Salzburg Univ Appl Sci, Dept Forest Prod Technol & Wood Construct, Salzburg, Austria
基金
奥地利科学基金会;
关键词
dental implant loading; finite element analysis; maxillary atrophy; sinus elevation; three-dimensional modeling; FLOOR AUGMENTATION; MAXILLARY SINUS; OSSEOINTEGRATED IMPLANTS; FOLLOW-UP; RECONSTRUCTION; 15-YEAR; FORCE;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present study was to perform a finite element (FE) analysis of a modified sinus elevation procedure involving additional implantation of a cortical bone graft block for stabilization of an implant. A secondary aim was to compare the modified sinus augmentation with the standard technique and to determine whether the FE model to replace a dental implant can be simplified into a cylinder without compromising the accuracy of the outcome. Materials and Methods: Based on computed tomography data, three-dimensional FE models of half of a maxilla were created. A basic model was generated to analyze a conventional sinus elevation procedure and another was created for the modified version, which involved insertion of a cortical bone graft block. Two implant models were used in the premolar region: a typical threaded endosseous dental implant and a simplified 4 x 10-mm cylinder. Occlusal loads were applied in axial, mediotrusive, and laterotrusive directions, and perfect bonding was assumed to be present at all interfaces. Results: The maximum von Mises stresses were significantly lower for the sinus graft models with added cortical bone than for the conventional sinus elevation under all types of loads. No significant difference was observed between the use of threaded implants and the simplified implant cylinders. Conclusion: The addition of a cortical bone graft may be a useful approach to decrease stresses around implants placed into the grafted sinus. Int J Oral Maxillofac Implants 2012;27:359-368
引用
收藏
页码:359 / 368
页数:10
相关论文
共 50 条
  • [1] Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
    Schuller-Goetzburg, Peter
    Forte, Thomas
    Pomwenger, Werner
    Petutschnigg, Alexander
    Watzinger, Franz
    Entacher, Karl
    SYMMETRY-BASEL, 2018, 10 (02):
  • [2] A method for incorporating three-dimensional residual stretches/stresses into patient-specific finite element simulations of arteries
    Pierce, David M.
    Fastl, Thomas E.
    Rodriguez-Vila, Borja
    Verbrugghe, Peter
    Fourneau, Inge
    Maleux, Geert
    Herijgers, Paul
    Gomez, Enrique J.
    Holzapfel, Gerhard A.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 47 : 147 - 164
  • [3] Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling
    Peng, Yi
    Du, Xianping
    Huang, Lihua
    Li, Jinsong
    Zhan, Ruisen
    Wang, Weiguo
    Xu, Biaoxiang
    Wu, Song
    Peng, Cheng
    Chen, Shijie
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (11) : 2137 - 2150
  • [4] Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling
    Yi Peng
    Xianping Du
    Lihua Huang
    Jinsong Li
    Ruisen Zhan
    Weiguo Wang
    Biaoxiang Xu
    Song Wu
    Cheng Peng
    Shijie Chen
    Medical & Biological Engineering & Computing, 2018, 56 : 2137 - 2150
  • [5] Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: A three-dimensional finite element analysis
    Yan, Xu
    Zhang, Xinwen
    Chi, Weichao
    Ai, Hongjun
    Wu, Lin
    ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (04) : 312 - 320
  • [6] Patient-Specific Three-Dimensional Composite Bone Models for Teaching and Operation Planning
    Felix Matthews
    Peter Messmer
    Vladislav Raikov
    Guido A. Wanner
    Augustinus L. Jacob
    Pietro Regazzoni
    Adrian Egli
    Journal of Digital Imaging, 2009, 22 : 473 - 482
  • [7] Patient-Specific Three-Dimensional Composite Bone Models for Teaching and Operation Planning
    Matthews, Felix
    Messmer, Peter
    Raikov, Vladislav
    Wanner, Guido A.
    Jacob, Augustinus L.
    Regazzoni, Pietro
    Egli, Adrian
    JOURNAL OF DIGITAL IMAGING, 2009, 22 (05) : 473 - 482
  • [8] Factors affecting stresses in cortical bone around miniscrew implants A three-dimensional finite element study
    Duaibis, Ramzi
    Kusnoto, Budi
    Natarajan, Raghu
    Zhao, Linping
    Evans, Carla
    ANGLE ORTHODONTIST, 2012, 82 (05) : 875 - 880
  • [9] Patient-specific finite element modeling for femoral bone augmentation
    Basafa, Ehsan
    Armiger, Robert S.
    Kutzer, Michael D.
    Belkoff, Stephen M.
    Mears, Simon C.
    Armand, Mehran
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (06) : 860 - 865
  • [10] A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study
    Honigmann, Philipp
    Schumacher, Ralf
    Marek, Romy
    Buttner, Franz
    Thieringer, Florian
    Haefeli, Mathias
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (04) : 407 - 412