Behavior of CVD diamond-based TL dosimeters in radiotherapy environments using photon and electron beams from treatment accelerators

被引:2
|
作者
Benabdesselam, M. [1 ]
Petitfils, A. [1 ]
Wrobel, F. [2 ]
Mady, F. [1 ]
Marcie, S. [3 ]
Gheeraert, E. [4 ,5 ]
机构
[1] Univ Nice Sophia Antipolis, Phys Mat Condensee Lab, CNRS, UMR 6622, F-06108 Nice 2, France
[2] Univ Montpellier 2, IES, F-34095 Montpellier 5, France
[3] Ctr Antoine Lacassagne, F-06189 Nice 2, France
[4] CNRS, Inst Neel, F-38042 Grenoble 9, France
[5] Univ Grenoble 1, F-38042 Grenoble 9, France
关键词
CVD diamond; Thermoluminescence; Dosimetry; Photon and electron beams; FILMS; DETECTORS;
D O I
10.1016/j.diamond.2011.02.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Chemical Vapor Deposited (CVD) diamond has great advantages for use as thermoluminescent dosimeters in radiotherapy environment because of the reproducible high quality and controlled doping. This study compares CVD diamond Thermally Stimulated Luminescence response to that of a classical ionization chamber. Clinically-relevant features like the depth-dose distributions as well as the absorbed dose profile are investigated for a 6 MV photon beam and a 6 MeV electron beam. Moreover electron beam cartography has been controlled by means of CVD diamonds. Reproducibility and repeatability of TL measurements are satisfying and a good TL sensitivity to both electron and photon beams is clearly shown. Comparing the TL responses presented here to the ionization chamber underline the very promising behavior of CVD diamonds, particularly in high dose gradient areas. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:520 / 522
页数:3
相关论文
共 4 条
  • [1] Introduction to radiotherapy with photon and electron beams and treatment planning from conformal radiotherapy to IMET
    Wilkens, Jan J.
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 63 - 69
  • [2] Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms
    Bravim, A.
    Sakuraba, R. K.
    Cruz, J. C.
    Campos, L. L.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1979 - 1981
  • [3] A TL-based anthropomorphic benchmark for verifying 3-D dose distributions from external electron beams calculated by radiotherapy treatment planning systems
    Waligorski, M. P. R.
    Baranczyk, R.
    Hyodynmaa, S.
    Eskola, J.
    Lesiak, J.
    Rozwadowska-Bogusz, B.
    Kolodziejczyk, A.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 74 - 77
  • [4] Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment
    Colnot, Julie
    Zefkili, Sofia
    Gschwind, Regine
    Huet, Christelle
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 94 - 106