Comparison of McGrath and Pentax-AWS Airwayscope for tracheal intubation by anaesthesiologists during chest compression in a manikin A randomised crossover trial

被引:12
|
作者
Komasawa, Nobuyasu [1 ]
Fujiwara, Shunsuke [1 ]
Mihara, Ryosuke [1 ]
Minami, Toshiaki [1 ]
机构
[1] Osaka Med Coll, Dept Anaesthesiol, Takatsuki, Osaka 5698686, Japan
关键词
MACINTOSH LARYNGOSCOPE; VIDEOLARYNGOSCOPE;
D O I
10.1097/EJA.0000000000000185
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:442 / 443
页数:3
相关论文
共 50 条
  • [1] Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Komasawa, Nobuyasu
    Ueki, Ryusuke
    Nomura, Hajime
    Itani, Motoi
    Kaminoh, Yoshiroh
    JOURNAL OF ANESTHESIA, 2010, 24 (02) : 306 - 308
  • [2] Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Nobuyasu Komasawa
    Ryusuke Ueki
    Hajime Nomura
    Motoi Itani
    Yoshiroh Kaminoh
    Journal of Anesthesia, 2010, 24 : 306 - 308
  • [3] Comparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial
    Fujiwara, Shunsuke
    Komasawa, Nobuyasu
    Matsunami, Sayuri
    Okada, Daisuke
    Minami, Toshiaki
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [4] COMPARISON OF HIGH AND LOW PILLOW HEIGHTS FOR TRACHEAL TUBE INTUBATION WITH THE PENTAX-AWS AIRWAYSCOPE®: A PROSPECTIVE RANDOMISED CLINICAL TRIAL
    Fujiwara, A.
    Komasawa, N.
    Kido, H.
    Kusaka, Y.
    Minami, T.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 684 - 684
  • [5] Utility of the Pentax-AWS® without interruption of chest compression: Comparison of the Macintosh laryngoscope with the Pentax-AWS® in manikin model
    Han, Sang Kuk
    Shin, Dong Hyuk
    Choi, Pil Cho
    RESUSCITATION, 2010, 81 (01) : 69 - 73
  • [6] Cricoid pressure impedes tracheal intubation with the Pentax-AWS Airwayscope®: a prospective randomized trial
    Komasawa, N.
    Kido, H.
    Miyazaki, Y.
    Tatsumi, S.
    Minami, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (03) : 413 - 416
  • [7] Comparison of Pentax-AWS® with Macintosh laryngoscope for tracheal intubation without interruption of chest compression
    Xue, F. S.
    Xiong, J.
    Wang, Q.
    Yuan, Y. J.
    Liao, X.
    RESUSCITATION, 2010, 81 (07) : 912 - 913
  • [8] Comparison of the McGrath MAC video laryngoscope and the Pentax Airwayscope during chest compression: a manikin study
    Atsushi Kotera
    Hiroki Irie
    Shinsuke Iwashita
    Junichi Taniguchi
    Shunji Kasaoka
    Yoshihiro Kinoshita
    Journal of Intensive Care, 2 (1)
  • [9] Comparison of the McGrath MAC video laryngoscope and the Pentax Airwayscope during chest compression: a manikin study
    Kotera, Atsushi
    Irie, Hiroki
    Iwashita, Shinsuke
    Taniguchi, Junichi
    Kasaoka, Shunji
    Kinoshita, Yoshihiro
    JOURNAL OF INTENSIVE CARE, 2014, 2
  • [10] Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial
    Nobuyasu Komasawa
    Ryusuke Ueki
    Noriyasu Yamamoto
    Shin-ichi Nishi
    Yoshiroh Kaminoh
    Chikara Tashiro
    Journal of Anesthesia, 2013, 27 : 778 - 780