Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes

被引:115
|
作者
He, Pingli
Shen, Li
Cao, Yunhe
Lia, Defa [1 ]
机构
[1] China Agr Univ, Natl Key Lab Anim Nutr, Beijing 100094, Peoples R China
[2] Peking Univ, Coll Chem, Beijing 100871, Peoples R China
关键词
D O I
10.1021/ac070772e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive label-free bioelectrochemical method for rapid determination of thrombin has been developed by directly detecting the redox activity of adenine (A) nucleobases of anti-thrombin aptamer using a pyrolytic graphite electrode. The bioelectrochemical protocol involves a sandwich format. Thrombin, captured by immobilzed antithrombin antibody on microtiter plates, is detected by anti-thrombin aptamer-Au nanoparticle bio bar codes. A systematic optimization of the parameters has been carried out via ELAA (enzyme linked aptamer assay) performance. The adenine nucleobases were released by acid or. nuclease from Au nanoparticles bound on microtiter plates. Differential pulse voltammetry was employed to investigate the electrochemical behaviors of the purine nucleobases. Well-defined adenine signal was observed at about 0.85 V in pH 5.9 acetate buffer. Because the nanoparticle carries a large number of aptamers per thrombin binding event, there is substantial amplification and thrombin can be detected at a very low level of detection (0.1 ng/mL). This method has been used to detect thrombin in complex matrix such as fetal calf serum with minimum background interference.
引用
收藏
页码:8024 / 8029
页数:6
相关论文
共 50 条
  • [1] Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins
    Nam, JM
    Thaxton, CS
    Mirkin, CA
    SCIENCE, 2003, 301 (5641) : 1884 - 1886
  • [2] Aptamer-Nanoparticle Assembly for Logic-Based Detection
    Shukoor, Mohammed I.
    Altman, Meghan O.
    Han, Da
    Bayrac, Abdullah Tahir
    Ocsoy, Ismail
    Zhu, Zhi
    Tan, Weihong
    ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (06) : 3007 - 3011
  • [3] Using Aptamer-Nanoparticle Conjugates for Cancer Cells Detection
    Chen, Xiaolan
    Huang, Yu-Fen
    Tan, Weihong
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2008, 4 (04) : 400 - 409
  • [4] Aptamer-Nanoparticle Strip Biosensor for Sensitive Detection of Cancer Cells
    Liu, Guodong
    Mao, Xun
    Phillips, Joseph A.
    Xu, Hui
    Tan, Weihong
    Zeng, Lingwen
    ANALYTICAL CHEMISTRY, 2009, 81 (24) : 10013 - 10018
  • [5] DNAzyme-guided polymerization of aniline for ultrasensitive electrochemical detection of nucleic acid with bio-bar codes-initiated rolling circle amplification
    Hou, Ting
    Liu, Xiaojuan
    Wang, Xiuzhong
    Jiang, Ai-wen
    Liu, Shufeng
    Li, Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 384 - 388
  • [6] Gold nanoparticle-engineered electrochemical aptamer biosensor for ultrasensitive detection of thrombin
    Chen, Ying
    Xiang, Junyi
    Liu, Bin
    Chen, Zhengbo
    Zuo, Xia
    ANALYTICAL METHODS, 2020, 12 (29) : 3729 - 3733
  • [7] Aptamer-based gold nanoparticle aggregates for ultrasensitive amplification-free detection of PSMA
    Matteoli, Giulia
    Luin, Stefano
    Bellucci, Luca
    Nifosi, Riccardo
    Beltram, Fabio
    Signore, Giovanni
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [8] Aptamer-based gold nanoparticle aggregates for ultrasensitive amplification-free detection of PSMA
    Giulia Matteoli
    Stefano Luin
    Luca Bellucci
    Riccardo Nifosì
    Fabio Beltram
    Giovanni Signore
    Scientific Reports, 13 (1)
  • [9] Ultrasensitive aptamer-based bio bar code immunomagnetic separation and electrochemiluminescence method for the detection of protein
    Zhu, Debin
    Hou, Xiaoming
    Xing, Da
    ANALYTICA CHIMICA ACTA, 2012, 725 : 39 - 43
  • [10] Multianalyte Electrochemical Biosensor Based on Aptamer- and Nanoparticle-Integrated Bio-Barcode Amplification
    Li, Xuemei
    Xia, Jianping
    Li, Wei
    Zhang, Shusheng
    CHEMISTRY-AN ASIAN JOURNAL, 2010, 5 (02) : 294 - 300