Equivalent static wind loads on low-rise buildings based on full-scale pressure measurements

被引:33
|
作者
Chen, Xinzhong [1 ]
Zhou, Nan
机构
[1] Texas Tech Univ, Dept Civil & Environm Engn, Wind Sci & Engn Res Ctr, Lubbock, TX 79409 USA
[2] Valmont Wind Energy Inc, Valley, NE 68064 USA
关键词
building; low-rise; wind load; wind; building code; full-scale pressure measurement;
D O I
10.1016/j.engstruct.2007.01.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper addresses the modeling of equivalent static wind loads (ESWLs) on low-rise buildings based on full-scale pressure measurements. The wind load effects of different building frames under alongwind excitations are quantified and compared with those based on the wind loads specified in ASCE 7-05 to examine the adequacy of current design wind load. The ESWLs causing different peak wind load effects of building frames are investigated using a number of approaches, which include the gust response factor (GRF), gust loading envelope (GLE) and load-response-correlation (LRC) approaches. This investigation points out the challenges faced in seeking advanced ESWLs on low-rise buildings which are physically meaningful and insensitive to individual response. Finally, a new approach for modeling ESWLs based on the proper orthogonal decomposition of wind loading field is proposed. The new approach provides a set of ESWLs associated with a small number of important loading modes which are independent of individual response and structural systems, and is able to give accurate prediction of all responses. The proposed approach offers a physically meaningful and convenient modeling of wind loads on low-rise buildings with great potential of design applications. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2563 / 2575
页数:13
相关论文
共 50 条