Systematic Scoring Balloon Lesion Preparation for Drug-Coated Balloon Angioplasty in Clinical Routine: Results of the PASSWORD Observational Study

被引:28
|
作者
Bonaventura, Klaus [1 ]
Schwefer, Markus [2 ]
Yusof, Ahmad Khairuddin Mohamed [3 ]
Waliszewski, Matthias [4 ,5 ]
Krackhardt, Florian [5 ]
Steen, Philip [1 ,4 ]
Ocaranza, Raymundo [6 ]
Zuhdi, Ahmad Syadi [7 ]
Bang, Liew Houng [8 ]
Graf, Kristof [9 ]
Boeck, Ulrich [10 ]
Chin, Kenneth [11 ]
机构
[1] Klinikum Ernst von Bergmann, Potsdam, Germany
[2] Elblandklinikum Riesa, Riesa, Germany
[3] Natl Heart Inst Malaysia, Kuala Lumpur, Malaysia
[4] B Braun Melsungen AG, Med Sci Affairs, Berlin, Germany
[5] Charite Univ Med Berlin, Dept Cardiol & Internal Med, Campus Virchow, Berlin, Germany
[6] Hosp Univ Lucus Augusti, Lugo, Spain
[7] Pusat Perubatan Univ Malaya, Kuala Lumpur, Malaysia
[8] Hosp Queen Elizabeth II, Kota Kinabalu, Sabah, Malaysia
[9] Jud Krankenhaus Berlin, Berlin, Germany
[10] Marien Hosp Marl, Marl, Germany
[11] Pantai Hosp Kuala Lumpur, Kuala Lumpur, Malaysia
关键词
De novo lesion; Drug-coated balloon; Lesion preparation; Scoring balloon; Stent-less intervention; Target lesion failure; PACLITAXEL-ELUTING STENT; INTRAVASCULAR ULTRASOUND; PLAQUE MODIFICATION; CORONARY PLAQUE; MULTICENTER; RESTENOSIS;
D O I
10.1007/s12325-020-01320-2
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction Scoring balloon angioplasty (SBA) for lumen gain prior to stent implantations or drug-coated balloon angioplasty (DCB) is considered an essential interventional tool for lesion preparation. Recent evidence indicates that SBA may play a pivotal role in enhancing the angiographic and clinical outcomes of DCB angioplasty. Methods We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292). Results A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 +/- 10.4 mm in the de novo group, and 20.1 +/- 8.9 mm (BMS-ISR) and 16.2 +/- 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 +/- 0.41 mm (de novo), 2.71 +/- 0.31 mm (BMS-ISR), and 2.92 +/- 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 +/- 0.39 mm (de novo), 3.00 +/- 0.35 mm (BMS-ISR), and 3.10 +/- 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901). Conclusions The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.
引用
收藏
页码:2210 / 2223
页数:14
相关论文
共 50 条
  • [1] Systematic Scoring Balloon Lesion Preparation for Drug-Coated Balloon Angioplasty in Clinical Routine: Results of the PASSWORD Observational Study
    Klaus Bonaventura
    Markus Schwefer
    Ahmad Khairuddin Mohamed Yusof
    Matthias Waliszewski
    Florian Krackhardt
    Philip Steen
    Raymundo Ocaranza
    Ahmad Syadi Zuhdi
    Liew Houng Bang
    Kristof Graf
    Ulrich Böck
    Kenneth Chin
    Advances in Therapy, 2020, 37 : 2210 - 2223
  • [2] Impact of Chocolate percutaneous transluminal angioplasty balloon on vessel preparation in drug-coated balloon angioplasty for femoropopliteal lesion
    Shigemitsu Shirai
    Shinsuke Mori
    Kohei Yamaguchi
    Masafumi Mizusawa
    Toshiki Chishiki
    Kenji Makino
    Yohsuke Honda
    Masakazu Tsutsumi
    Mana Hiraishi
    Norihiro Kobayashi
    Masahiro Yamawaki
    Yoshiaki Ito
    CVIR Endovascular, 5
  • [3] Impact of Chocolate percutaneous transluminal angioplasty balloon on vessel preparation in drug-coated balloon angioplasty for femoropopliteal lesion
    Shirai, Shigemitsu
    Mori, Shinsuke
    Yamaguchi, Kohei
    Mizusawa, Masafumi
    Chishiki, Toshiki
    Makino, Kenji
    Honda, Yohsuke
    Tsutsumi, Masakazu
    Hiraishi, Mana
    Kobayashi, Norihiro
    Yamawaki, Masahiro
    Ito, Yoshiaki
    CVIR ENDOVASCULAR, 2022, 5 (01)
  • [4] Drug-coated balloon superior to standard balloon angioplasty
    Karina Huynh
    Nature Reviews Cardiology, 2017, 14 : 383 - 383
  • [5] Drug-Coated Balloon "Scoring to Win"
    de la Torre Hernandez, Jose M.
    Puri, Rishi
    Alfonso, Fernando
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (13) : 1341 - 1343
  • [6] Arterial Preparation Improves Outcomes of Drug-Coated Balloon Angioplasty
    Hayoz, Daniel
    Engelberger, Rolf
    Periard, Daniel
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E162 - E162
  • [7] Upfront scoring balloon predilatation in treatment of de-novo lesions with drug-coated balloon angioplasty
    Rajagopal, Rajinikanth
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2024, 72 (03) : 305 - 306
  • [8] TO CUT OR NOT TO CUT: CUTTING BALLOON FOR LESION PREPARATION BEFORE DRUG COATED BALLOON ANGIOPLASTY
    Facci, G.
    Bottardi, A.
    Venturi, G.
    Mugnolo, A.
    Zamboni, A.
    Bacchion, F.
    Morando, G.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2024, 26 : ii45 - ii45
  • [9] Lesion Preparation With Scoring Balloon Improves the Efficacy of Drug-Coated Balloon Treatment in Patients With De Novo Coronary Artery Disease
    Ge, Zhen
    Chen, Shao-Liang
    Zhang, Junjie
    Gao, Xiaofei
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B136 - B136
  • [10] Is intravascular ultrasound needed to optimize drug-coated balloon angioplasty results?
    Alfonso, Fernando
    Cortese, Bernardo
    EUROPEAN HEART JOURNAL, 2024, 45 (42) : 4542 - 4543