Determination of the Isotopic Composition of an Enriched Hafnium Spike by MC-ICP-MS Using a Regression Model

被引:4
|
作者
Lin, Ran [1 ,2 ]
Lin, Jie [1 ]
Zong, Keqing [1 ,2 ]
Chen, Kang [1 ]
Tong, Shuoyun [1 ]
Feng, Lanping [1 ]
Zhang, Wen [1 ]
Li, Ming [1 ]
Liu, Yongsheng [1 ,2 ]
Hu, Zhaochu [1 ]
Zhou, Lian [1 ]
机构
[1] China Univ Geosci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[2] China Univ Geosci, Sch Earth Sci, Wuhan 430074, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Hf isotopic composition; enriched spike; isotope dilution; regression model; MASS BIAS CORRECTION; LU-HF; SM-ND; DILUTION ANALYSES; GARNET GEOCHRONOLOGY; PRECISE; RATIO; PB; CLOSURE; ZR;
D O I
10.1111/ggr.12343
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The isotope dilution (ID) method, owing to its high precision, is extensively used for the determination of element mass fractions in a wide range of natural samples. One of the prerequisites of the ID method is knowledge of the isotopic composition of an enriched spike, which is often challenging to accurately determine. In this study, we employ a regression mass bias correction model to accurately and precisely measure the isotopic composition of an enriched Hf spike (Lot No. 159293, Oak Ridge National Laboratory). A NIST SRM 3134 Re solution, whose isotopic composition was calibrated by an NRC IRIS-1 Ir isotope standard, was used to calibrate the isotopic composition of the Hf spike. The obtained ratios of(176)Hf/Hf-177,Hf-179/Hf-177 and(180)Hf/Hf-177 were 0.2406 +/- 0.0005 (u, k = 1), 2.8620 +/- 0.0005 (u, k = 1) and 384.65 +/- 0.05 (u, k = 1), respectively, which meet the required precision levels for Hf isotopes in the application of the ID method. The combined uncertainties of the calibrated Re and Hf isotope ratios were evaluated using a Monte Carlo method, in which the uncertainty of the primary calibrator (IRIS-1,Ir-193/Ir-191 = 1.6866 +/- 0.0005,u,k = 1) was also taken into consideration. The precision of Hf spike was improved significantly compared with the SSB and C-SSBIN methods. To the best of our knowledge, this is the first report of isotope ratio calibration in an enriched spike using the regression model. The precisely calibrated spike can lower the uncertainty of the Hf mass fraction significantly, thereby increasing the accuracy of the Lu-Hf chronometer.
引用
收藏
页码:753 / 762
页数:10
相关论文
共 50 条
  • [1] Determination of the Isotopic Composition of an Enriched Lutetium Spike by MC-ICP-MS
    Lin, Ran
    Zong, Keqing
    Lin, Jie
    Yang, Ao
    Chen, Kang
    Hu, Zhaochu
    Liu, Yongsheng
    ATOMIC SPECTROSCOPY, 2022, 43 (05) : 396 - 402
  • [2] Determination of the Isotopic Composition of Ytterbium by MC-ICP-MS Using an Optimized Regression Model
    Lin, Ran
    Lin, Jie
    Zong, Keqing
    Yang, Ao
    Chen, Kang
    Liu, Yongsheng
    Hu, Zhaochu
    ANALYTICAL CHEMISTRY, 2022, 94 (20) : 7200 - 7209
  • [3] Determination of the isotopic composition of tungsten using MC-ICP-MS
    Zhang, Rouxi
    Meija, Juris
    Huang, Yi
    Pei, Xiangjun
    Mester, Zoltan
    Yang, Lu
    ANALYTICA CHIMICA ACTA, 2019, 1089 : 19 - 24
  • [4] Precise determination of the isotopic composition of Sn using MC-ICP-MS
    Clayton, R
    Andersson, P
    Gale, NH
    Gillis, C
    Whitehouse, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1248 - 1256
  • [5] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828
  • [6] Precise Analysis of Gallium Isotopic Composition by MC-ICP-MS
    Yuan, Wei
    Chen, Jiu Bin
    Birck, Jean-Louis
    Yin, Zuo Ying
    Yuan, Sheng Liu
    Cai, Hong Ming
    Wang, Zhong Wei
    Huang, Qiang
    Wang, Zhu Hong
    ANALYTICAL CHEMISTRY, 2016, 88 (19) : 9606 - 9613
  • [7] Determination of the zirconium isotopic composition of the new isotopic standard NRC ZIRC-1 using MC-ICP-MS
    Tian, Shengyu
    Moynier, Frederic
    Inglis, Edward C.
    Jensen, Ninna K.
    Deng, Zhengbin
    Schiller, Martin
    Bizzarro, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (03) : 656 - 662
  • [8] Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W
    Wang, Zhao-Yang
    Dong, Fei-Yu
    Yin, Lu
    Liu, Jun-Jie
    Zhong, Qiao-Hui
    Li, Jie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (10) : 2443 - 2451
  • [9] Determination of Nd isotopic composition in seawater using newly developed solid phase extraction and MC-ICP-MS
    Tazoe, Hirofumi
    Amakawa, Hiroshi
    Suzuki, Katsuhiko
    Nishioka, Jun
    Hara, Takuya
    Obata, Hajime
    TALANTA, 2021, 232
  • [10] Determination of lead isotopic ratios in ferromanganese crust by using MC-ICP-MS and NanoSIMS
    Takata, Y.
    Tanimzu, A.
    Takahata, N.
    Amakawa, H.
    Sano, Y.