Optimisation and routine use of generic ultra-high flow-rate liquid chromatography with mass spectrometric detection for the direct on-line analysis of pharmaceuticals in plasma

被引:66
|
作者
Ayrton, J [1 ]
Dear, GJ [1 ]
Leavens, WJ [1 ]
Mallett, DN [1 ]
Plumb, RS [1 ]
机构
[1] GlaxoWellcome Res & Dev, Int Dev, Bioanal & Drug Metab Div, Ware SG12 0DP, Herts, England
关键词
ultra-high flow-rate liquid chromatography; flow-rate; pharmaceutical analysis; isoquinolines;
D O I
10.1016/S0021-9673(98)00579-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of ultra-high flow-rate chromatography coupled to mass spectrometry offers great potential for the rapid, on-line analysis of pharmaceutical compounds in plasma as it permits high throughput direct analysis of plasma samples without any time-consuming sample preparation such as solid-phase extraction. The coupling of mass spectrometry with high performance liquid chromatography often results in enhanced selectivity and sensitivity compared to, for example, ultraviolet absorbance detection. This can remove the need for complete resolution of the analyte from endogenous materials in the matrix. The use of large particle size stationary phases, and therefore, the ability to use large porosity column end frits, coupled with the added selectivity and sensitivity of the mass spectrometer allows an on-line analysis approach to be used for the direct analysis of pharmaceuticals in biological matrices with extremely high throughput. This paper presents an overview of the manner in which we have optimised this technique for the analysis of plasma samples, in terms of gradient profile, system configuration and optimal injection volume for maximum throughput and robustness. The nature of the mobile phase flow is also discussed. (C) 1998 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 50 条
  • [1] Ultra-high flow rate capillary liquid chromatography with mass spectrometric detection for the direct analysis of pharmaceuticals in plasma at sub-nanogram per millilitre concentrations
    Ayrton, J
    Clare, RA
    Dear, GJ
    Mallett, DN
    Plumb, RS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (16) : 1657 - 1662
  • [2] Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughput
    Bayliss, MK
    Little, D
    Mallett, DN
    Plumb, RS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (21) : 2039 - 2045
  • [3] An automated method for measurement of methoxetamine in human plasma by use of turbulent flow on-line extraction coupled with liquid chromatography and mass spectrometric detection
    Emuri Abe
    Florian Ricard
    François Darrouzain
    Jean Claude Alvarez
    Analytical and Bioanalytical Chemistry, 2013, 405 : 239 - 245
  • [4] An automated method for measurement of methoxetamine in human plasma by use of turbulent flow on-line extraction coupled with liquid chromatography and mass spectrometric detection
    Abe, Emuri
    Ricard, Florian
    Darrouzain, Francois
    Alvarez, Jean Claude
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 239 - 245
  • [5] Direct analysis of a polar pharmaceutical compound in plasma using ultra-high flow rate liquid chromatography/mass spectrometry with a mixed-mode column
    Mallett, DN
    Dear, GJ
    Plumb, RS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) : 2526 - 2529
  • [6] The use of ultra-high pressure liquid chromatography with tandem mass spectrometric detection in the analysis of agrochemical residues and mycotoxins in food - Challenges and applications
    O'Mahony, John
    Clarke, Lesa
    Whelan, Michelle
    O'Kennedy, Richard
    Lehotay, Steven J.
    Danaher, Martin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1292 : 83 - 95
  • [7] Generic Methods for Simultaneous Analysis of Four Direct Oral Anticoagulants in Human Plasma and Urine by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ren, Jian-Wei
    Zheng, Xin
    Han, Xiao-Hong
    MOLECULES, 2023, 28 (05):
  • [8] Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry
    Grant, RP
    Cameron, C
    Mackenzie-McMurter, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) : 1785 - 1792
  • [9] Determination of Acequinocyl and Hydroxyacequinocyl Residues in Food by Ultra-High Performance Liquid Chromatography Separation and Tandem Mass Spectrometric Detection
    Ying, Xiaohong
    Cheng, Heyong
    Hao, Xin
    Gao, Haibo
    Zhang, Mengmeng
    Wu, Lili
    Wang, Haijian
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 578 - 585
  • [10] Determination of Acequinocyl and Hydroxyacequinocyl Residues in Food by Ultra-High Performance Liquid Chromatography Separation and Tandem Mass Spectrometric Detection
    Xiaohong Ying
    Heyong Cheng
    Xin Hao
    Haibo Gao
    Mengmeng Zhang
    Lili Wu
    Haijian Wang
    Food Analytical Methods, 2015, 8 : 578 - 585