Study on the Simultaneous Measurement of O2 and CO Concentrations in the Exhaust Gas of a Methane/Air Flame Using Tunable Diode Laser Absorption Spectroscopy

被引:9
|
作者
So, Sunghyun [1 ,2 ]
Park, Dae Gun [1 ]
Jeong, Nakwon [1 ,2 ]
Kim, Daehae [1 ]
Hwang, Jungho [2 ]
Lee, Changyeop [1 ]
机构
[1] Korea Inst Ind Technol, Thermochem Energy Syst R&BD Grp, Cheonan 31056, South Korea
[2] Yonsei Univ, Mech Engn Dept, Seoul 03722, South Korea
关键词
WAVELENGTH-MODULATION-SPECTROSCOPY; TEMPERATURE; SENSOR; H2O; NM;
D O I
10.1021/acs.energyfuels.9b04357
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Oxygen (O-2) and carbon monoxide (CO) are produced in combustion reactions and are important gas species, which are closely related to combustion efficiency and production of air pollutants. O-2 generates thermal nitrogen oxide (NOx) by reacting with nitrogen in the air at high temperatures, and the presence of excess O-2 also affects the energy efficiency as a result of increasing exhaust heat energy. CO is generally well-known for being a toxic gas and is a crucial gas species produced by incomplete combustion. However, it is difficult to measure O-2 and CO level variations in a huge combustion system, such as used in steel annealing and power plant boilers, because of their harsh environment. Therefore, as a multi-species measurement technique, which is non-intrusive and has a high sensitivity and high response, tunable diode laser absorption spectroscopy was chosen as the optical method used to measure O-2 and CO concentrations in exhaust gases. In this study, experiments were carried out to measure the O-2 and CO concentrations in an electrical furnace and a combustion system using direct absorption spectroscopy and wavelength modulation spectroscopy. The measured results were compared to those of a gas analyzer of the electrochemical sensor type. The O-2 and CO concentrations were measured in the exhaust gas produced from methane/air flame through adjustment of the equivalence ratio to form both fuel-lean and fuel-rich conditions. To measure the O-2 and CO concentrations precisely and without interference from other combustion products, visible and near-infrared wavelength regions at 760.8 and 2325.2 nm were selected, respectively.
引用
收藏
页码:3780 / 3787
页数:8
相关论文
共 50 条
  • [1] Detection Limit of CO Concentration Measurement in LPG/Air Flame Flue Gas Using Tunable Diode Laser Absorption Spectroscopy
    So, Sunghyun
    Park, Jiyeon
    Song, Aran
    Hwang, Jungho
    Yoo, Miyeon
    Lee, Changyeop
    ENERGIES, 2020, 13 (16)
  • [2] CO CONCENTRATION MEASUREMENT IN THE HIGH TEMPERATURE FLAME WITH TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
    Xu, Ting
    Wang, Fei
    Jiang, Zhishen
    Yan, Jianhua
    Cen, Kefa
    Yuan, Ke
    Xiao, Huiping
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 271 - +
  • [3] Tunable diode laser absorption spectroscopy for simultaneous measurement of ethylene and methane near 1.626 μm
    Pan Wei-Dong
    Zhang Jia-Wei
    Dai Jing-Min
    Zhang Yu-Feng
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2013, 32 (06) : 486 - 490
  • [4] The use of tunable diode laser absorption spectroscopy for the measurement of flame dynamics
    Hendricks, AG
    Vandsburger, U
    Saunders, WR
    Baumann, WT
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (01) : 139 - 144
  • [5] Transient gas viscosity measurement using tunable diode laser absorption spectroscopy
    Rongkang Gao
    Sean O’Byrne
    Suzanne L. Sheehe
    Joseph Kurtz
    Jong-Leng Liow
    Experiments in Fluids, 2017, 58
  • [6] Transient gas viscosity measurement using tunable diode laser absorption spectroscopy
    Gao, Rongkang
    O'Byrne, Sean
    Sheehe, Suzanne L.
    Kurtz, Joseph
    Liow, Jong-Leng
    EXPERIMENTS IN FLUIDS, 2017, 58 (11)
  • [7] Automotive exhaust gas analysis by infrared tunable diode laser absorption spectroscopy
    Louvet, Y
    deBorniol, E
    Henry, D
    Mohamed, A
    Rosier, B
    Jones, W
    COMBUSTION DIAGNOSTICS, 1997, 3108 : 54 - 62
  • [8] Simultaneous In-Situ Measurement of Soot Volume Fraction, H2O Concentration, and Temperature in an Ethylene/Air Premixed Flame Using Tunable Diode Laser Absorption Spectroscopy
    Wu, Qi
    Wang, Fei
    Li, Meiyi
    Yan, Jianhua
    Cen, Kefa
    COMBUSTION SCIENCE AND TECHNOLOGY, 2017, 189 (09) : 1571 - 1590
  • [9] Improvement of combustion control through real-time measurement of O2 and CO concentrations in incinerators using diode laser absorption spectroscopy
    Deguchi, Y
    Noda, M
    Abe, M
    Abe, M
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2002, 29 : 147 - 153
  • [10] Study on CO2 Measurement Using Tunable Multi-Mode Diode Laser Absorption Spectroscopy
    Gao Guang-zhen
    Chen Bao-xue
    Hu Bo
    Long Xiu-hui
    Li Ai-ping
    Li Rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (12) : 3269 - 3272