Evaluation of a Novel Contactless Electrical Impedance Device for Measuring Respiratory and Heart Rates: A Pilot Study

被引:0
|
作者
Iwashita, Yoshiaki [1 ]
Nebuya, Satoru [2 ]
机构
[1] Shimane Univ, Dept Emergency & Crit Care Med, Izumo, Japan
[2] Shimane Univ, Collaborat Res Programs Adv Med Elect Engn, Izumo, Japan
关键词
vital signs monitor; mechanical ventilation; medical engineering; heart rate; respiratory rate; electrical impedance tomography; ARREST;
D O I
10.7759/cureus.18622
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the respiratory rate is an important vital sign, it is rarely recorded in hospitals given the lack of convenient measurement devices. Posh Wellness Laboratory Inc. (Tokyo, Japan) developed a novel contactless card-type respiratory/heart rate monitoring device that measures electrical impedance variations on the human chest. This study was aimed to test and validate the accuracy of the proposed device compared with conventional medical monitors. To evaluate the card-type monitoring device, we compared the measurements from the device with those from the mechanical ventilators and electrocardiogram monitors. Patients who were hospitalized in the Emergency Department of Shimane University Hospital from April 5 to 30, 2021 were included in this study. A card-type sensor was attached to five patients who agreed to participate in this study. Four of the five patients were receiving mechanical ventilation. The respiratory rate error provided by the card-type sensor remained within 15% compared with the measurements of the conventional medical monitor. In contrast, the heart rate counts were largely different from the measurements. Thus, the proposed device can successfully measure the respiratory rate, whereas heart rate measurements require further improvement. Our small, lightweight, radiation-free, and contactless monitoring device can conveniently measure the respiratory rate of patients. With the improvement of measuring the heart rate, we would like to assess a larger number and a wider range of patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Realization and Evaluation of the Device for Measuring the Impedance of Human Body for Detecting the Respiratory and Heart Rate
    Metshein, Margus
    Parve, Toomas
    Annus, Paul
    Rist, Marek
    Min, Mart
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2017, 23 (03) : 36 - 42
  • [2] A DEVICE FOR MEASURING THE MEAN ELECTRICAL AXIS OF THE HEART
    TOPP, JH
    ROSENBAUM, FF
    [J]. AMERICAN HEART JOURNAL, 1949, 38 (01) : 130 - 134
  • [3] A novel method for the quantitative evaluation of diurnal respiratory instability in patients with heart failure: A pilot study
    Kumagai, Naoto
    Dohi, Kaoru
    Fujimoto, Naoki
    Tanimura, Muneyoshi
    Sato, Yuichi
    Miyahara, So
    Nakamori, Shiro
    Fujii, Eitaro
    Yamada, Norikazu
    Ito, Masaaki
    [J]. JOURNAL OF CARDIOLOGY, 2018, 71 (1-2) : 159 - 167
  • [4] Quantification of Water Loss with a Portable Bio-electrical Impedance Device in Patients with Acute Decompensated Heart Failure: A Pilot Study
    Velazquez-Cecena, Jose-Luis E.
    Moningi, Srikanth
    Adigopula, Sasikanth
    Nagajothi, Nagapradeep
    Khosla, Sandeep
    [J]. CIRCULATION, 2008, 118 (18) : S614 - S615
  • [5] Contactless electrical impedance and ultrasonic tomography: correlation, comparison and complementarity study
    Jiang, Yandan
    Soleimani, Manuchehr
    Wang, Baoliang
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (11)
  • [6] Development and Evaluation of a Contactless Heart Rate Measurement Device Based on rPPG
    Ahmadi, Nur
    Al Farisyi, M. Salman
    Prihatmoko, M. Dzaky
    Hyanda, M. Heronan
    Muhaimin, Habibur
    Mulyawan, Rahmat
    Charlton, Peter H.
    Adiono, Trio
    [J]. 2022 29TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (IEEE ICECS 2022), 2022,
  • [7] A NOVEL DEVICE FOR MEASURING MECHANICAL IMPEDANCE DURING DYNAMIC TASKS
    Hondori, Hossein Mousavi
    Ling Shih-Fu
    [J]. BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2010, : 64 - 68
  • [8] Electrical impedance measurements on teeth using the ECM-device -: a comparative in vivo and in vitro pilot study
    Tranæus, S
    Ollmar, S
    Lussi, A
    Angmar-Månsson, B
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1247 - 1247
  • [9] Magnetic Resonance Electrical Impedance Mammography: A pilot study
    Kallergi, Maria
    Wollin, Ernest
    Heine, John J.
    Kovalchuk, Nataliya
    Manohar, Anand
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 468 - 474
  • [10] Measuring respiratory and heart rate using a fiber optic interferometer: A pilot study in a neonate model
    Cubik, Jakub
    Kepak, Stanislav
    Wiedermannova, Hana
    Vrtkova, Adela
    Burckova, Hana
    Zarubova, Pavla
    Fernandez, Carlos
    Pavlicek, Jan
    Jargus, Jan
    Vasinek, Vladimir
    [J]. FRONTIERS IN PEDIATRICS, 2022, 10