Portable electrochemical system using screen-printed electrodes for monitoring corrosion inhibitors

被引:14
|
作者
Squissato, Andre L. [1 ]
Silva, Weberson P. [1 ]
Del Claro, Augusto T. S. [1 ]
Rocha, Diego P. [1 ]
Dornellas, Rafael M. [1 ]
Richter, Eduardo M. [1 ]
Foster, Christopher W. [2 ]
Banks, Craig E. [2 ]
Munoz, Rodrigo A. A. [1 ]
机构
[1] Univ Fed Uberlandia, Chem Inst, BR-38400902 Uberlandia, MG, Brazil
[2] Manchester Metropolitan Univ, Fac Sci & Environm, Manchester M1 5GD, Lancs, England
关键词
Amperometry; Anticorrosive; Batch-injection analysis; Fuel; Oil; Seawater; BATCH-INJECTION-ANALYSIS; PULSED-AMPEROMETRIC DETECTION; PHARMACEUTICAL FORMULATIONS; 2,5-DIMERCAPTO-1,3,4-THIADIAZOLE; COPPER; BIODIESEL; INDUSTRIAL; FUELS; STEEL; LEAD;
D O I
10.1016/j.talanta.2017.06.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a portable electrochemical system for the continuous monitoring of corrosion inhibitors in a wide range of matrices including ethanol, seawater and mineral oil following simple dilution of the samples. Proof-of-concept is demonstrated for the sensing of 2,5-dimercapto-1,3,5-thiadiazole (DMCT), an important corrosion inhibitor. Disposable screen-printed graphitic electrodes (SPGEs) associated with a portable batch-injection cell are proposed for the amperometric determination of DMCT following sample dilution with electrolyte (95% v/v ethanol + 5% v/v 0.1 mol L-1 H2SO4 solution). This electrolyte was compatible with all samples and the organic-resistant SPGE could be used continuously for more than 200 injections (100 mu L injected at 193 mu L s(-1)) free from effects of adsorption of DMCT, which have a great affinity for metallic surfaces, and dissolution of the other reported SPGE inks which has hampered prior research efforts. Fast (180h(-1)) and precise responses (RSD < 3% n = 10) with a detection limit of 0.3 mu mol L-1 was obtained. The accuracy of the proposed method was attested through recovery tests (93-106%) and the reasonable agreement of results of DMCT concentrations in samples analyzed by both proposed and spectrophotometric (comparative) methods.
引用
下载
收藏
页码:420 / 427
页数:8
相关论文
共 50 条
  • [1] Electrochemical determination of propranolol by using modified screen-printed electrodes
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Beitollahi, Hadi
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2020, 27 (01) : 73 - 78
  • [2] Electrochemical determination of antihypertensive drugs by employing costless and portable unmodified screen-printed electrodes
    Khorshed, Ahmed A.
    Khairy, Mohamed
    Banks, Craig E.
    TALANTA, 2019, 198 : 447 - 456
  • [3] DISPOSABLE SCREEN-PRINTED ELECTRODES FOR MONITORING HYDRAZINES
    WANG, J
    PAMIDI, PVA
    TALANTA, 1995, 42 (03) : 463 - 467
  • [4] Screen-printed electrochemical chromium (VI) sensing electrodes for effluent bioremediation monitoring
    Maeder, T.
    Miscoria, S.
    Jacq, C.
    Ryser, P.
    Martin Negri, R.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1303 - 1306
  • [5] Beer discrimination using a portable electronic tongue based on screen-printed electrodes
    Blanco, Carlos A.
    de la Fuente, Rocio
    Caballero, Isabel
    Rodriguez-Mendez, Maria L.
    JOURNAL OF FOOD ENGINEERING, 2015, 157 : 57 - 62
  • [6] Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes
    Perez-Fernandez, Beatriz
    Costa-Garcia, Agustin
    de la Escosura-Muniz, Alfredo
    BIOSENSORS-BASEL, 2020, 10 (04):
  • [7] Electrochemical determination of bentazone using simple screen-printed carbon electrodes
    Geto, Alemnew
    Noori, Jafar Safaa
    Mortensen, John
    Svendsen, Winnie E.
    Dimaki, Maria
    ENVIRONMENT INTERNATIONAL, 2019, 129 : 400 - 407
  • [8] Screen-printed electrodes
    Nascimento, VB
    Angnes, L
    QUIMICA NOVA, 1998, 21 (05): : 614 - 629
  • [9] Screen-printed atmospheric corrosion monitoring sensor based on electrochemical impedance spectroscopy
    Shitanda, Isao
    Okumura, Ayaka
    Itagaki, Masayuki
    Watanabe, Kunihiro
    Asano, Yasufumi
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (02) : 292 - 297
  • [10] Screen-printed electrodes as versatile electrochemical sensors and biosensors
    Cinti, Stefano
    Moscone, Danila
    Arduini, Fabiana
    2017 IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS), 2017,