In Vitro ADME Profiling Using High-Throughput RapidFire Mass Spectrometry: Cytochrome P450 Inhibition and Metabolic Stability Assays

被引:48
|
作者
Wu, Xiang [1 ]
Wang, Jing [1 ]
Tan, Lory [1 ]
Bui, John [1 ]
Gjerstad, Erik [1 ]
McMillan, Kirk [1 ]
Zhang, Wentao [1 ]
机构
[1] Exelixis Inc, New Lead Discovery, San Francisco, CA 94083 USA
关键词
in vitro ADME; drug-drug interactions; metabolic stability; CYP450; lead profiling; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN LIVER-MICROSOMES; DRUG-INTERACTIONS; POINT IC50; COCKTAIL; VALIDATION; ENZYMES; CYP3A4; TESTOSTERONE; FLUORESCENCE;
D O I
10.1177/1087057112441013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Early assessment of absorption, distribution, metabolism, and excretion (ADME) properties of drug candidates has become an essential component of modern drug discovery. ADME characterization is important in identifying compounds early that are likely to fail in later clinical development because of suboptimal pharmacokinetic properties or undesirable drug-drug interactions. Proper utilization of ADME results, meanwhile, can prioritize candidates that are more likely to have good pharmacokinetic properties and also minimize potential drug-drug interactions. By integrating a RapidFire system with an API4000 mass spectrometer (RF-MS), we have established a high-throughput capability to profile compounds (> 100 compounds/wk) in a panel of ADME assays in parallel with biochemical and cellular characterizations. Cytochrome P450 inhibition and time-dependent inhibition assays and microsomal stability assays were developed and fully optimized on the system. Compared with the classic liquid chromatography-mass spectrometry method, the RF-MS system generates consistent data with approximately 20-fold increase in throughput. The lack of chromatographic separation of compounds, substrates, and metabolites can complicate data interpretation, but this occurs in a small number of cases that are readily identifiable. Overall, this system has enabled a real-time and quantitative measurement of a large number of ADME samples, providing a rapid evaluation of clinically important drug-drug interaction potential and drug metabolic stability.
引用
收藏
页码:761 / 772
页数:12
相关论文
共 50 条
  • [1] Automated high throughput ADME assays for metabolic stability and cytochrome P450 inhibition profiling of combinatorial libraries
    Jenkins, KM
    Angeles, R
    Quintos, MT
    Xu, RD
    Kassel, DB
    Rourick, RA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 989 - 1004
  • [2] High-throughput cytochrome P450 inhibition assays by ultrafast gradient liquid chromatography with tandem mass spectrometry using monolithic columns
    Peng, SX
    Barbone, AG
    Ritchie, DM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (06) : 509 - 518
  • [3] High-throughput analysis of in vitro cytochrome p450 inhibition samples using mass spectrometry coupled with an integrated liquid chromatography/autosampler system
    Brown, Ann
    Bickford, Shari
    Hatsis, Panos
    Amin, Jakal
    Bell, Leslie
    Harriman, Shawn
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (08) : 1207 - 1210
  • [4] High-throughput inhibition screening of major human cytochrome P450 enzymes in vitro using liquid chromatography-tandem mass spectrometry
    Liu, KH
    Kim, MJ
    Kang, W
    Cha, IJ
    Shin, JG
    DRUG METABOLISM REVIEWS, 2004, 36 : 249 - 249
  • [5] A high-throughput inhibition screening of major human cytochrome P450 enzymes using an in vitro cocktail and liquid chromatography-tandem mass spectrometry
    Qin, Chong-Zhen
    Ren, Xian
    Tan, Zhi-Rong
    Chen, Yao
    Yin, Ji-Ye
    Yu, Jing
    Qu, Jian
    Zhou, Hong-Hao
    Liu, Zhao-Qian
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (02) : 197 - 203
  • [6] High-throughput inhibition screening of major human cytochrome P450 enzymes using an in vitro cocktail and liquid chromatography-tandem mass spectrometry
    Testino, SA
    Patonay, G
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 30 (05) : 1459 - 1467
  • [7] High-throughput screening of inhibitory potential of nine cytochrome P450 enzymes in vitro using liquid chromatography/tandem mass spectrometry
    Kim, MJ
    Kim, H
    Cha, IJ
    Park, JS
    Shon, JH
    Liu, KH
    Shin, JG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) : 2651 - 2658
  • [8] High-throughput cytochrome P450 inhibition assays using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry
    Wu, Jin
    Hughes, Christopher S.
    Picard, Pierre
    Letarte, Sylvain
    Gaudreault, Mireille
    Levesque, Jean-Francois
    Nicoll-Griffith, Deborah A.
    Bateman, Kevin P.
    ANALYTICAL CHEMISTRY, 2007, 79 (12) : 4657 - 4665
  • [9] Comparison of rapidfire® ultra high throughput MS with traditional LCMS/MS for cytochrome P450 inhibition testing
    Perloff, Elke S.
    Dehal, Shangara S.
    Mason, Andrew K.
    Blanchard, Andrew P.
    Crespi, Charles L.
    Ozbal, Can C.
    Lamarr, William A.
    Miller, Vaughn P.
    Stresser, David M.
    DRUG METABOLISM REVIEWS, 2009, 41 : 114 - 115
  • [10] HIGH-THROUGHPUT INHIBITION SCREENING OF TERPENOIDS AND FLAVONOIDS ON THE ACTIVITY OF HUMAN SIX MAJOR CYTOCHROME P450 ENZYMES USING AN IN VITRO COCKTAIL AND LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY
    Huang, Min
    He, Fan
    Deng, Ying
    Bi, Huichang
    Zhao, Lizi
    DRUG METABOLISM REVIEWS, 2007, 39 : 192 - 193