Variation in Use of Dual-Chamber Implantable Cardioverter-Defibrillators Results From the National Cardiovascular Data Registry

被引:0
|
作者
Matlock, Dan D. [1 ,2 ,3 ]
Peterson, Pamela N. [2 ,3 ,4 ]
Wang, Yongfei [5 ]
Curtis, Jeptha P. [5 ]
Reynolds, Matthew R. [6 ,7 ]
Varosy, Paul D. [2 ,8 ]
Masoudi, Frederick A. [2 ,3 ]
机构
[1] Univ Colorado Denver, Sch Med, Div Gen Internal Med, Acad Off 1,Dept Med, Aurora, CO 80045 USA
[2] Colorado Cardiovasc Outcomes Res Grp, Denver, CO USA
[3] Kaiser Permanente Colorado, Inst Hlth Res, Denver, CO USA
[4] Denver Hlth Med Ctr, Dept Med, Denver, CO USA
[5] Yale Univ, Dept Internal Med, New Haven, CT USA
[6] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiol, Boston, MA 02215 USA
[7] Boston VA Healthcare Syst, Boston, MA USA
[8] Vet Affairs Eastern Colorado Hlth Care Syst, Med Serv, Cardiol Sect, Denver, CO USA
基金
美国医疗保健研究与质量局;
关键词
REGIONAL-VARIATIONS; HOSPITAL VARIATION; ADVERSE EVENTS; HEALTH-CARE; DEVICES; COST; ASSOCIATION; PERCEPTIONS; DIFFUSION; OUTCOMES;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Among patients without an indication for a pacemaker, current evidence is inconclusive whether a dual-chamber implantable cardioverter-defibrillator (ICD) is superior to a single-chamber ICD. The current use of dual-chamber ICDs is not well characterized. Methods: We conducted a cross-sectional study exploring hospital-level variation in the use of dual-chamber ICDs across the United States. Patients receiving a primary prevention ICD from 2006 through 2009 without a documented indication for a pacemaker were included. Multivariate hierarchical logistic regression was used to explore patient, health care provider, and physician factors related to the use of a dual-chamber device. Results: Dual-chamber devices were implanted in 58% of the 87 115 patients without a pacing indication among 1293 hospitals, with hospital rates ranging from 0% in 33 centers to 100% in 109 centers. In multivariate analysis, geographic region was a strong independent predictor of dual-chamber device use, ranging from 36.4% in New England (reference region) to 66.4% in the Pacific region (odds ratio [OR], 5.25; 95% CI, 3.35-8.21). Hospital clustering was assessed using a median OR which was 3.96, meaning that 2 identical patients at different hospitals would have nearly a 4-fold difference in their chance of receiving a dual-chamber ICD. Conclusions: Use of dual-chamber ICDs for the primary prevention of sudden cardiac death among patients without an indication for permanent pacing varies markedly at the hospital level in the United States. This is a clear example of how practice can vary independent of patient factors. Arch Intern Med. 2012;172(8):634-641
引用
收藏
页码:634 / 641
页数:8
相关论文
共 50 条
  • [1] Regional Variation in the Use of Implantable Cardioverter-Defibrillators for Primary Prevention Results From the National Cardiovascular Data Registry
    Matlock, Dan D.
    Peterson, Pamela N.
    Heidenreich, Paul A.
    Lucas, F. Lee
    Malenka, David J.
    Wang, Yongfei
    Curtis, Jeptha P.
    Kutner, Jean S.
    Fisher, Elliott S.
    Masoudi, Frederick A.
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2011, 4 (01): : 114 - 121
  • [2] Dual-Chamber Implantable Cardioverter-Defibrillators for Nonpacing Indications
    Redberg, Rita F.
    ARCHIVES OF INTERNAL MEDICINE, 2012, 172 (08) : 641 - 641
  • [3] Regional Variations of Primary Prevention Implantable Cardioverter-Defibrillators: Results From the National Cardiovascular Data Registry
    Matlock, Dan D.
    Peterson, Pamela N.
    Heidenreich, Paul A.
    Lucas, F. Lee
    Malenka, David J.
    Curtis, Jeptha P.
    Wang, Yongfei
    Kutner, Jean S.
    Fisher, Elliott S.
    Masoudi, Frederick A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A130 - A130
  • [4] Possible benefits of dual-chamber implantable cardioverter-defibrillators in reducing inadequate therapy compared to conventional single-chamber implantable cardioverter-defibrillators: a clinical randomised study
    Deisenhofer, I
    Kolb, C
    Schreieck, J
    Karch, MR
    Zrenner, B
    Schmitt, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 470 - 470
  • [5] Dual-chamber rate responsive pacing increases mortality in patients with implantable cardioverter-defibrillators
    Aronow, WS
    Sukhija, R
    Sorbera, C
    Yalamanchili, K
    Cohen, M
    CHEST, 2004, 126 (04) : 824S - 824S
  • [6] Do new dual-chamber implantable cardioverter-defibrillators reduce the incidence of inadequate therapy compared to conventional single-chamber implantable cardioverter-defibrillators? A clinical randomised study
    Deisenhofer, I
    Kolb, C
    Schreieck, J
    CIRCULATION, 2000, 102 (18) : 397 - 397
  • [7] VENTRICULOATRIAL CONDUCTION IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - IMPLICATIONS FOR TACHYCARDIA DISCRIMINATION BY DUAL-CHAMBER SENSING
    LI, HG
    THAKUR, RK
    YEE, R
    KLEIN, GJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (12): : 2304 - 2306
  • [8] VENTRICULOATRIAL CONDUCTION IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - IMPLICATION FOR TACHYCARDIA DISCRIMINATION BY DUAL-CHAMBER SENSING
    LI, HG
    ZARDINI, M
    THAKUR, RK
    MORILLO, CA
    YEE, R
    KLEIN, GJ
    CIRCULATION, 1993, 88 (04) : 54 - 54
  • [9] Comparison of Inappropriate Shocks and Other Health Outcomes Between Single- and Dual-Chamber Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter-Defibrillators
    Peterson, Pamela N.
    Greenlee, Robert T.
    Go, Alan S.
    Magid, David J.
    Cassidy-Bushrow, Andrea
    Garcia-Montilla, Romel
    Glenn, Karen A.
    Gurwitz, Jerry H.
    Hammill, Stephen C.
    Hayes, John
    Kadish, Alan
    Reynolds, Kristi
    Sharma, Param
    Smith, David H.
    Varosy, Paul D.
    Vidaillet, Humberto
    Zeng, Chan X.
    Normand, Sharon-Lise T.
    Masoudi, Frederick A.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (11):
  • [10] Single-chamber versus dual-chamber implantable cardioverter defibrillators:: Indications and clinical results
    Trappe, HJ
    Achtelik, M
    Pfitzner, P
    Voigt, B
    Weismüller, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (5B): : 8D - 16D