Comparison of pre-processing methods for multiplex bead-based immunoassays

被引:13
|
作者
Rausch, Tanja K. [1 ]
Schillert, Arne [1 ]
Ziegler, Andreas [1 ,2 ,3 ]
Lueking, Angelika [4 ]
Zucht, Hans-Dieter [4 ]
Schulz-Knappe, Peter [4 ]
机构
[1] Univ Lubeck, Inst Med Biometrie & Stat, Univ Klinikum Schleswig Holstein, Campus Lubeck,Ratzeburger Allee 160, D-23562 Lubeck, Germany
[2] Univ Lubeck, Zentrum Klin Studien, Lubeck, Germany
[3] Univ KwaZulu Natal, Sch Math Stat & Comp Sci, Pietermaritzburg, South Africa
[4] Protagen AG, Dortmund, Germany
来源
BMC GENOMICS | 2016年 / 17卷
关键词
Autoantibody; Bead-based; Immunoassay; Luminex; Multiplex; Omics; Pre-processing; Protein; DNA MICROARRAY DATA; NORMALIZATION METHODS; QUALITY-CONTROL; EXPRESSION; VARIANCE; TRANSFORMATION; TESTS; PIPELINE;
D O I
10.1186/s12864-016-2888-7
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: High throughput protein expression studies can be performed using bead-based protein immunoassays, such as the Luminex (R) xMAP (R) technology. Technical variability is inherent to these experiments and may lead to systematic bias and reduced power. To reduce technical variability, data pre-processing is performed. However, no recommendations exist for the pre-processing of Luminex (R) xMAP (R) data. Results: We compared 37 different data pre-processing combinations of transformation and normalization methods in 42 samples on 384 analytes obtained from a multiplex immunoassay based on the Luminex (R) xMAP (R) technology. We evaluated the performance of each pre-processing approach with 6 different performance criteria. Three performance criteria were plots. All plots were evaluated by 15 independent and blinded readers. Four different combinations of transformation and normalization methods performed well as pre-processing procedure for this bead-based protein immunoassay. Conclusions: The following combinations of transformation and normalization were suitable for pre-processing Luminex (R) xMAP (R) data in this study: weighted Box-Cox followed by quantile or robust spline normalization (rsn), asinh transformation followed by loess normalization and Box-Cox followed by rsn.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of pre-processing methods for multiplex bead-based immunoassays
    Tanja K. Rausch
    Arne Schillert
    Andreas Ziegler
    Angelika Lüking
    Hans-Dieter Zucht
    Peter Schulz-Knappe
    [J]. BMC Genomics, 17
  • [2] Comparison of Bead-Based Fluorescence Versus Planar Electrochemiluminescence Multiplex Immunoassays for Measuring Cytokines in Human Plasma
    Guenther, Anna
    Becker, Matthias
    Goepfert, Jens
    Joos, Thomas
    Schneiderhan-Marra, Nicole
    [J]. FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [3] Bead-based immunoassays with microelectrode detection
    Svetlana Farrell
    Niina J. Ronkainen-Matsuno
    H. Brian Halsall
    William R. Heineman
    [J]. Analytical and Bioanalytical Chemistry, 2004, 379 : 358 - 367
  • [4] An integrated model for bead-based immunoassays
    Wu, Dan
    Voldman, Joel
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 154
  • [5] Bead-based immunoassays with microelectrode detection
    Farrell, S
    Ronkainen-Matsuno, NJ
    Halsall, HB
    Heineman, WR
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) : 358 - 367
  • [6] Utility of Bead-Based Multiplex Immunoassays as Screening Tests for the Diagnosis of Connective Tissue Diseases
    Murata, K.
    Snyder, M. R.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : A129 - A129
  • [7] Quantitative Bead-Based Multiplex Immunoassays for Mouse Anti-Virus Immune Response
    Zhao, Amy
    Sun, Binggang
    Lehmann, Jason
    Ji, Shaoquan
    Jiang, Weiping
    [J]. JOURNAL OF IMMUNOLOGY, 2018, 200 (01):
  • [8] Comparison study of bead-based and line-blot multiplex ANA immunoassays in the diagnosis of systemic autoimmune rheumatic diseases
    Yuan, Weiru
    Cao, Hua
    Li, Weiping
    Wu, Xinyi
    Zheng, Jie
    [J]. CLINICAL RHEUMATOLOGY, 2022, 41 (03) : 899 - 909
  • [9] Bead-based microfluidic immunoassays: The next generation
    Lim, C. T.
    Zhang, Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1197 - 1204
  • [10] Comparison study of bead-based and line-blot multiplex ANA immunoassays in the diagnosis of systemic autoimmune rheumatic diseases
    Weiru Yuan
    Hua Cao
    Weiping Li
    Xinyi Wu
    Jie Zheng
    [J]. Clinical Rheumatology, 2022, 41 : 899 - 909