A bone suppression method to improve tumour motion monitoring in intensity-based 2D/3D registration

被引:0
|
作者
Gulyas, I. [1 ]
Trnkova, P. [1 ]
Georg, D. [1 ]
Renner, A. [1 ]
机构
[1] Med Univ Vienna, Dept Radiat Oncol, Vienna, Austria
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1758
引用
收藏
页码:S1484 / S1485
页数:2
相关论文
共 50 条
  • [1] Robust and Fast Initialization for Intensity-Based 2D/3D Registration
    Shao, Zhenzhou
    Han, Jianda
    Liang, Wei
    Tan, Jindong
    Guan, Yong
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [2] A novel bone suppression algorithm in intensity-based 2D/3D image registration for real-time tumor motion monitoring: Development and phantom-based validation
    Gulyas, Ingo
    Trnkova, Petra
    Knaeusl, Barbara
    Widder, Joachim
    Georg, Dietmar
    Renner, Andreas
    MEDICAL PHYSICS, 2022, 49 (08) : 5182 - 5194
  • [3] Reproduction of forearm rotation dynamic using intensity-based biplane 2D–3D registration matching method
    Ryoya Shiode
    Satoshi Miyamura
    Arisa Kazui
    Natsuki Yamamoto
    Tasuku Miyake
    Toru Iwahashi
    Hiroyuki Tanaka
    Yoshito Otake
    Yoshinobu Sato
    Tsuyoshi Murase
    Shingo Abe
    Seiji Okada
    Kunihiro Oka
    Scientific Reports, 14
  • [4] Evaluation of an intensity-based algorithm for 2D/3D registration of natural knee videofluoroscopy data
    Postolka, Barbara
    List, Renate
    Thelen, Benedikt
    Schutz, Pascal
    Taylor, William R.
    Zheng, Guoyan
    MEDICAL ENGINEERING & PHYSICS, 2020, 77 : 107 - 113
  • [5] Hardware-assisted 2D/3D intensity-based registration for assessing patellar tracking
    Tang, TSY
    MacIntyre, NJ
    Gill, HS
    Fellows, RA
    Hill, NA
    Wilson, DR
    Ellis, RE
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 2, PROCEEDINGS, 2004, 3217 : 1095 - 1096
  • [6] Intensity-based 3D local image registration
    Song, Huajun
    Qiu, Peihua
    PATTERN RECOGNITION LETTERS, 2017, 94 : 15 - 21
  • [7] Transgraph: interactive intensity-based 2D/3D registration of X-ray and CT data
    LaRose, D
    Bayouth, J
    Kanade, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 385 - 396
  • [8] Intensity-based 2D 3D registration for lead localization in robot guided deep brain stimulation
    Hunsche, Stefan
    Sauner, Dieter
    El Majdoub, Faycal
    Neudorfer, Clemens
    Poggenborg, Joerg
    Gossmann, Axel
    Maarouf, Mohammad
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2417 - 2426
  • [9] Intensity-based femoral atlas 2D/3D registration using Levenberg-Marquardt optimisation
    Klima, Ondrej
    Kleparnik, Petr
    Spanel, Michal
    Zemcik, Pavel
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [10] Effective intensity-based 2D/3D rigid registration between fluoroscopic X-ray and CT
    Knaan, D
    Joskowicz, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 351 - 358