Agreement Between the OptoGait and Instrumented Treadmill System for the Quantification of Spatiotemporal Treadmill Running Parameters

被引:12
|
作者
Weart, Amy N. [1 ]
Miller, Erin M. [2 ]
Freisinger, Gregory M. [3 ]
Johnson, Michael R. [1 ]
Goss, Donald L. [4 ]
机构
[1] Keller Army Community Hosp, Dept Phys Therapy, West Point, NY 10996 USA
[2] Baylor Univ, Keller Army Community Hosp, Div Sports Phys Therapy Fellowship 1, West Point, NY USA
[3] US Mil Acad, Dept Civil & Mech Engn, West Point, NY 10996 USA
[4] High Point Univ, Dept Phys Therapy, High Point, NC USA
来源
关键词
gait analysis; running; spatiotemporal parameters; OptoGait; method comparision; PHOTOELECTRIC-CELL SYSTEM; GAIT; LENGTH; REPEATABILITY; RELIABILITY; VALIDITY; ANTERIOR; CONTACT; RUNNERS; CADENCE;
D O I
10.3389/fspor.2020.571385
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The measurement of spatiotemporal gait parameters is commonly utilized to assess gait in healthy and injured individuals. The OptoGait system is a portable system and can be mounted to a treadmill to collect data in a clinical, training, or research setting. The purpose of this method comparison study was to examine the agreement of spatiotemporal gait parameters calculated by the OptoGait compared to an instrumented treadmill system during running. Thirty healthy runners ran on an instrumented treadmill with the OptoGait 1-m system mounted along the treadmill platform. Spatiotemporal running variables of step rate, step length, and contact time were calculated during the final minute of treadmill running. The level of agreement between the OptoGait and treadmill was analyzed using intraclass correlation coefficients [ICC (2,3)] for step rate, step length, and contact time. Step rate and step length demonstrated excellent agreement. Contact time demonstrated good agreement. Intraclass correlation coefficients for spatiotemporal parameters ranged from 0.83 to 0.99. The OptoGait demonstrated good to excellent agreement in the evaluation of running step rate, step length, and contact time and should be considered for use in clinical, training, or research settings.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Reliability of spatiotemporal and kinetic gait parameters determined by a new instrumented treadmill system
    Reed, Lloyd F.
    Urry, Stephen R.
    Wearing, Scott C.
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [2] Reliability of spatiotemporal and kinetic gait parameters determined by a new instrumented treadmill system
    Lloyd F Reed
    Stephen R Urry
    Scott C Wearing
    BMC Musculoskeletal Disorders, 14
  • [3] Agreement between temporal and spatial gait parameters from an instrumented walkway and treadmill system at matched walking speed
    Wearing, Scott C.
    Reed, Lloyd F.
    Urry, Stephen R.
    GAIT & POSTURE, 2013, 38 (03) : 380 - 384
  • [4] Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients
    Lee, Myungmo
    Song, Changho
    Lee, Kyoungjin
    Shin, Doochul
    Shin, Seungho
    MEDICAL SCIENCE MONITOR, 2014, 20
  • [5] Validity Analysis of WalkerViewTM Instrumented Treadmill for Measuring Spatiotemporal and Kinematic Gait Parameters
    Bravi, Marco
    Massaroni, Carlo
    Santacaterina, Fabio
    Di Tocco, Joshua
    Schena, Emiliano
    Sterzi, Silvia
    Bressi, Federica
    Miccinilli, Sandra
    SENSORS, 2021, 21 (14)
  • [6] Gait analysis in multiple sclerosis: characterization of spatiotemporal parameters using an instrumented treadmill
    Kalron, A.
    Frid, L.
    Achiron, A.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 (07) : 998 - 999
  • [7] The relationship between fear of falling to spatiotemporal gait parameters measured by an instrumented treadmill in people with multiple sclerosis
    Kalron, Alon
    Achiron, Anat
    GAIT & POSTURE, 2014, 39 (02) : 739 - 744
  • [8] Instrumented Comparison of Overground and Treadmill Running in Healthy Individuals
    Willy, Richard
    Davis, Irene S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S27 - S28
  • [9] Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Ramirez-Campillo, Rodrigo
    Roche-Seruendo, Luis E.
    JOURNAL OF BIOMECHANICS, 2019, 93 : 213 - 219
  • [10] Performance determinants, running energetics and spatiotemporal gait parameters during a treadmill ultramarathon
    Howe, Christopher C. F.
    Swann, Nicola
    Spendiff, Owen
    Kosciuk, Anna
    Pummell, Elizabeth K. L.
    Moir, Hannah J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (06) : 1759 - 1771