Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units

被引:32
|
作者
Cai, Qingzhong [1 ]
Yang, Gongliu [1 ]
Song, Ningfang [1 ]
Liu, Yiliang [2 ]
机构
[1] Beihang Univ, Sch Instrument Sci & Optoelect Engn, Beijing 100191, Peoples R China
[2] Space Star Technol Co Ltd, Beijing 100101, Peoples R China
关键词
systematic calibration; ultrahigh-accuracy inertial measurement unit; error modelling; Kalman filter;
D O I
10.3390/s16060940
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inertial navigation system (INS) has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 x 10(-6)degrees/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs) using common turntables, has a great application potential in future atomic gyro INSs.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [1] Systematic Calibration method for FOG Inertial Measurement Units
    Zheng, Zhenyu
    Gao, Yanbin
    He, Kunpeng
    NANOTECHNOLOGY AND PRECISION ENGINEERING, PTS 1 AND 2, 2013, 662 : 717 - 720
  • [2] Calibration errors of high-precision inertial measurement units
    Zhang, Hong-Liang
    Wu, Yuan-Xin
    Zha, Ya-Bing
    Wu, Mei-Ping
    Hu, Xiao-Ping
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2010, 32 (01): : 142 - 146
  • [3] The static accuracy and calibration of inertial measurement units for 3D orientation
    Brodie, M. A.
    Walmsley, A.
    Page, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (06) : 641 - 648
  • [4] A VIPA spectrograph with ultra-high spectral resolution, ultra-high wavelength calibration accuracy and wide spectral range
    Zhang, Zhongnan
    Wang, Yutao
    Zhu, Xiaoming
    Lin, Dong
    He, Jinping
    Journal of Optics (United Kingdom), 2024, 26 (12):
  • [5] Dynamic calibration method of inertial measurement units
    Yu. V. Filatov
    A. M. Boronakhin
    V. B. Dao
    V. T. Le
    Microsystem Technologies, 2015, 21 : 2463 - 2467
  • [6] Dynamic calibration method of inertial measurement units
    Filatov, Yu. V.
    Boronakhin, A. M.
    Dao, V. B.
    Le, V. T.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (11): : 2463 - 2467
  • [7] Calibration Technique for Micro Inertial Measurement Units
    Yue, Fengying
    Sun, Lisen
    Zhao, Shengfei
    MECHANICAL DESIGN AND POWER ENGINEERING, PTS 1 AND 2, 2014, 490-491 : 1475 - 1480
  • [8] Calibration of High-Grade Inertial Measurement Units Using a Rate Table
    Reis, Joel
    Batista, Pedro
    Oliveira, Paulo
    Silvestre, Carlos
    IEEE SENSORS LETTERS, 2019, 3 (04)
  • [9] Moderate-coherence sensing with optical cavities: ultra-high accuracy meets ultra-high measurement bandwidth and range
    Johannes Dickmann
    Liam Shelling Neto
    Steffen Sauer
    Stefanie Kroker
    Communications Engineering, 3 (1):
  • [10] Calibration and attitude determination with redundant inertial measurement units
    Pittelkau, ME
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2005, 28 (04) : 743 - 752