RADIOBIOLOGICAL CHARACTERIZATION OF TWO THERAPEUTIC PROTON BEAMS WITH DIFFERENT INITIAL ENERGY SPECTRA USED AT THE INSTITUT CURIE PROTON THERAPY CENTER IN ORSAY

被引:65
|
作者
Calugaru, Valentin [1 ,2 ]
Nauraye, Catherine [2 ]
Noel, Georges [1 ]
Giocanti, Nicole [1 ]
Favaudon, Vincent [1 ]
Megnin-Chanet, Frederique [1 ]
机构
[1] Inst Curie, INSERM, U612, Ctr Univ, F-91405 Orsay, France
[2] Inst Curie, Ctr Protontherapie Orsay, Ctr Univ, F-91405 Orsay, France
关键词
Proton therapy; Spread-out Bragg peak; Relative biological efficiency; DNA double-strand break; Clustered DNA damage; RELATIVE BIOLOGICAL EFFECTIVENESS; MODEL PREDICTIONS; STRAND BREAKS; TUMOR-CELLS; DNA; RBE; RADIOTHERAPY; RADIATION; SURVIVAL; DAMAGE;
D O I
10.1016/j.ijrobp.2010.09.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Treatment planning in proton therapy uses a generic value for the relative biological efficiency (RBE) of 1.1 throughout the spread-out Bragg peak (SOBP) generated. In this article, we report on the variation of the RBE with depth in the SOBP of the 76- and 201-MeV proton beams used for treatment at the Institut Curie Proton Therapy Center in Orsay. Methods and Materials: The RBE (relative to (137)Cs gamma-rays) of the two modulated proton beams at three positions in the SOBP was determined in two human tumor cells using as endpoints clonogenic cell survival and the incidence of DNA double-strand breaks (DSBs) as measured by pulse-field gel electrophoresis without and with enzymatic treatment to reveal clustered lesions. Results: The RBE for induced cell killing by the 76-MeV beam increased with depth in the SOBP. However for the 201-MeV protons, it was close to that for (137)Cs gamma-rays and did not vary significantly. The incidence of DSBs and clustered lesions was higher for protons than for (137)Cs gamma-rays, but did not depend on the proton energy or the position in the SOBP. Conclusions: Until now, little attention has been paid to the variation of RBE with depth in the SOBP as a function of the nominal energy of the primary proton beam and the molecular nature of the DNA damage. The RBE increase in the 76-MeV SOBP implies that the tumor tissues at the distal end receives a higher biologically equivalent dose than at the proximal end, despite a homogeneous physical dose. This is not the case for the 201-MeV energy beam. The precise determination of the effects of incident beam energy, modulation, and depth in tissues on the linear energy transfer RBE relationship is essential for treatment planning. (C) 2011 Elsevier Inc.
引用
收藏
页码:1136 / 1143
页数:8
相关论文
共 11 条
  • [1] Proton beam radiotherapy for uveal melanoma: Results of curie institut-orsay proton therapy center (ICPO)
    Dendale, Remi
    Lumbroso-Le Rouic, Livia
    Noel, Georges
    Feuvret, Loic
    Levy, Christine
    Delacroix, Sabine
    Meyer, Anne
    Nauraye, Catherine
    Mazal, Alejandro
    Mammar, Hamid
    Garcia, Paul
    D'Hermies, Francois
    Frau, Eric
    Plancher, Corine
    Asselain, Bernard
    Schlienger, Pierre
    Mazeron, Jean Jacques
    Desjardins, Laurence
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03): : 780 - 787
  • [2] Involvement of the Artemis Protein in the Relative Biological Efficiency Observed With the 76-MeV Proton Beam Used at the Institut Curie Proton Therapy Center in Orsay
    Calugaru, Valentin
    Nauraye, Catherine
    Cordelieres, Fabrice P.
    Biard, Denis
    De Marzi, Ludovic
    Hall, Janet
    Favaudon, Vincent
    Megnin-Chanet, Frederqiue
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (01): : 36 - 43
  • [3] Involvement of Artemis Protein in the Relative Biological Efficiency Observed in the 76 MeV Proton Beam Used at the Institut Curie-Proton Therapy Center in Orsay (vol 90, pg 36, 2014)
    Calugaru, V
    Nauraye, C.
    Cordelieres, F. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (02): : 457 - 457
  • [4] Investigation of ectopic recurrent skull base and cervical chordomas: The Institut Curie's Proton Therapy Center experience
    Vogin, Guillaume
    Calugaru, Valentin
    Bolle, Stephanie
    George, Bernard
    Oldrini, Guillaume
    Habrand, Jean-Louis
    Mammar, Hamid
    Dendale, Remi
    Salleron, Julia
    Noel, Georges
    Feuvret, Loic
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 : E1238 - E1246
  • [5] Energy Spectra Measurements of Therapeutic Proton Beams Using Proton-Copper Activation Leading to Multiple Positron Emitting Progenies
    Nebah, P.
    Chen, Y.
    Prusator, M.
    Bae, J.
    Ahmad, S.
    Jin, H.
    Cho, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [6] Characterization of Secondary Neutron Spectra from Therapeutic Proton and Carbon Ion Beams Using PHITS Simulation
    El-Asery, Mohamed
    Sadoune, Zouhair
    El Bekkouri, Hassane
    Al Ibrahmi, El Mehdi
    Didi, Abdessamad
    Chakir, El Mahjoub
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2023, 78 (06) : 810 - 816
  • [7] Characterization of Secondary Neutron Spectra from Therapeutic Proton and Carbon Ion Beams Using PHITS Simulation
    Mohamed El-Asery
    Zouhair Sadoune
    Hassane El Bekkouri
    El Mehdi Al Ibrahmi
    Abdessamad Didi
    El Mahjoub Chakir
    Moscow University Physics Bulletin, 2023, 78 : 810 - 816
  • [8] Chromatic energy filter and characterization of laser-accelerated proton beams for particle therapy
    Hofmann, Ingo
    Meyer-ter-Vehn, Juergen
    Yan, Xueqing
    Al-Oman, Husam
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 681 : 44 - 54
  • [9] Linear energy transfer characterization of five gel dosimeter formulations for electron and proton therapeutic beams
    Valente, M.
    Chacon, D.
    Mattea, F.
    Meilij, R.
    Perez, P.
    Romero, M.
    Scarinci, I
    Vedelago, J.
    Vitullo, F.
    Wolfel, A.
    APPLIED RADIATION AND ISOTOPES, 2021, 178
  • [10] Comparison of different Monte Carlo methods of scoring linear energy transfer in modulated proton therapy beams
    Granville, D. A.
    Sawakuchi, G. O.
    MEDICAL PHYSICS, 2014, 41 (08) : 16 - 16