Overcoming foetal motion using interactive real-time magnetic resonance imaging

被引:0
|
作者
Brix, Lau [1 ,2 ]
Ringgaard, Steffen [2 ]
Sandager, Puk [3 ,4 ]
Petersen, Olav Bjorn [3 ,4 ]
Sorensen, Thomas Sangild [4 ,5 ]
Lundorf, Erik [2 ]
Stausbol-Gron, Brian [2 ]
机构
[1] Reg Midt, Dept Procurement & Clin Engn, Olof Palmes Alle 15, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, MR Res Ctr, Aarhus N, Denmark
[3] Aarhus Univ Hosp, Dept Obstet & Gynecol, Aarhus N, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus N, Denmark
[5] Aarhus Univ, Dept Comp Sci, Aarhus N, Denmark
关键词
foetal anthropometrics; foetal brain; foetal motion compensation; foetal MRI; real-time reconstruction; MRI; BRAIN; RECONSTRUCTION;
D O I
10.1111/cpf.12364
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Objective: Foetal MRI has become an established image modality in the prenatal diagnosis of CNS anomalies, but image quality can be severely affected by foetal movements. The objective was to overcome these inherent motion problems by applying interactive real-time MRI and to evaluate the diagnostic usefulness of the applied real-time MRI sequence in relation to standard protocols. Methods: Ten healthy foetuses (gestation week 21.30.5) were scanned using a system, which allowed visual feedback and interactive slice positioning in real time. The data were compared to a control group of 14 healthy foetuses (gestation week 21.00.8) who had previously been scanned using standard MRI. Comparisons were carried out by two radiologists with regard to cerebral anthropometric sizes, presence of important brain structures, degree of movement, clinical image value, image quality and ability to obtain correct slice planes. Results: Two out of eight anthropometric sizes were statistically different between the two groups. Representation of cerebral structures was found in 70-100% in the real-time group. No statistically differences were found in clinical image value and image quality. The mean ability to obtain optimal slice planes was higher in the real-time group, but it was not significant. Conclusion: Imaging of the foetal brain using the proposed interactive real-time MRI system is a promising alternative to traditional foetal MRI for anthropometrics or as a supplement for the representation of foetal brain structures in cases in which foetal motion causes challenges in relation to obtaining optimal slice planes using conventional MRI techniques.
引用
收藏
页码:717 / 722
页数:6
相关论文
共 50 条
  • [1] REAL-TIME INTERACTIVE MAGNETIC-RESONANCE-IMAGING
    HOLSINGER, AE
    WRIGHT, RC
    RIEDERER, SJ
    FARZANEH, F
    GRIMM, RC
    MAIER, JK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) : 547 - 553
  • [2] New real-time interactive cardiac magnetic resonance imaging system
    Yang, P
    Kerr, A
    Liu, A
    Liang, DH
    Hardy, C
    Meyer, C
    Macovski, A
    Pauly, J
    Hu, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 3A - 4A
  • [3] Real-Time Magnetic Resonance Imaging
    Nayak, Krishna S.
    Lim, Yongwan
    Campbell-Washburn, Adrienne E.
    Steeden, Jennifer
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 81 - 99
  • [4] Real-time filtering with sparse variations for head motion in magnetic resonance imaging
    Weller, Daniel S.
    Noll, Douglas C.
    Fessler, Jeffrey A.
    [J]. SIGNAL PROCESSING, 2019, 157 : 170 - 179
  • [5] Flexible Sensor for Real-Time Monitoring of Motion Artifacts in Magnetic Resonance Imaging
    Hu, Yiran
    Han, Chengcheng
    Huo, Xiaoqing
    Cao, Xiaole
    Chen, Yongyang
    Cao, Zhi
    Xu, Yong
    Tao, Li
    Wu, Zhiyi
    [J]. ACS SENSORS, 2024, 9 (05): : 2614 - 2621
  • [6] Nomenclature for real-time magnetic resonance imaging
    Dietz, Bryson
    Fallone, B. Gino
    Wachowicz, Keith
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1483 - 1484
  • [7] Real-time functional magnetic resonance imaging
    Cohen, MS
    [J]. METHODS, 2001, 25 (02) : 201 - 220
  • [8] New real-time interactive cardiac magnetic resonance imaging system complements echocardiography
    Yang, PC
    Kerr, AB
    Liu, AC
    Liang, DH
    Hardy, C
    Meyer, CH
    Macovski, A
    Pauly, JM
    Hu, BS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) : 2049 - 2056
  • [9] Real-time reduction of motion artefacts using k-space weighting in magnetic resonance imaging
    Sinkus, R
    Bornert, P
    [J]. PHILIPS JOURNAL OF RESEARCH, 1998, 51 (02) : 339 - 352
  • [10] An investigation of articulatory setting using real-time magnetic resonance imaging
    Ramanarayanan, Vikram
    Goldstein, Louis
    Byrd, Dani