Disinfection Mechanisms of UV Light and Ozonization

被引:0
|
作者
Wang, Yuan-Feng [1 ]
Militky, Jiri [1 ]
Periyasamy, Aravin Prince [1 ]
Venkataraman, Mohanapriya [1 ]
Baheti, Vijay [2 ]
Yang, Kai [1 ]
Hu, Shi [1 ]
Wang, Dan [1 ]
Tan, Xiao-Dong [1 ]
Yang, Tao [3 ]
Peng, Qing-Yan [1 ]
机构
[1] Tech Univ Liberec, Dept Mat Engn, Studentska 1402-2, Liberec 46117 1, Czech Republic
[2] Indian Inst Technol Delhi, Dept Text & Fibre Engn, New Delhi 110016, India
[3] Tech Univ Liberec, Inst Nanomat Adv Technol & Innovat, Liberec 46117, Czech Republic
关键词
Ultraviolet; Ozone; SARS-CoV-2; Coronaviruses; Inactivation; RESPIRATORY SYNDROME CORONAVIRUS; INACTIVATION; VIRUSES; PLASMA;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultraviolet (UV) and ozonization technology are efficient physical processes for the disinfection of bacteria and viruses. At present, due to the outbreak of the novel coronaviruses (SARS-CoV-2) around the world, it is imperative to seek effective disinfection methods for the SARS-CoV-2. In this paper, the disinfection mechanisms of UV and ozone were analyzed, and many studies on the inactivation of similar coronavirus such as SARS-CoV and MERS-CoV by UV and ozone were reviewed. The feasibility on the application of UV and ozone to inactivate SARS-CoV-2 was discussed.
引用
收藏
页码:173 / 180
页数:8
相关论文
共 50 条
  • [1] Influence of UV Light and Ozonization on Microbes
    Tan, Xiao-Dong
    Peng, Qing-Yan
    Yang, Kai
    Saskova, Jana
    Periyasamy, Aravin Prince
    Militky, Jiri
    Wiener, Jakub
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM (TBIS) PROCEEDINGS, 2020, 2020, : 159 - 166
  • [2] UV GREEN LIGHT DISINFECTION
    MORGAN, R
    DAIRY INDUSTRIES INTERNATIONAL, 1989, 54 (11) : 33 - &
  • [3] Disinfection of hospital wastewater by continuous ozonization
    Chiang, CF
    Tsai, CT
    Lin, ST
    Huo, CP
    Lo, KV
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2003, 38 (12): : 2895 - 2908
  • [4] Disinfection of Cryptosporidium parvum with polychromatic UV light
    Mofidi, AA
    Baribeau, H
    Rochelle, PA
    De Leon, R
    Coffey, BM
    Green, JF
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2001, 93 (06): : 95 - 109
  • [5] INFLUENCE OF TEMPERATURE AND UV LIGHT ON DISINFECTION WITH OZONE
    FAROOQ, S
    ENGELBRECHT, RS
    CHIAN, ESK
    WATER RESEARCH, 1977, 11 (08) : 737 - 741
  • [6] SURFACE DISINFECTION BY EXPOSURE TO GERMICIDAL UV LIGHT
    Katara, G.
    Hemvani, N.
    Chitnis, S.
    Chitnis, V.
    Chitnis, D. S.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 26 (03) : 241 - 242
  • [7] Alternative UV light sources for surface disinfection
    Skudra, Atis
    Mežule, Linda
    Spunde, Karīna
    Rēvalde, Gita
    Zajakina, Anna
    Ziņģe, Madara
    Juhna, Tālis
    Vide. Tehnologija. Resursi - Environment, Technology, Resources, 2021, 1 : 218 - 222
  • [8] UV disinfection sheds new light on ballast market
    MacKey, Thomas
    Water and Wastewater International, 2010, 25 (05):
  • [9] Comparative inactivation of adenovirus serotypes by UV light disinfection
    Nwachuku, N
    Gerba, CP
    Oswald, A
    Mashadi, FD
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (09) : 5633 - 5636
  • [10] How particles affect UV light in the UV disinfection of unfiltered drinking water
    Christensen, J
    Linden, KG
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2003, 95 (04): : 179 - 189