Ductility considerations in seismic design of reinforced concrete framebuildings according to the Eurocode 8

被引:2
|
作者
Rodrigues, Hugo [1 ]
Elawady, Mahmoud H. [2 ]
机构
[1] Polytech Inst Leiria, RISCO Sch Technol & Management, Leiria, Portugal
[2] Polytech Inst Leiria, Sch Technol & Management, Leiria, Portugal
关键词
Seismic design; Ductility; Reinforced concrete; Eurocode; 8; RC BUILDINGS; PERFORMANCE; SHEAR;
D O I
10.1007/s41062-018-0192-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Eurocode 8 included three ductility classes: ductility class high (DC H), ductility class medium (DC M) and ductility class low(DC L). The aim of the present work is to give a full analysis of the implication during the design stage of the ductility class for the reinforced concreteframe structures regarding the Eurocode 8. To carry out the proposed study, a regular RC frame building has been designed in different hazard seismic zones for the three ductility classes according to the seismic design rules mentioned in Eurocode 8. In the end, nonlinear pushover analysis was used to assess the design of the frames. The results show that DC M has a high performance close to DC H, even in the high hazard seismic zones, and the cost of DC M frame is close to the costs of DC H frame, which could be less, if the workmanship is included, because DC H will cost more for the workmanship according to its complexity of the detailing.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Ductility considerations in seismic design of reinforced concrete frame buildings according to the Eurocode 8
    Hugo Rodrigues
    Mahmoud H. Elawady
    Innovative Infrastructure Solutions, 2019, 4
  • [2] Analysis of the local ductility in reinforced concrete beams dimensioned according to Eurocode 8
    Kassoul, A.
    Bougara, A.
    Belkhatir, M.
    Ezziane, K.
    LIFE-CYCLE CIVIL ENGINEERING, 2008, : 343 - 348
  • [3] Optimum seismic design of reinforced concrete frames according to Eurocode 8 and fib Model Code 2010
    Mergos, Panagiotis E.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (07): : 1181 - 1201
  • [4] THE DESIGN OF LOCAL DUCTILITY FOR REINFORCED CONCRETE ELEMENTS BY EUROCODE 8 - CONFINEMENT EFFECTIVENESS FACTOR
    Vulinovic, Milos
    Milicevic, Ivan
    Ignjatovic, Ivan
    GRADEVNSKI MATERIJIALI I KONSTRUKCIJE-BUILDING MATERIALS AND STRUCTURES, 2019, 62 (03): : 3 - 17
  • [5] Evaluation of factors influencing the earthquake-resistant design of reinforced concrete frames according to Eurocode 8
    Zizmond, Jure
    Dolsek, Matjaz
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2016, 12 (10) : 1323 - 1341
  • [6] Seismic safety of existing reinforced concrete structures in the context of Eurocode 8 application
    Akkermann, Jan
    BAUTECHNIK, 2021, 98 (04) : 263 - 276
  • [7] Accounting for ductility and overstrength in seismic design of reinforced concrete structures
    Branci, Taieb
    Bourada, Sofiane
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 311 - 314
  • [8] DUCTILITY AND OVERSTRENGTH IN SEISMIC DESIGN OF REINFORCED-CONCRETE STRUCTURES
    MITCHELL, D
    PAULTRE, P
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1994, 21 (06) : 1049 - 1060
  • [9] Sensitivity analysis and optimum design of reinforced concrete frames according to Eurocode 2
    Martins, Alberto M. B.
    Simoes, Luis M. C.
    Negrao, Joao H. J. O.
    Lopes, Adelino, V
    ENGINEERING OPTIMIZATION, 2020, 52 (12) : 2011 - 2032
  • [10] Seismic analysis of reinforced concrete frame-wall systems considering ductility effects in accordance to Eurocode
    Kralik, Juraj
    Kralik, Juraj, Jr.
    ENGINEERING STRUCTURES, 2009, 31 (12) : 2865 - 2872