X-ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)

被引:3
|
作者
Wayne, David M. [1 ]
Stritzinger, Jared T. [2 ]
Casella, Amanda J. [3 ]
Sweet, Lucas E. [3 ]
Corbey, Jordan F. [3 ]
Garcia, Daniel J. [2 ,6 ]
Wylie, E. Miller [4 ]
Tandon, Lav [5 ]
Olson, Angela C. [4 ]
Rim, Jung Ho [4 ]
机构
[1] Alamos Natl Lab, Mat Sci & Technol, Nucl Mat Sci, MST16,MS E574, Los Alamos, NM 87545 USA
[2] Alamos Natl Lab, Actinide Mat Proc & Power, AMPP3, MS E511, Los Alamos, NM 87545 USA
[3] Pacific Northwest Natl Lab, Nucl & Radiochem Team, POB 999, Richland, WA 99352 USA
[4] Alamos Natl Lab, Actinide Analyt Chem, CAAC, MS E554, Los Alamos, NM 87545 USA
[5] Alamos Natl Lab, Met Prod, PT1, MS E551, Los Alamos, NM 87545 USA
[6] Alamos Natl Lab, Training & Miss Serv, ORI1, MS E523, Los Alamos, NM 87545 USA
关键词
Plutonium tetrafluoride; Differential scanning calorimetry; Thermal analysis; Evolved gas analysis; Annealing; Radiation damage; RADIATION-DAMAGE; THERMODYNAMIC PROPERTIES; ACCUMULATION; FLUORINATION; DIFFUSION; DIOXIDE; SALTS; OXIDE;
D O I
10.1007/s10967-021-07810-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 30 year-old PuF4 sample consisting of brown powder (PuF4-b) and pink granules (PuF4-p) was analyzed. X-ray diffraction shows the bulk is comprised of three compounds: PuF4, -PuO2, and -PuF4 center dot 1.6H(2)O. Broadening of PuF4 XRD peaks suggests possible a-damage. After annealing at 650 degrees C, crystalline PuF4 and PuO2 remain. Thermogravimetric analysis and differential scanning calorimetry-with simultaneous evolved gas analysis- of the separated PuF4-p and PuF4-b components reveal a distinct sequence of reactions. Dehydration occurs between similar to 90 and 300 degrees C. Exothermic annealing of the a-damage occurs in two stages: at 350-355 degrees C and at 555-558 degrees C. Hydrofluoric acid, fluorine and helium desorb during the first exotherm. Above 700 degrees C, PuF4 reacts with -PuO2, resulting in oxygen release and mass loss.
引用
收藏
页码:741 / 756
页数:16
相关论文
共 50 条
  • [1] X‐ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)
    David M. Wayne
    Jared T. Stritzinger
    Amanda J. Casella
    Lucas E. Sweet
    Jordan F. Corbey
    Daniel J. Garcia
    E. Miller Wylie
    Lav Tandon
    Angela C. Olson
    Jung Ho Rim
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 329 : 741 - 756
  • [2] Use of Simultaneous X-ray Diffraction and Differential Scanning Calorimetry
    Pennartz, Paul
    Ferrara, Joseph D.
    Kishi, Akira
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2010, 66 : S130 - S130
  • [3] Analysis of differential scanning calorimetry data for aged plutonium
    Chiravalle, Vincent P.
    Journal of Chemical Physics, 2024, 161 (16):
  • [4] Differential scanning calorimetry and X-ray diffraction studies of glycolipid membranes
    Ces, O
    Seddon, JM
    Templer, RH
    Mannock, DA
    McElhaney, RN
    BIOPHYSICAL CHEMISTRY: MEMBRANES AND PROTEINS, 2002, (283): : 267 - 276
  • [5] Simultaneous measurements of X-ray diffraction-differential scanning calorimetry
    Roque-Flores, Roxana Lili
    Matos, Jivaldo do Rosario
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 137 (04) : 1347 - 1358
  • [6] X-ray diffraction and differential scanning calorimetry studies of β′ → β transitions in fat mixtures
    Szydlowska-Czerniak, A
    Karlovits, G
    Lach, M
    Szlyk, E
    FOOD CHEMISTRY, 2005, 92 (01) : 133 - 141
  • [7] Characterization of dimethyldiacyloxysilanes by differential scanning calorimetry, Raman scattering and X-ray diffraction
    Pallas, P
    Wartewig, S
    Zimmermann, I
    Richter, H
    PHARMAZIE, 2000, 55 (07): : 503 - 507
  • [8] Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs
    Izabela Jendrzejewska
    Paweł Zajdel
    Ewa Pietrasik
    Zoja Barsova
    Tomasz Goryczka
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 977 - 985
  • [9] Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs
    Jendrzejewska, Izabela
    Zajdel, Pawe
    Pietrasik, Ewa
    Barsova, Zoja
    Goryczka, Tomasz
    MONATSHEFTE FUR CHEMIE, 2018, 149 (05): : 977 - 985
  • [10] A dynamic study of the formation of gas clathrate hydrates: In-situ synchrotron x-ray diffraction and differential scanning calorimetry
    Koh, CA
    Savidge, JL
    Tang, CC
    Motie, RE
    Wu, XP
    Nooney, RI
    Westacott, R
    EUROPEAN POWDER DIFFRACTION: EPDIC IV, PTS 1 AND 2, 1996, 228 : 239 - 243