Accuracy of out-of-field dose calculations by a commercial treatment planning system

被引:172
|
作者
Howell, Rebecca M. [1 ]
Scarboro, Sarah B. [1 ,2 ]
Kry, S. F. [1 ,2 ]
Yaldo, Derek Z. [1 ,2 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 23期
关键词
ANALYTICAL ANISOTROPIC ALGORITHM; ECLIPSE AAA ALGORITHM; EXPERIMENTAL VALIDATION; SECONDARY MALIGNANCIES; RADIATION-THERAPY; PHOTON; RISK; RADIOTHERAPY; BEAMS; UNCERTAINTY;
D O I
10.1088/0031-9155/55/23/S03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The dosimetric accuracy of treatment planning systems (TPSs) decreases for locations outside the treatment field borders. However, the true accuracy of specific TPSs for locations beyond the treatment field borders is not well documented. Our objective was to quantify the accuracy of out-of-field dose predicted by the commercially available Eclipse version 8.6 TPS (Varian Medical Systems, Palo Alto, CA) for a clinical treatment delivered on a Varian Clinac 2100. We calculated (in the TPS) and determined (with thermoluminescent dosimeters) doses at a total of 238 points of measurement (with distance from the field edge ranging from 3.75 to 11.25 cm). Our comparisons determined that the Eclipse TPS underestimated out-of-field doses by an average of 40% over the range of distances examined. As the distance from the treatment field increased, the TPS underestimated the dose with increasing magnitude-up to 55% at 11.25 cm from the treatment field border. These data confirm that accuracy beyond the treatment border is inadequate, and out-of-field data from TPSs should be used only with a clear understanding of this limitation. Studies that require accurate out-of-field dose should use other dose reconstruction methods, such as direct measurements or Monte Carlo calculations.
引用
收藏
页码:6999 / 7008
页数:10
相关论文
共 50 条
  • [1] The Accuracy of the Out-Of-Field Dose Calculations of a Commercial Treatment Planning System
    Wang, L.
    Ding, G.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] The accuracy of the out-of-field dose calculations using a model based algorithm in a commercial treatment planning system
    Wang, Lilie
    Ding, George X.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : N113 - N128
  • [4] Assessment of accuracy of out-of-field dose calculations by TiGRT treatment planning system in radiotherapy
    Toossi, Mohammad Taghi Bahreyni
    Soleymanifard, Shokouhozaman
    Farhood, Bagher
    Mohebbi, Shokoufeh
    Davenport, David
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (03) : 634 - 639
  • [5] A Method to Accurately Estimate Out-Of-Field Organ Dose Based On the Calculations From a Commercial Treatment Planning System
    wang, L.
    Ding, G.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2911 - 2911
  • [6] Estimating the uncertainty of calculated out-of-field organ dose from a commercial treatment planning system
    Wang, Lilie
    Ding, George X.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 319 - 324
  • [7] Dose calculation accuracy of radiotherapy treatment planning systems in out-of-field regions
    Farhood, B.
    Ghorbani, M.
    [J]. Journal of Biomedical Physics and Engineering, 2019, 9 (02): : 133 - 136
  • [8] Out-of-Field Dose Calculation by a Commercial Treatment Planning System and Comparison by Monte Carlo Simulation for Varian TrueBeam®
    Shine, N. S.
    Paramu, Raghukumar
    Gopinath, M.
    Bos, R. C. Jaon
    Jayadevan, P. M.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 156 - 175
  • [9] Accuracy of out-of-field dose calculation of tomotherapy and cyberknife treatment planning systems: A dosimetric study
    Schneider, Uwe
    Haelg, Roger A.
    Hartmann, Matthias
    Mack, Andreas
    Storelli, Fabrizio
    Joosten, Andreas
    Moeckli, Raphael
    Besserer, Juergen
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (03): : 211 - 215
  • [10] Study of out-of-field dose in photon radiotherapy: A commercial treatment planning system versus measurements and Monte Carlo simulations
    Sanchez-Nieto, B.
    Medina-Ascanio, K. N.
    Rodriguez-Mongua, J. L.
    Doerner, E.
    Espinoza, I
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4616 - 4625